The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Efficacy of Infrared Vein Visualization versus Standard Technique for Peripheral Venous Cannulation in Infant and Toddler Populations: A Randomized Study
Open accessAbstract
Establishing intravenous (IV) access in younger patient populations via the traditional cannulation technique for procedures requiring anesthesia is often challenging. Infrared (IR) vein visualization is a modality that aids venous cannulation; however, few reports of this technique exist in the infant and toddler population. The primary aim of this study was to compare the efficacy of IR vein visualization to the standard cannulation technique for obtaining peripheral IV access in infant and toddler populations. Following Institutional Review Board (IRB) approval and written informed consent, children were randomly assigned to either a standard cannulation technique group or an IR vein visualization device group for venous cannulation. The primary outcome variable was the success rate of IV cannulation, and the secondary variables were the total number of attempts and the time to successful cannulation. No difference was noted between either group for first-attempt success rate (standard versus IR: 61.25% vs. 54.4%; p = 0.4) or time to establish IV cannulation (standard versus IR: median [interquartile range], 40 s [24–120] vs. 53 s [26–106]; p = 0.55). The anesthesiologist’s grading of the anticipated difficulty of IV cannulation was a significant predictor of cannulation success (p = 0.0016). Our study demonstrated no significant benefit in utilizing the IR vein visualization device in terms of the overall success rate, number of attempts, and time to establish successful IV cannulation when compared to the standard technique. However, in difficult IV access situations, this device proved to be a valuable rescue adjunct.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Economic analysis revealed favorable cost-effectiveness for NIR devices, with lower initial costs ($1500–$8000) [9] enabling faster return on investment.”
From Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis (2026) · cites this paper as [9]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Break-even occurred within 4–8 months [9] for moderate-volume centers, making NIR devices accessible to smaller healthcare facilities (Table 1 and Table 2).”
From Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis (2026) · cites this paper as [9]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Doniger, S. J., Ishimine, P., Fox, J. C., & Kanegaye, J. T. (2009) · Pediatric Emergency Care · doi:10.1097/pec.0b013e31819a8946 · Cited by 242 · cited 1×
“Recently, the ultrasound technique for establishing IV access has achieved popularity [19].”
BackgroundConsensus statement on clear fluids fasting for elective pediatric general anesthesia
Thomas, M., Morrison, C., Newton, R., & Schindler, E. (2018) · Pediatric Anesthesia · doi:10.1111/pan.13370 · Cited by 227 · cited 2×
“These factors were highlighted in recent literature suggesting a change in guidelines to one hour for clear fluids [18].”
BackgroundDifficult Venous Access in Children: Taking Control
Kuensting, L. L., DeBoer, S. L., Holleran, R. S., Shultz, B. L., Steinmann, R. A., & Venella, J. (2009) · Journal of Emergency Nursing · doi:10.1016/j.jen.2009.01.014 · Cited by 127 · cited 1×
“Our study corroborates the findings of previous reports on the efficacy of the IR vein visualization device [4,12].”
ResultComparing peripheral venous access between obese and normal weight children
Nafiu, O. O., Burke, C. N., Cowan, A., TUTUO, N., MACLEAN, S., & Tremper, K. K. (2009) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2009.03198.x · Cited by 123 · cited 1×
“Due to increased body fat and patterns of distribution, IV placement is challenging in the younger pediatric population [7].”
BackgroundVeinViewer‐assisted Intravenous Catheter Placement in a Pediatric Emergency Department
Chapman, L. L., Sullivan, B., Pacheco, A. L., Draleau, C. P., & Becker, B. M. (2011) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2011.01155.x · Cited by 81 · cited 1×
“Perhaps this may be attributed to anesthesia-induced vasodilatation, with the ability to better identify venous structures compared to studies conducted in non-anesthetized children [11,15].”
de Graaff, J. C., Cuper, N. J., Mungra, R. A. A., Vlaardingerbroek, K., Numan, S. C., & Kalkman, C. J. (2013) · Anaesthesia · doi:10.1111/anae.12294 · Cited by 81 · cited 1×
“Most studies on transillumination techniques included patients from a wide age group [2,4–6] and failed to report superiority over the traditional cannulation technique [2,4,5].”
BackgroundKaddoum, R. N., Anghelescu, D. L., Parish, M. E., Wright, B. B., Trujillo, L., Wu, J., Wu, Y., & Burgoyne, L. L. (2012) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2012.03896.x · Cited by 80 · cited 4×
“Most studies on transillumination techniques included patients from a wide age group [2,4–6] and failed to report superiority over the traditional cannulation technique [2,4,5].”
BackgroundInfluentialSchults, J. A., Kleidon, T. M., Gibson, V., Ware, R. S., Monteagle, E., Paterson, R., Charles, K. R., Keys, A., McBride, C. A., McTaggart, S. J., et al. (2022) · BMC Health Services Research · doi:10.1186/s12913-022-07605-2 · Cited by 56 · cited 2×
“Though Children 2023 , 10 , 1652 2 of 9 age [1,8] is a known risk factor for difficult IV access and a predictive factor included in the difficult intravenous access (DIVA) score [8,9], few studies have focused on the use of this device exclusively in infant and toddler populations [2,8].”
BackgroundResultvan der Woude, O. C. P., Cuper, N. J., Getrouw, C., Kalkman, C. J., & de Graaff, J. C. (2013) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e31828e5bde · Cited by 47
Near-Infrared Imaging in Intravenous Cannulation in Children: A Cluster Randomized Clinical Trial
Cuper, N. J., de Graaff, J. C., Verdaasdonk, R. M., & Kalkman, C. J. (2012) · PEDIATRICS · doi:10.1542/peds.2012-0968 · Cited by 40 · cited 4×
“Most studies on transillumination techniques included patients from a wide age group [2,4–6] and failed to report superiority over the traditional cannulation technique [2,4,5].”
BackgroundResultInfluential
Cited by
Corneanu, L. E., Petriș, O. R., Lionte, C., Sîngeap, M. S., Coșovanu, E. O., Grigolo, S., & Șova, I. A. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14186397 · Cited by 6
“Near-infrared-based devices project an image of the subcutaneous vasculature onto the skin, aiding clinicians in choosing the optimal puncture site and reducing the number of failed attempts [7,8].”
Sayed, S., Sadek, B. R. A., & Said, R. R. E. (2025) · BMJ Paediatrics Open · doi:10.1136/bmjpo-2025-003425 · Cited by 2
“Future research should focus on evaluating long-term outcomes, cost-effectiveness and the feasibility of integrating this technology into standard neonatal care protocols.”
Karaarslan, D., Ergın, D., Bal, A., & Utar, A. (2025) · International Emergency Nursing · doi:10.1016/j.ienj.2025.101613 · Cited by 2
Strategies to Address Difficult Venous Access in Blood Sampling: A Comprehensive Meta-Analysis
Mussa, B., Passarella, G., Marchese, M., & Defrancisco, B. (2026) · Medicina · doi:10.3390/medicina62030604 · Cited by 2
AI-Based Visibility Scoring for NIR Vein Images: A Software Prototype for IV Insertion Support
Sabyani, R., Zakri, A. K., Alqahtani, S., Alharbi, S. B., Alkadi, S., & Alsamri, J. (2025) · International Conference on Interdisciplinary Computer Science and Engineering (ICICSE) · doi:10.1109/icicse67247.2025.11390790 · Cited by 1
Metadata
- Authors
- Fehr, G., Rigali, M., Weller, G., Grap, S. M., Coleman, M., Parekh, U., Chinchilli, V. M., & Dalal, P. G.
- Affiliations
- Children's Hospital of The King's Daughters (US)
- Virginia Commonwealth University (US)
- Pennsylvania State University (US)
- Corresponding author
- Dalal, Priti G.
- Venue
- Children
- Publisher
- MDPI AG
- Published
- 2023-10-05
- Volume
- 10
- Issue
- 10
- Pages
- 1652
- ISSN
- 2227-9067 (ISSN-L)
- PMC
- PMC10605772
- OpenAlex
- W4387369959
- Cited by
- 5
- References
- 19
- Citations by year
- 2026: 1 · 2025: 4
- FWCI
- 1.69
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Children (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Department of Anesthesiology, Penn State Health
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Physical Sciences › Engineering › Biomedical Engineering › Intravenous Infusion Technology and Safety
- Health Sciences › Medicine › Anesthesiology and Pain Medicine › Anesthesia and Sedative Agents
- Keywords
- peripheral venous cannulation, intravenous access, infants, toddlers, pediatric anesthesia, cannulation success rate, difficult venous access
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficacy of Infrared Vein Visualization versus Standard Technique for Peripheral Venous Cannulation in Infant and Toddler Populations: A Randomized Study. https://app.cochat.ai/papers/10.3390/children10101652
- The paper
- Fehr, G., Rigali, M., Weller, G., Grap, S. M., Coleman, M., Parekh, U., Chinchilli, V. M., & Dalal, P. G. (2023). Efficacy of Infrared Vein Visualization versus Standard Technique for Peripheral Venous Cannulation in Infant and Toddler Populations: A Randomized Study. Children. https://doi.org/10.3390/children10101652
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.
