Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 298

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Robotic resection compared with laparoscopic rectal resection for cancer: systematic review and meta‐analysis of short‐term outcome

Trastulli, S., Farinella, E., Cirocchi, R., Cavaliere, D., Avenia, N., Sciannameo, F., Gullà, N., Noya, G., Boselli, C. · 2012 · Colorectal Disease

Abstract

Aim The study aimed to compare robotic rectal resection with laparoscopic rectal resection for cancer. Robotic surgery has been used successfully in many branches of surgery but there is little evidence in the literature on its use in rectal cancer. Methods We performed a systematic review of the available literature in order to evaluate the feasibility, safety and effectiveness of robotic versus laparoscopic surgery for rectal cancer. We compared robotic and laparoscopic surgery with respect to twelve end‐points including operative and recovery outcomes, early postoperative mortality and morbidity, and oncological parameters. A subgroup analysis of patients undergoing full‐robotic or robot‐assisted rectal resection and robotic total mesorectal excision was carried out. All aspects of Cochrane Handbook for systematic reviews and Preferred Reporting Items for Systematic Reviews and Metanalysis (PRISMA) statement were followed to conduct this systematic review. Comprehensive electronic search strategies were developed using the following electronic databases: PubMed, EMBASE, OVID, Medline, Cochrane Database of Systematic Reviews, EBM reviews and CINAHL. Randomized and nonrandomized clinical trials comparing robotic and laparoscopic resection for rectal cancer were included. No language or publication status restrictions were imposed. A data‐extraction sheet was developed based on the data extraction template of the Cochrane Group. The statistical analysis was performed using the odd ratio (OR) for categorical variables and the weighted mean difference (WMD) for continuous variables. Results Eight non randomized studies were identified that included 854 patients in total, 344 (40.2%) in the robotic group and 510 (59.7%) in the laparoscopic group. Meta‐analysis suggested that the conversion rate to open surgery in the robotic group was significantly lower than that with laparoscopic surgery (OR = 0.26, 95% CI: 0.12–0.57, P = 0.0007). There were no significant differences in operation time, length of hospital stay, time to resume regular diet, postoperative morbidity and mortality, and the oncological accuracy of resection. Conclusion Robotic surgery for rectal cancer has a lower conversion rate and a similar operative time compared with laparoscopic surgery, with no difference in recovery, oncological and postoperative outcomes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1463-1318.2011.02907.x

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 298

Metadata

Authors
Trastulli, S., Farinella, E., Cirocchi, R., Cavaliere, D., Avenia, N., Sciannameo, F., Gullà, N., Noya, G., & Boselli, C.
Venue
Colorectal Disease
Publisher
Wiley
Published
2012-03-05
Volume
14
Issue
4
Pages
e134-56
ISSN
  • 1462-8910 (ISSN-L)
  • 1463-1318
OpenAlex
W2107594724
Cited by
298
References
31
FWCI
2.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robotic resection compared with laparoscopic rectal resection for cancer: systematic review and meta‐analysis of short‐term outcome. https://app.cochat.ai/papers/10.1111/j.1463-1318.2011.02907.x
The paper
Trastulli, S., Farinella, E., Cirocchi, R., Cavaliere, D., Avenia, N., Sciannameo, F., Gullà, N., Noya, G., & Boselli, C. (2012). Robotic resection compared with laparoscopic rectal resection for cancer: systematic review and meta‐analysis of short‐term outcome. Colorectal Disease. https://doi.org/10.1111/j.1463-1318.2011.02907.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.