Real‐time elastography for detecting prostate cancer: preliminary experience
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess the use of real‐time elastography (RTE) for detecting prostate cancer in patients scheduled for radical prostatectomy (RP), as most solid tumours differ in their consistency from the deriving tissue, and RTE might offer a new tool for cancer detection. PATIENTS AND METHODS: We examined 15 patients (mean age 56 years, sd 6.2, range 46–71) with RTE, using an ultrasonography (US) system with a 7.5‐MHz transrectal probe as a transducer. RTE is capable of visualizing displacements between pairs of US images of tissues when placed under axial compression. The stiffness of the lesion was displayed from blue (soft) to black (hard). Hard lesions with a diameter of ≥ 5 mm were considered as malignant. All patients had the diagnosis of prostate cancer confirmed by biopsy and had a mean (range) prostate specific antigen (PSA) level of 4.6 (1.4–16.1) ng/mL; all were scheduled for RP. US was performed by two investigators and interpreted by consensus. Cancer location and size was determined in the RTE mode only. One pathologist classified tumour location, grade and stage. The RTE findings were compared with the pathological findings. RESULTS: There were no major complications during RP in any patient; all had a pT2 tumour on histopathological examination, the Gleason score was 5–9 and the mean (range) tumour size 1.1 (0.6–2.5) cm. Thirty‐five foci of prostate cancer were present at the pathological evaluation; multiple foci were found in 11 of the 15 glands. RTE detected 28 of 35 cancer foci (sensitivity 80%). The per‐patient analysis showed that RTE detected at least one cancer area in each of the 15 patients. Only four sites with false‐positive findings on RTE and no histopathological correlation were detected; these findings were obtained in the first five patients (period of learning). CONCLUSIONS: RTE can be used to visualize differences in tissue elasticity. Our results show that RTE allows the detection of prostate cancer and estimation of tumour location and size. RTE of the prostate is a new imaging method with great potential for detecting prostate cancer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Elastography: A quantitative method for imaging the elasticity of biological tissues
Ophir, J. (1991) · Ultrasonic Imaging · doi:10.1016/0161-7346(91)90079-w · Cited by 3,776
Elastic Moduli of Breast and Prostate Tissues under Compression
Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998) · Ultrasonic Imaging · doi:10.1177/016173469802000403 · Cited by 1,703
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Pesavento, A., Perrey, C., Krueger, M., & Ermert, H. (1999) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.796111 · Cited by 296
INITIAL EXPERIENCES WITH REAL-TIME ELASTOGRAPHY GUIDED BIOPSIES OF THE PROSTATE
KÖNIG, K., SCHEIPERS, U., PESAVENTO, A., LORENZ, A., ERMERT, H., & SENGE, T. (2005) · Journal of Urology · doi:10.1097/01.ju.0000162043.72294.4a · Cited by 262
Self-citationElastography in the Detection of Prostatic Cancer
Cochlin, D. L., Ganatra, R. H., & Griffiths, D. F. R. (2002) · Clinical Radiology · doi:10.1053/crad.2002.0989 · Cited by 253
Saturation Technique Does Not Improve Cancer Detection as an Initial Prostate Biopsy Strategy
Jones, J. S., Patel, A., Schoenfield, L., Rabets, J. C., Zippe, C. D., & Magi-Galluzzi, C. (2006) · Journal of Urology · doi:10.1016/s0022-5347(05)00211-9 · Cited by 210
Frey, H. (2003) · Der Radiologe · doi:10.1007/s00117-003-0943-2 · Cited by 204
Reduction of Image Noise in Elastography
Céspedes, I., & Ophir, J. (1993) · Ultrasonic Imaging · doi:10.1177/016173469301500202 · Cited by 199
Dhingsa, R., Qayyum, A., Coakley, F. V., Lü, Y., Jones, K. D., Swanson, M. G., Carroll, P. R., Hricak, H., & Kurhanewicz, J. V. (2004) · Radiology · doi:10.1148/radiol.2301021562 · Cited by 90
Halpern, E. J., McCue, P. A., Aksnes, A., Hagen, E. K., Frauscher, F., & Gomella, L. G. (2002) · Radiology · doi:10.1148/radiol.2222010582 · Cited by 85
Self-citationDirected Biopsy During Contrast-Enhanced Sonography of the Prostate
Halpern, E. J., Frauscher, F., Rosenberg, M., & Gomella, L. G. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.178.4.1780915 · Cited by 81
Self-citationElastographic Dynamic Range Expansion Using Variable Applied Strains
Konofagou, E. E., Ophir, J., Kallel, F., & Varghese, T. (1997) · Ultrasonic Imaging · doi:10.1177/016173469701900205 · Cited by 54
Prostate cancer: epidemiology, screening, and biomarkers.
Chodak, G. W. (2006) · Europe PMC (PubMed Central) · Cited by 46
Cited by
Cosgrove, D., Piscaglia, F., Bamber, J., Bojunga, J., Correas, J.-M., Gilja, O., Klauser, A., Sporea, I., Calliada, F., Cantisani, V., et al. (2013) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/s-0033-1335375 · Cited by 955
Fass, L. (2008) · Molecular Oncology · doi:10.1016/j.molonc.2008.04.001 · Cited by 822
Ultrasound elastography for musculoskeletal applications
Drakonaki, E. E., Allen, G. M., & Wilson, D. J. (2012) · The British Journal of Radiology · doi:10.1259/bjr/93042867 · Cited by 385
Săftoiu, A., Gilja, O. H., Sidhu, P. S., Dietrich, C. F., Cantisani, V., Amy, D., Bachmann-Nielsen, M., Bob, F., Bojunga, J., Brock, M., et al. (2019) · Ultraschall in der Medizin - European Journal of Ultrasound · doi:10.1055/a-0838-9937 · Cited by 320
Barr, R. G., Cosgrove, D., Brock, M., Cantisani, V., Correas, J. M., Postema, A. W., Salomon, G., Tsutsumi, M., Xu, H.-X., & Dietrich, C. F. (2017) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2016.06.020 · Cited by 259
Metadata
- Authors
- Pallwein, L., Mitterberger, M., Struve, P., Pinggera, G., Horninger, W., Bartsch, G., Aigner, F., Lorenz, A., Pedross, F., & Frauscher, F.
- Venue
- BJU International
- Publisher
- Wiley
- Published
- 2007-05-03
- Volume
- 100
- Issue
- 1
- Pages
- 42-46
- ISSN
- 1464-4096 (ISSN-L)
- 1464-410X
- OpenAlex
- W2149700494
- Cited by
- 179
- References
- 14
- FWCI
- 9.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.