Elastic Moduli of Breast and Prostate Tissues under Compression
Abstract
To evaluate the dynamic range of tissue imaged by elastography, the mechanical behavior of breast and prostate tissue samples subject to compression loading has been investigated. A model for the loading was validated and used to guide the experimental design for data collection. The model allowed the use of small samples that could be considered homogeneous; this assumption was confirmed by histological analysis. The samples were tested at three strain rates to evaluate the viscoelastic nature of the material and determine the validity of modeling the tissue as an elastic material for the strain rates of interest. For loading frequencies above 1 Hz, the storage modulus accounted for over 93 percent of the complex modulus. The data show that breast fat tissue has a constant modulus over the strain range tested while the other tissues have a modulus that is dependent on the strain level. The fibrous tissue samples from the breast were found to be 1 to 2 orders of magnitude stiffer than fat tissue. Normal glandular breast tissue was found to have an elastic modulus similar to that of fat at low strain levels, but the modulus of the glandular tissue increased by an order of magnitude above fat at high strain levels. Carcinomas from the breast were stiffer than the other tissues at the higher strain level; intraductal in situ carcinomas were like fat at the low strain level and much stiffer than glandular tissue at the high strain level. Infiltrating ductal carcinomas were much stiffer than any of the other breast tissues. Normal prostate tissue has a modulus that is lower than the modulus of the prostate cancers tested. Tissue from prostate with benign prostatic hyperplasia (BPH) had modulus values significantly lower than normal tissue. There was a constant but not significant difference in the modulus of tissues taken from the anterior and posterior portions of the gland.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Matrix Crosslinking Forces Tumor Progression by Enhancing Integrin Signaling
Levental, K. R., Yu, H., Kass, L., Lakins, J. N., Egeblad, M., Erler, J. T., Fong, S. F. T., Csiszar, K., Giaccia, A., Weninger, W., et al. (2009) · Cell · doi:10.1016/j.cell.2009.10.027 · Cited by 4,101
Transient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Breast Disease: Clinical Application of US Elastography for Diagnosis
Itoh, A., Ueno, E., Tohno, E., Kamma, H., Takahashi, H., Shiina, T., Yamakawa, M., & Matsumura, T. (2006) · Radiology · doi:10.1148/radiol.2391041676 · Cited by 1,640
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Elastography: Imaging the elastic properties of soft tissues with ultrasound
Ophir, J., Alam, S. K., Garra, B. S., Kallel, F., Konofagou, E. E., Krouskop, T., Merritt, C. R. B., Righetti, R., Souchon, R., Srinivasan, S., et al. (2002) · Journal of Medical Ultrasonics · doi:10.1007/bf02480847 · Cited by 366
Self-citation
Metadata
- Authors
- Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T.
- Venue
- Ultrasonic Imaging
- Publisher
- SAGE Publications
- Published
- 1998-10
- Volume
- 20
- Issue
- 4
- Pages
- 260-274
- ISSN
- 0161-7346 (ISSN-L)
- 1096-0910
- OpenAlex
- W2071027495
- Cited by
- 1,703
- References
- 0
- FWCI
- 12.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Elastic Moduli of Breast and Prostate Tissues under Compression. https://app.cochat.ai/papers/10.1177/016173469802000403
- The paper
- Krouskop, T. A., Wheeler, T. M., Kallel, F., Garra, B. S., & Hall, T. (1998). Elastic Moduli of Breast and Prostate Tissues under Compression. Ultrasonic Imaging. https://doi.org/10.1177/016173469802000403
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.