CoChat

Assessment of Glucose Turnover Rates in Euglycaemic Clamp Studies using Primed‐constant [3‐3H]‐glucose Infusion and Labelled or Unlabelled Glucose Infusates

Hother‐Nielsen, O., Møngel, A., Møller, J., Rasmussen, O., Schmitz, O., Beck‐Nielsen, H. · 1992 · Diabetic Medicine
Cited by 56

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Underestimation of glucose turnover rates has been a problem in clamp studies using primed‐constant [3‐3 H]‐glucose infusion technique. Due to slow mixing in interstitial compartments concealed specific activity gradients may arise between plasma and interstitial compartments during intravenous unlabelled glucose infusion. Such specific activity gradients, however, can be prevented if plasma specific activity is maintained constant. Two euglycaemic clamp studies (insulin infusion 40 mU m−2 min−1) were performed in six lean normal subjects. Using conventional unlabelled glucose infusates plasma specific activity declined by 74%, tracer determined glucose appearance was smaller than actual glucose infusion rates (317 ± 11 vs 366 ± 15 mg m−2 min−1, p< 0.001), and erroneous negative values were calculated for glucose production (‐49 ± 7 mg m−2 min−1). Average underestimation during the first 2 h correlated with glucose infusion rates (r = 0.88, p < 0.02). In contrast, when plasma specific activity was maintained constant, using appropriately labelled glucose infusates, tracer determined glucose appearance and glucose infusion rates were similar (385 ± 16 vs 385 ± 17 mg m−2 min−1), and negative errors for glucose production were avoided. In conclusion, using unlabelled glucose infusates, as in previous studies, suppression of glucose production is overestimated and stimulation of glucose utilization is underestimated. As errors were greater with larger glucose infusions, the mistakes may have been greatest in insulin sensitive control subjects, and smaller in insulin resistant subjects. Therefore, re‐evaluation of hepatic insulin sensitivity seems appropriate in diabetes, obesity, and other insulin resistant states.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-5491.1992.tb01903.x

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 56

Metadata

Authors
Hother‐Nielsen, O., Møngel, A., Møller, J., Rasmussen, O., Schmitz, O., & Beck‐Nielsen, H.
Venue
Diabetic Medicine
Publisher
Wiley
Published
1992-11
Volume
9
Issue
9
Pages
840-849
ISSN
  • 0742-3071 (ISSN-L)
  • 1464-5491
OpenAlex
W2028935290
Cited by
56
References
7
FWCI
2.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of Glucose Turnover Rates in Euglycaemic Clamp Studies using Primed‐constant [3‐3H]‐glucose Infusion and Labelled or Unlabelled Glucose Infusates. https://app.cochat.ai/papers/10.1111/j.1464-5491.1992.tb01903.x
The paper
Hother‐Nielsen, O., Møngel, A., Møller, J., Rasmussen, O., Schmitz, O., & Beck‐Nielsen, H. (1992). Assessment of Glucose Turnover Rates in Euglycaemic Clamp Studies using Primed‐constant [3‐3H]‐glucose Infusion and Labelled or Unlabelled Glucose Infusates. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.1992.tb01903.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.