CoChat

Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review

Hoeks, L. B. E. A., Greven, W. L., de Valk, H. W. · 2011 · Diabetic Medicine
Cited by 88

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

AIMS: This study reviews the effect of real-time continuous glucose monitoring systems in diabetes management. METHODS: A systematic search was performed in PubMed/MEDLINE and EMBASE for randomized controlled trials comparing real-time continuous glucose monitoring systems with self-monitoring blood glucose or non-real-time continuous glucose monitoring systems. RESULTS: Nine randomized controlled trials were identified. Two studies used a device which is not on the market any more. In this review we focus on the other seven studies. Performing a meta-analysis was not possible because of extensive clinical heterogeneity. Six of seven studies showed some positive effect of real-time continuous glucose monitoring systems on HbA(1c) (HbA(1c) decrease 0.3-0.7% or 3-8 mmol/mol). In some studies, this effect only was shown in subgroups (compliant adult patients). However, the size of effect may be underestimated by better-than-average results in the control group, as self-monitoring blood glucose measurements are carried out more frequently than in usual clinical practice. Despite the goal of lowering HbA(1c) , no more severe hypoglycaemic episodes were seen, except in one study. In contrast, no positive effect was shown with the real-time continuous glucose monitoring system on hypoglycaemia, but randomized controlled trials were not designed or powered to investigate this issue. Time in different glucose strata was assessed only in some trials: two of them showed a significant but small increase in time in euglycaemia. CONCLUSIONS: Current evidence shows that the real-time continuous glucose monitoring system has a beneficial effect on glycaemic control in adult diabetes patients, without an increase in the incidence of hypoglycaemia. Studies in well-selected patient groups (pregnancy, history of severe hypoglycaemias, Type 2 diabetes) are lacking.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1464-5491.2010.03177.x

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 88

Metadata

Authors
Hoeks, L. B. E. A., Greven, W. L., & de Valk, H. W.
Venue
Diabetic Medicine
Publisher
Wiley
Published
2011-03-10
Volume
28
Issue
4
Pages
386-394
ISSN
0742-3071 (ISSN-L)
OpenAlex
W1899217503
Cited by
88
References
5
FWCI
1.14
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review. https://app.cochat.ai/papers/10.1111/j.1464-5491.2010.03177.x
The paper
Hoeks, L. B. E. A., Greven, W. L., & de Valk, H. W. (2011). Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.2010.03177.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.