Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
AIMS: This study reviews the effect of real-time continuous glucose monitoring systems in diabetes management. METHODS: A systematic search was performed in PubMed/MEDLINE and EMBASE for randomized controlled trials comparing real-time continuous glucose monitoring systems with self-monitoring blood glucose or non-real-time continuous glucose monitoring systems. RESULTS: Nine randomized controlled trials were identified. Two studies used a device which is not on the market any more. In this review we focus on the other seven studies. Performing a meta-analysis was not possible because of extensive clinical heterogeneity. Six of seven studies showed some positive effect of real-time continuous glucose monitoring systems on HbA(1c) (HbA(1c) decrease 0.3-0.7% or 3-8 mmol/mol). In some studies, this effect only was shown in subgroups (compliant adult patients). However, the size of effect may be underestimated by better-than-average results in the control group, as self-monitoring blood glucose measurements are carried out more frequently than in usual clinical practice. Despite the goal of lowering HbA(1c) , no more severe hypoglycaemic episodes were seen, except in one study. In contrast, no positive effect was shown with the real-time continuous glucose monitoring system on hypoglycaemia, but randomized controlled trials were not designed or powered to investigate this issue. Time in different glucose strata was assessed only in some trials: two of them showed a significant but small increase in time in euglycaemia. CONCLUSIONS: Current evidence shows that the real-time continuous glucose monitoring system has a beneficial effect on glycaemic control in adult diabetes patients, without an increase in the incidence of hypoglycaemia. Studies in well-selected patient groups (pregnancy, history of severe hypoglycaemias, Type 2 diabetes) are lacking.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Deiss, D., Bolinder, J., Riveline, J.-P., Battelino, T., Bosi, E., Tubiana-Rufi, N., Kerr, D., & Phillip, M. (2006) · Diabetes Care · doi:10.2337/dc06-1134 · Cited by 539
Glycemic Variability: A Hemoglobin A1c–Independent Risk Factor for Diabetic Complications
Brownlee, M., & Hirsch, I. B. (2006) · JAMA · doi:10.1001/jama.295.14.1707 · Cited by 482
The effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Yoo, H. J., An, H. G., Park, S. Y., Ryu, O. H., Kim, H. Y., Seo, J. A., Hong, E. G., Shin, D. H., Kim, Y. H., Kim, S. G., et al. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.06.015 · Cited by 244
Cited by
Telemedicine and remote management of patients with heart failure
Anker, S. D., Koehler, F., & Abraham, W. T. (2011) · The Lancet · doi:10.1016/s0140-6736(11)61229-4 · Cited by 343
Ryan, R. E., Santesso, N., Lowe, D., Hill, S., Grimshaw, J. M., Prictor, M., Kaufman, C., Cowie, G., & Taylor, M. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd007768.pub3 · Cited by 273
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
The Effect of Real-Time Continuous Glucose Monitoring in Pregnant Women With Diabetes
Secher, A. L., Ringholm, L., Andersen, H. U., Damm, P., & Mathiesen, E. R. (2013) · Diabetes Care · doi:10.2337/dc12-2360 · Cited by 214
Comparative accuracy of 17 point-of-care glucose meters
Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816672237 · Cited by 127
Metadata
- Authors
- Hoeks, L. B. E. A., Greven, W. L., & de Valk, H. W.
- Venue
- Diabetic Medicine
- Publisher
- Wiley
- Published
- 2011-03-10
- Volume
- 28
- Issue
- 4
- Pages
- 386-394
- ISSN
- 0742-3071 (ISSN-L)
- OpenAlex
- W1899217503
- Cited by
- 88
- References
- 5
- FWCI
- 1.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review. https://app.cochat.ai/papers/10.1111/j.1464-5491.2010.03177.x
- The paper
- Hoeks, L. B. E. A., Greven, W. L., & de Valk, H. W. (2011). Real-time continuous glucose monitoring system for treatment of diabetes: a systematic review. Diabetic Medicine. https://doi.org/10.1111/j.1464-5491.2010.03177.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.