Structure‐function relationships in tendons: a review
Open accessThe DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Abstract
The purpose of the current review is to highlight the structure‐function relationship of tendons and related structures to provide an overview for readers whose interest in tendons needs to be underpinned by anatomy. Because of the availability of several recent reviews on tendon development and entheses, the focus of the current work is primarily directed towards what can best be described as the ‘tendon proper’ or the ‘mid‐substance’ of tendons. The review covers all levels of tendon structure from the molecular to the gross and deals both with the extracellular matrix and with tendon cells. The latter are often called ‘tenocytes’ and are increasingly recognized as a defined cell population that is functionally and phenotypically distinct from other fibroblast‐like cells. This is illustrated by their response to different types of mechanical stress. However, it is not only tendon cells, but tendons as a whole that exhibit distinct structure‐function relationships geared to the changing mechanical stresses to which they are subject. This aspect of tendon biology is considered in some detail. Attention is briefly directed to the blood and nerve supply of tendons, for this is an important issue that relates to the intrinsic healing capacity of tendons. Structures closely related to tendons (joint capsules, tendon sheaths, pulleys, retinacula, fat pads and bursae) are also covered and the concept of a ‘supertendon’ is introduced to describe a collection of tendons in which the function of the whole complex exceeds that of its individual members. Finally, attention is drawn to the important relationship between tendons and fascia, highlighted by Wood Jones in his concept of an ‘ectoskeleton’ over half a century ago – work that is often forgotten today.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gray's anatomy: the anatomical basis of clinical practice
(2005) · Choice Reviews Online · doi:10.5860/choice.43-1300 · Cited by 4,152
Role of Extracellular Matrix in Adaptation of Tendon and Skeletal Muscle to Mechanical Loading
KJÆR, M. (2004) · Physiological Reviews · doi:10.1152/physrev.00031.2003 · Cited by 1,586
PHALEN, G. S. (1966) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196648020-00001 · Cited by 1,169
Benjamin, M., Toumi, H., Ralphs, J. R., Bydder, G., Best, T. M., & Milz, S. (2006) · Journal of Anatomy · doi:10.1111/j.1469-7580.2006.00540.x · Cited by 898
Self-citationAnalysis of the tendon cell fate using Scleraxis, a specific marker for tendons and ligaments
Schweitzer, R., Chyung, J. H., Murtaugh, L. C., Brent, A. E., Rosen, V., Olson, E. N., Lassar, A., & Tabin, C. J. (2001) · Development · doi:10.1242/dev.128.19.3855 · Cited by 859
Fibrocartilage in tendons and ligaments — an adaptation to compressive load
BENJAMIN, M., & RALPHS, J. R. (1998) · Journal of Anatomy · doi:10.1046/j.1469-7580.1998.19340481.x · Cited by 787
Self-citationThe Multicomposite Structure of Tendon
Kastelic, J., Galeski, A., & Baer, E. (1978) · Connective Tissue Research · doi:10.3109/03008207809152283 · Cited by 689
Benjamin, M., & McGonagle, D. (2001) · Journal of Anatomy · doi:10.1046/j.1469-7580.2001.19950503.x · Cited by 651
Self-citationThe skeletal attachment of tendons—tendon ‘entheses’
Benjamin, M., Kumai, T., Milz, S., Boszczyk, B. M., Boszczyk, A. A., & Ralphs, J. R. (2002) · Comparative Biochemistry and Physiology Part A: Molecular & Integrative Physiology · doi:10.1016/s1095-6433(02)00138-1 · Cited by 622
Self-citationMiller, B. F., Olesen, J. L., Hansen, M., Døssing, S., Crameri, R. M., Welling, R. J., Langberg, H., Flyvbjerg, A., Kjaer, M., Babraj, J. A., et al. (2005) · The Journal of Physiology · doi:10.1113/jphysiol.2005.093690 · Cited by 610 · cited 2×
“In man, collagen synthesis in the patellar tendon increases by nearly 100% as a result of just a single bout of acute exercise, and the effect is still evident 3 days later (Miller et al. 2005).”
Background
Cited by
Docheva, D., Müller, S. A., Majewski, M., & Evans, C. H. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.11.015 · Cited by 693
Tendon Healing: Repair and Regeneration
Voleti, P. B., Buckley, M. R., & Soslowsky, L. J. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150122 · Cited by 541
Collagen type I amide I band infrared spectroscopy
de Campos Vidal, B., & Mello, M. L. S. (2011) · Micron · doi:10.1016/j.micron.2010.09.010 · Cited by 446
Pryce, B. A., Watson, S. S., Murchison, N. D., Staverosky, J. A., Dünker, N., & Schweitzer, R. (2009) · Development · doi:10.1242/dev.027342 · Cited by 420
Snedeker, J. G., & Foolen, J. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.08.032 · Cited by 377
Conversion of Mechanical Force into TGF-β-Mediated Biochemical Signals
Maeda, T., Sakabe, T., Sunaga, A., Sakai, K., Rivera, A. L., Keene, D. R., Sasaki, T., Stavnezer, E., Iannotti, J., Schweitzer, R., et al. (2011) · Current Biology · doi:10.1016/j.cub.2011.04.007 · Cited by 366
The fascia of the limbs and back – a review
Benjamin, M. (2009) · Journal of Anatomy · doi:10.1111/j.1469-7580.2008.01011.x · Cited by 345
Self-citationExtracellular matrix composition of connective tissues: a systematic review and meta-analysis
McKee, T. J., Perlman, G., Morris, M., & Komarova, S. V. (2019) · Scientific Reports · doi:10.1038/s41598-019-46896-0 · Cited by 266
The enthesis: a review of the tendon-to-bone insertion
Apostolakos, J., Durant, T. J. S., Dwyer, C. R., Russell, R. P., Weinreb, J. H., Alaee, F., Beitzel, K., McCarthy, M. B., Cote, M. P., & Mazzocca, A. D. (2019) · Muscle Ligaments and Tendons Journal · doi:10.32098/mltj.03.2014.12 · Cited by 255
Connecting muscles to tendons: tendons and musculoskeletal development in flies and vertebrates
Schweitzer, R., Zelzer, E., & Volk, T. (2010) · Development · doi:10.1242/dev.047498 · Cited by 244
“Tendons are structurally diverse, ranging from thin fascia-like layers of connective tissue to the long cord-like tendons of the limb and tail (Benjamin et al., 2008; Benjamin and Ralphs, 1997).”
BackgroundWhat is ‘fascia’? A review of different nomenclatures
Schleip, R., Jäger, H., & Klingler, W. (2012) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2012.08.001 · Cited by 197
Negative Poisson’s ratios in tendons: An unexpected mechanical response
Gatt, R., Vella Wood, M., Gatt, A., Zarb, F., Formosa, C., Azzopardi, K. M., Casha, A., Agius, T. P., Schembri-Wismayer, P., Attard, L., et al. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.06.018 · Cited by 184
“Stretching beyond this range results in permanent deformation [9].”
BackgroundThe Atypical Homeodomain Transcription Factor Mohawk Controls Tendon Morphogenesis
Liu, W., Watson, S. S., Lan, Y., Keene, D. R., Ovitt, C. E., Liu, H., Schweitzer, R., & Jiang, R. (2010) · Molecular and Cellular Biology · doi:10.1128/mcb.00207-10 · Cited by 174
Entheses: tendon and ligament attachment sites
Benjamin, M., & McGonagle, D. (2009) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2009.00906.x · Cited by 172
“The SECs asso- ciated with the insertions of the subscapularis tendon on the lesser tuberosity of the humerus and the Achilles tendon on the calcaneus are illustrated in Figs 4 and 5.”
BackgroundInfluentialSelf-citation
Metadata
- Authors
- Benjamin, M., Kaiser, E., & Milz, S.
- Venue
- Journal of Anatomy
- Publisher
- Wiley
- Published
- 2008-02-26
- Volume
- 212
- Issue
- 3
- Pages
- 211-228
- ISSN
- 0021-8782 (ISSN-L)
- 1469-7580
- OpenAlex
- W2087169849
- Cited by
- 506
- References
- 88
- FWCI
- 13.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.