Stretch‐Activated Whole‐Cell Currents in Smooth Muscle Cells from Mesenteric Resistance Artery of Guinea‐Pig
Open accessThe DOI matches its Crossref record.
Abstract
Stretch‐activated (SA) channels were studied in smooth muscle cells isolated from mesenteric resistance arteries using the whole‐cell patch‐clamp method. Membrane stretch was achieved by cell inflation after application of positive pressure through a patch electrode. In the voltage‐clamp configuration, cell inflation increased and cell deflation decreased the membrane conductance. Conductance of the evoked current depended on the increase in cross‐sectional area of the cell. The current‐voltage relationship was linear between ‐80 and 0 mV, while further hyperpolarization showed a slight inward rectification. The reversal potential of the SA current depended on the extracellular Na+ concentration, suggesting that the inward SA current was carried predominantly by Na+. The SA current was also carried by other cations, suggesting that the channel responsible for this current is a non‐selective cation channel. The permeability sequence of cations as assessed by reversal potential was as follows: K+≥ Cs+≥ Na+ > Li+. The channel was also permeable to Ca 2+. Extracellular Ca 2+ and Gd 3+ inhibited the SA current carried by monovalent cations in a concentration‐dependent manner with IC 50 (concentration giving 50% of maximal inhibition) values of 0.9 m m and 14 μ m, respectively. In the current‐clamp configuration, membrane stretch depolarized the cell, and 100 μ m Gd 3+ inhibited the stretch‐induced depolarization. The results suggest that SA cation channels exist in arterial smooth muscle cells. Activation of the channels may modify membrane potential and intracellular ionic environment, and promote stretch‐mediated cell responses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular Basis of Mechanotransduction in Living Cells
Hamill, O. P., & Martinac, B. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.2.685 · Cited by 1,134
Ryanodine Receptor Calcium Release Channels
Fill, M., & Copello, J. A. (2002) · Physiological Reviews · doi:10.1152/physrev.00013.2002 · Cited by 1,099
Signaling Mechanisms Underlying the Vascular Myogenic Response
Davis, M. J., & Hill, M. A. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.2.387 · Cited by 992
Calcium Signaling and Cardiac Arrhythmias
Landstrom, A. P., Dobrev, D., & Wehrens, X. H. T. (2017) · Circulation Research · doi:10.1161/circresaha.117.310083 · Cited by 568
TRPV2 Is a Component of Osmotically Sensitive Cation Channels in Murine Aortic Myocytes
Muraki, K., Iwata, Y., Katanosaka, Y., Ito, T., Ohya, S., Shigekawa, M., & Imaizumi, Y. (2003) · Circulation Research · doi:10.1161/01.res.0000097263.10220.0c · Cited by 521
Metadata
- Authors
- Setoguchi, M., Ohya, Y., Abe, I., & Fujishima, M.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1997-06
- Volume
- 501
- Issue
- 2
- Pages
- 343-353
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2004084338
- Cited by
- 150
- References
- 0
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stretch‐Activated Whole‐Cell Currents in Smooth Muscle Cells from Mesenteric Resistance Artery of Guinea‐Pig. https://app.cochat.ai/papers/10.1111/j.1469-7793.1997.343bn.x
- The paper
- Setoguchi, M., Ohya, Y., Abe, I., & Fujishima, M. (1997). Stretch‐Activated Whole‐Cell Currents in Smooth Muscle Cells from Mesenteric Resistance Artery of Guinea‐Pig. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.1997.343bn.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.