The DOI matches its Crossref record.
Relationship Between Venous Pressure and tissue Volume During Venous Congestion Plethysmography in Man
Open accessAbstract
Venous congestion strain‐gauge plethysmography enables the non‐invasive assessment of arterial blood flow, fluid filtration capacity (Kf), venous pressure (Pv)and isovolumetric venous pressure (Pvi)in man. One of the major assumptions of this technique, that cuff pressure (Peuff) applied to the limb equals Pv at the level of the strain gauge, was tested in this study. In nine healthy male volunteers (mean age, 29.3 ± 1.2 years) the saphenous vein was cannulated with an 18‐gauge catheter proximal to the medial malleolus. The subjects were supine and Pv was continuously measured during the application of small step (8–10 mmHg) increases in congestion Pcuff (up to 70 mm Hg). Pcuff, changes in limb circumference and Pv were recorded by computer for off‐line analysis. Since the determination of Pv is influenced by the changes in plasma oncotic pressure, venous blood samples were obtained at the start of the study, when P& was raised to 30 mmHg and again to 65 mmHg and 4 min after deflation of the cuff. The relationship between Pv and Pcuff was linear over the range of 10–70 mm Hg (n= 9, 69 measurements, slope 0.9.1, r= 0.97, P. <<0.001). The non‐invasively measured calf Pv based on the intercept of the relationship between the vascular compliance component (Vv) and Pcuff, was 8.0±0.4mmHg, which was not significantly different from the corrected invasively measured Pv value of 8.8±0.3 mmHg P= 0.08). Venous blood lactate and haemoglobin concentrations, as well as colloid osmotic pressure, total protein and albumin concentrations were unchanged throughout the protocol, whereas significant decreases in Po2 and blood glucose concentration were observed when Pcuff reached 65 mmHg. Assuming a constant oxygen consumption, this may suggest a reduction in tissue perfusion. This study demonstrates the close correlation between Pcuff and Pv in the saphenous vein. Since the small congestion Pcuff step protocol does not cause significant increase in plasma oncotic pressure, we conclude that Pv as well as Kf can be accurately determined with this venous congestion plethysmography protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neurophysiological and Computational Principles of Cortical Rhythms in Cognition
Wang, X.-J. (2010) · Physiological Reviews · doi:10.1152/physrev.00035.2008 · Cited by 1,939
Hippocampal GABAergic Inhibitory Interneurons
Pelkey, K. A., Chittajallu, R., Craig, M. T., Tricoire, L., Wester, J. C., & McBain, C. J. (2017) · Physiological Reviews · doi:10.1152/physrev.00007.2017 · Cited by 889
Cellular and Synaptic Adaptations Mediating Opioid Dependence
Williams, J. T., Christie, M. J., & Manzoni, O. (2001) · Physiological Reviews · doi:10.1152/physrev.2001.81.1.299 · Cited by 848
Causal evidence for the role of REM sleep theta rhythm in contextual memory consolidation
Boyce, R., Glasgow, S. D., Williams, S., & Adamantidis, A. (2016) · Science · doi:10.1126/science.aad5252 · Cited by 696
Regulation of the GABA cell phenotype in hippocampus of schizophrenics and bipolars
Benes, F. M., Lim, B., Matzilevich, D., Walsh, J. P., Subburaju, S., & Minns, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0703806104 · Cited by 483
Metadata
- Authors
- Christ, F., Gamble, J., Baschnegger, H., & Gartside, I. B.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1997-09
- Volume
- 503
- Issue
- 2
- Pages
- 463-467
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2150712840
- Cited by
- 182
- References
- 0
- FWCI
- 11.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship Between Venous Pressure and tissue Volume During Venous Congestion Plethysmography in Man. https://app.cochat.ai/papers/10.1111/j.1469-7793.1997.463bh.x
- The paper
- Christ, F., Gamble, J., Baschnegger, H., & Gartside, I. B. (1997). Relationship Between Venous Pressure and tissue Volume During Venous Congestion Plethysmography in Man. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.1997.463bh.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.