CoChat

Sensitivity and kinetics of mouse rod flash responses determined in vivo from paired‐flash electroretinograms

Open access
Hetling, John R., Pepperberg, David R. · 1999 · The Journal of Physiology
Cited by 86

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

1. Electroretinograms (ERGs) were recorded corneally from C57BL/6J mice using a paired-flash procedure in which a brief test flash at time zero was followed at time tprobe by a bright probe flash of fixed strength, and in which the probe response amplitude was determined at time t = tprobe + 6 ms. Probe responses obtained in a series of paired-flash trials were analysed to derive A(t), a family of amplitudes that putatively represents the massed response of the rod photoreceptors to the test flash. A central aim was to obtain a mathematical description of the normalized derived response A(t)/Amo as a function of Itest, the test flash strength. 2. With fixed tprobe (80 <= tprobe <= 1200 ms), A(t)/Amo was described by the saturating exponential function [1 - exp(-ktItest)], where kt is a time-dependent sensitivity parameter. For t = 86 ms, a time near the peak of A(t), k86 was 7.0 +/- 1.2 (scotopic cd s m-2)-1 (mean +/- s. d.; n = 4). 3. A(t)/Amo data were analysed in relation to the equation below, a time-generalized form of the above exponential function in which (k86Itest) is replaced by the product [k86Itestu(t)], and where u(t) is independent of the test flash strength. The function u(t) was modelled as the product of a scaling factor gamma, an activation term 1 - exp[-alpha(t - td)2]), and a decay term exp(-t/tauomega): A(t)/Amo = 1 - exp[-k86Itestu(t)]; u(t) = gamma(1 - exp[-alpha(t - td)2](exp(-t/tauomega) where td is a brief delay, tauomega is an exponential time constant, and alpha characterizes the acceleration of the activation term. For Itest up to approximately 2.57 scotopic cd s m-2, the overall time course of A(t) was well described by the above equation with gamma = 2.21, td = 3.1 ms, tauomega = 132 ms and alpha = 2.32 x 10-4 ms-2. An approximate halving of alpha improved the fit of the above equation to ERG a-wave and A(t)/Amo data obtained at t about 0-20 ms. 4. Kinetic and sensitivity properties of A(t) suggest that it approximates the in vivo massed photocurrent response of the rods to a test flash, and imply that u(t) in the above equation is the approximate kinetic description of a unit, i.e. single photon, response.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-7793.1999.0593v.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 86

Metadata

Authors
Hetling, J. R., & Pepperberg, D. R.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1999-04
Volume
516
Issue
2
Pages
593-609
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2044321112
Cited by
86
References
2
FWCI
1.96
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Sensitivity and kinetics of mouse rod flash responses determined in vivo from paired‐flash electroretinograms. https://app.cochat.ai/papers/10.1111/j.1469-7793.1999.0593v.x
The paper
Hetling, J. R., & Pepperberg, D. R. (1999). Sensitivity and kinetics of mouse rod flash responses determined in vivo from paired‐flash electroretinograms. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.1999.0593v.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.