CoChat

Discharge properties and recruitment of human diaphragmatic motor units during voluntary inspiratory tasks

Open access
Butler, J. E., McKenzie, D. K., Gandevia, S. C. · 1999 · The Journal of Physiology
Cited by 69

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

1. The behaviour of inspiratory motoneurones is poorly understood in humans and even for limb muscles there are few studies of motoneurone behaviour under concentric conditions. The current study assessed the discharge properties of the human phrenic motoneurones during a range of non-isometric voluntary contractions. 2. We recorded activity from 60 motor units in the costal diaphragm of four subjects using an intramuscular electrode while subjects performed a set of voluntary inspiratory contractions. These included a range of inspiratory efforts above and below the usual tidal range: breaths of different sizes (5-40 % vital capacity, VC) at a constant inspiratory flow (5 % VC s-1) and breaths of a constant size (20 % VC) at different inspiratory flows (2.5-20 % VC s-1). 3. For all the voluntary tasks, motor units were recruited throughout inspiration. For the various tasks, half-way through inspiration, 61-87 % of the sampled motor units had been recruited. 4. When the inspiratory task was deliberately altered, most single motor units began their discharge at a particular volume even when the rate of contraction had altered. 5. The initial firing frequency (median, 6.5 Hz) was consistent for tasks with a constant flow regardless of the size of the breath. However, for breaths of a constant size the initial firing frequencies increased as the inspiratory flow increased (range across tasks, 4.8-9.3 Hz). The 'final' firing frequency at the end of inspiration increased significantly above the initial frequency for each task (by 0.8-5.2 Hz) and was higher for those tasks with higher final lung volumes and higher inspiratory flows (range across tasks, 7.8-11.0 Hz). 6. There was no correlation within a task between the time of recruitment and the initial or final firing frequency for each motor unit. However, for each inspiratory task, initial and final firing frequencies were positively correlated. 7. Because the discharge of three to four units could be recorded simultaneously in a range of tasks, a quantitative 'shuffle' index was developed to describe changes in their recruitment order. Recruitment order was invariant in the task with the slowest inspiratory flow, but varied slightly, but significantly, in tasks with higher inspiratory flows. 8. The discharge rates of single motor units were compared for targeted voluntary breaths and non-targeted involuntary breaths which were matched for size. There were no significant differences in the initial or final firing frequencies, but recruitment order was not always the same in the two types of breath.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1469-7793.1999.0907p.x

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 69

Metadata

Authors
Butler, J. E., McKenzie, D. K., & Gandevia, S. C.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1999-08
Volume
518
Issue
3
Pages
907-920
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1988042261
Cited by
69
References
4
FWCI
2.10
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.