Temporal contrast sensitivity in the lateral geniculate nucleus of a New World monkey, the marmoset Callithrix jacchus
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. The temporal contrast sensitivity of koniocellular, parvocellular and magnocellular cells in the lateral geniculate nucleus (LGN) of nine adult marmosets was measured. The receptive fields of the cells were between 0.3 and 70 deg from the fovea. The stimulus was a large spatially uniform field which was modulated in luminance at temporal frequencies between 0.98 and 64 Hz. 2. For each cell group there was a gradual increase in modulation sensitivity, especially for temporal frequencies below 8 Hz, with increasing distance from the fovea. At any given eccentricity, magnocellular cells had the greatest sensitivity. In central visual field, the sensitivity of koniocellular cells lay between that of parvocellular and magnocellular cells. In peripheral visual field (above 10 deg eccentricity) koniocellular and parvocellular cells had similar sensitivity. 3. The contrast sensitivity of each cell class was dependent on the anaesthetic used. Cells from animals anaesthetized with isoflurane were less sensitive than cells from animals anaesthetized with sufentanil. This effect was more marked for temporal frequencies below 4 Hz. 4. These results are incompatible with the notion that the koniocellular pathway is functionally homologous to a sluggish, W-like pathway in other mammals. At least in terms of their temporal transfer properties, many koniocellular cells are more like parvocellular cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The contrast sensitivity of retinal ganglion cells of the cat
Enroth-Cugell, C., & Robson, J. G. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp008107 · Cited by 2,625 · cited 1×
“These studies suggest that the integrated strength or ‘volume’ (Enroth-Cugell & Robson, 1966) of centre and surround are both relatively independent of receptive field size.”
Cited by
Higher Order Visual Processing in Macaque Extrastriate Cortex
Orban, G. A. (2008) · Physiological Reviews · doi:10.1152/physrev.00008.2007 · Cited by 257
Parallel processing in the corticogeniculate pathway of the macaque monkey
Briggs, F., & Usrey, W. M. (2009) · Neuron · doi:10.1016/j.neuron.2009.02.024 · Cited by 139
Mullen, K. T., Dumoulin, S. O., & Hess, R. F. (2008) · European Journal of Neuroscience · doi:10.1111/j.1460-9568.2008.06476.x · Cited by 62
Metadata
- Authors
- Solomon, S. G., White, A. J. R., & Martin, P. R.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1999-06
- Volume
- 517
- Issue
- 3
- Pages
- 907-917
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2099126119
- Cited by
- 102
- References
- 1
- FWCI
- 3.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Temporal contrast sensitivity in the lateral geniculate nucleus of a New World monkey, the marmoset Callithrix jacchus. https://app.cochat.ai/papers/10.1111/j.1469-7793.1999.0907s.x
- The paper
- Solomon, S. G., White, A. J. R., & Martin, P. R. (1999). Temporal contrast sensitivity in the lateral geniculate nucleus of a New World monkey, the marmoset Callithrix jacchus. The Journal of Physiology. https://doi.org/10.1111/j.1469-7793.1999.0907s.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.