Effect of hypoxia on the hypopnoeic and apnoeic threshold for CO2 in sleeping humans
Open accessThe DOI matches its Crossref record.
Abstract
1. Rhythmic breathing during sleep requires that P(CO2) be maintained above a sensitive hypocapnic apnoeic threshold. Hypoxia causes periodic breathing during sleep that can be prevented or eliminated with supplemental CO(2). The purpose of this study was to determine the effect of hypoxia in changing the difference between the eupnoeic P(CO2) and the P(CO2) required to produce hypopnoea or apnoea (hypopnoea/apnoeic threshold) in sleeping humans. 2. The effect of hypoxia on eupnoeic end-tidal partial pressure of CO(2) (P(ET,CO2)) and hypopnoea/apnoeic threshold P(ET,CO2) was examined in seven healthy, sleeping human subjects. A bilevel pressure support ventilator in a spontaneous mode was used to reduce P(ET,CO2) in small decrements by increasing the inspiratory pressure level by 2 cmH2O every 2 min until hypopnoea (failure to trigger the ventilator) or apnoea (no breathing effort) occurred. Multiple trials were performed during both normoxia and hypoxia (arterial O(2) saturation, S(a,O2) = 80 %) in a random order. The hypopnoea/apnoeic threshold was determined by averaging P(ET,CO2) of the last three breaths prior to each hypopnoea or apnoea. 3. Hypopnoeas and apnoeas were induced in all subjects during both normoxia and hypoxia. Hypoxia reduced the eupnoeic P(ET,CO2) compared to normoxia (42.4 +/- 1.3 vs. 45.0 +/- 1.1 mmHg, P < 0.001). However, no change was observed in either the hypopnoeic threshold P(ET,CO2) (42.1 +/- 1.4 vs. 43.0 +/- 1.2 mmHg, P > 0.05) or the apnoeic threshold P(ET,CO2) (41.3 +/- 1.2 vs. 41.6 +/- 1.0 mmHg, P > 0.05). Thus, the difference in P(ET,CO2) between the eupnoeic and threshold levels was much smaller during hypoxia than during normoxia (-0.2 +/- 0.2 vs. -2.0 +/- 0.3 mmHg, P < 0.01 for the hypopnoea threshold and -1.1 +/- 0.2 vs. -3.4 +/- 0.3 mmHg, P < 0.01 for the apnoeic threshold). We concluded that hypoxia causes a narrowing of the difference between the baseline P(ET,CO2) and the hypopnoea/apnoeic threshold P(ET,CO2), which could increase the likelihood of ventilatory instability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pathophysiology of Sleep Apnea
Dempsey, J. A., Veasey, S. C., Morgan, B. J., & O'Donnell, C. P. (2010) · Physiological Reviews · doi:10.1152/physrev.00043.2008 · Cited by 2,243
Self-citationAinslie, P. N., & Duffin, J. (2009) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.91008.2008 · Cited by 568
Definition, discrimination, diagnosis and treatment of central breathing disturbances during sleep
Randerath, W., Verbraecken, J., Andreas, S., Arzt, M., Bloch, K. E., Brack, T., Buyse, B., De Backer, W., Eckert, D. J., Grote, L., et al. (2017) · European Respiratory Journal · doi:10.1183/13993003.00959-2016 · Cited by 354
Effect of Ventilator Mode on Sleep Quality in Critically Ill Patients
Parthasarathy, S., & Tobin, M. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200209-999oc · Cited by 324
Central Sleep Apnea in Stable Methadone Maintenance Treatment Patients
Wang, D., Teichtahl, H., Drummer, O., Goodman, C., Cherry, G., Cunnington, D., & Kronborg, I. (2005) · Chest · doi:10.1378/chest.128.3.1348 · Cited by 323
Crossing the apnoeic threshold: causes and consequences
Dempsey, J. A. (2005) · Experimental Physiology · doi:10.1113/expphysiol.2004.028985 · Cited by 280
Self-citationApnea–Hypopnea Threshold for CO 2 in Patients with Congestive Heart Failure
Xie, A., Skatrud, J. B., Puleo, D. S., Rahko, P. S., & Dempsey, J. A. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200110-022oc · Cited by 242
Self-citationDempsey, J. A., Smith, C. A., Przybylowski, T., Chenuel, B., Xie, A., Nakayama, H., & Skatrud, J. B. (2004) · The Journal of Physiology · doi:10.1113/jphysiol.2004.072371 · Cited by 222
“3C) (Xie et al. 2001; Nakayama et al. 2002).”
Self-citationEffect of Ventilatory Drive on Carbon Dioxide Sensitivity below Eupnea during Sleep
Nakayama, H., Smith, C. A., Rodman, J. R., Skatrud, J. B., & Dempsey, J. A. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2110041 · Cited by 211
Self-citationInfluence of cerebrovascular function on the hypercapnic ventilatory response in healthy humans
Xie, A., Skatrud, J. B., Morgan, B., Chenuel, B., Khayat, R., Reichmuth, K., Lin, J., & Dempsey, J. A. (2006) · The Journal of Physiology · doi:10.1113/jphysiol.2006.110627 · Cited by 158
“…response to CO2 may also help explain some of the enhanced ventilatory responsiveness to transient reductions in Pa,CO2 and the increased propensity for apnoea observed in hypoxic environments (Xie et al. 2001, 2006) and in patients with congestive heart failure (CHF) (Xie et al. 2002, 2005a).”
BackgroundSelf-citationDempsey, J. A., Xie, A., Patz, D. S., & Wang, D. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01054.2013 · Cited by 95
“assisted mechanical ventilation (48, 90), or actively, by the”
BackgroundSelf-citationSleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
Metadata
- Authors
- Xie, A., Skatrud, J. B., & Dempsey, J. A.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2001-08
- Volume
- 535
- Issue
- 1
- Pages
- 269-278
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2040620978
- Cited by
- 96
- References
- 0
- FWCI
- 1.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.