The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rapid and accurate analyses of silicon and phosphorus in plants using a portable X‐ray fluorescence spectrometer
Open accessAbstract
The elemental analysis of plant material is a frequently employed tool across biological disciplines, yet accurate, convenient and economical methods for the determination of some important elements are currently lacking. For instance, digestion-based techniques are often hazardous and time-consuming and, particularly in the case of silicon (Si), can suffer from low accuracy due to incomplete solubilization and potential volatilization, whilst other methods may require large, expensive and specialised equipment. Here, we present a rapid, safe and accurate procedure for the simultaneous, nonconsumptive analysis of Si and phosphorus (P) in as little as 0.1 g dried and ground plant material using a portable X-ray fluorescence spectrometer (P-XRF). We used certified reference materials from different plant species to test the analytical performance of P-XRF and show that the analysis suffers from very little bias and that the repeatability precision of the measurements is as good as or better than that of other methods. Using this technique we were able to process and analyse 200 ground samples a day, so P-XRF could provide a particularly valuable tool for plant biologists requiring the simultaneous nonconsumptive analysis of multiple elements, including those known to be difficult to measure such as Si, in large numbers of samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boiler deposits from firing biomass fuels
Miles, T. R., Miles, T. R., Baxter, L. L., Bryers, R. W., Jenkins, B. M., & Oden, L. L. (1996) · Biomass and Bioenergy · doi:10.1016/0961-9534(95)00067-4 · Cited by 420
Cited by
Tubana, B. S., Babu, T., & Datnoff, L. E. (2016) · Soil Science · doi:10.1097/ss.0000000000000179 · Cited by 392
Innovative methods in soil phosphorus research: A review
Kruse, J., Abraham, M., Amelung, W., Baum, C., Bol, R., Kühn, O., Lewandowski, H., Niederberger, J., Oelmann, Y., Rüger, C., et al. (2015) · Journal of Plant Nutrition and Soil Science · doi:10.1002/jpln.201400327 · Cited by 386
Deshmukh, R. K., Vivancos, J., Guérin, V., Sonah, H., Labbé, C., Belzile, F., & Bélanger, R. R. (2013) · Plant Molecular Biology · doi:10.1007/s11103-013-0087-3 · Cited by 292
Kelland, M. E., Wade, P. W., Lewis, A. L., Taylor, L. L., Sarkar, B., Andrews, M. G., Lomas, M. R., Cotton, T. E. A., Kemp, S. J., James, R. H., et al. (2020) · Global Change Biology · doi:10.1111/gcb.15089 · Cited by 281
Self-citation
Metadata
- Authors
- Reidinger, S., Ramsey, M. H., & Hartley, S. E.
- Venue
- New Phytologist
- Publisher
- Wiley
- Published
- 2012-06
- Volume
- 195
- Issue
- 3
- Pages
- 699-706
- ISSN
- 0028-646X (ISSN-L)
- 1469-8137
- OpenAlex
- W2032814532
- Cited by
- 241
- References
- 1
- FWCI
- 8.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid and accurate analyses of silicon and phosphorus in plants using a portable X‐ray fluorescence spectrometer. https://app.cochat.ai/papers/10.1111/j.1469-8137.2012.04179.x
- The paper
- Reidinger, S., Ramsey, M. H., & Hartley, S. E. (2012). Rapid and accurate analyses of silicon and phosphorus in plants using a portable X‐ray fluorescence spectrometer. New Phytologist. https://doi.org/10.1111/j.1469-8137.2012.04179.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.