Detection of and Recovery from Errors in Cardiac Interbeat Intervals
The DOI matches its Crossref record.
Abstract
An algorithm is presented for the detection and correction of errors in cardiac interbeat interval data. Detection of errors is based on the assumption that the beat‐to‐beat variation in R‐R intervals cannot exceed certain critical percentages of the preceding interval. Detected errors are corrected by merging the questionable internal with the preceding or the succeeding interval, or by subdividing it, in such manner that the resultant beat‐to‐beat variability, is minimized. The algorithm is shown mathematically to be capable of detecting errors in data with extreme beat‐to‐beat variability. Empirical experience with the algorithm suggests that it corrects errors satisfactorily under vigorous conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962
von Borell, E., Langbein, J., Després, G., Hansen, S., Leterrier, C., Marchant, J., Marchant-Forde, R., Minero, M., Mohr, E., Prunier, A., et al. (2007) · Physiology & Behavior · doi:10.1016/j.physbeh.2007.01.007 · Cited by 974
An Approach to Artifact Identification: Application to Heart Period Data
Berntson, G. G., Quigley, K. S., Jang, J. F., & Boysen, S. T. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb01982.x · Cited by 392
Lipponen, J. A., & Tarvainen, M. P. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1640306 · Cited by 364
Research methods for measurement of heart rate and respiration
Porges, S. W., & Byrne, E. A. (1992) · Biological Psychology · doi:10.1016/0301-0511(92)90012-j · Cited by 337
ACC/AHA guidelines for ambulatory electrocardiography
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00354-x · Cited by 309
Role of editing of R–R intervals in the analysis of heart rate variability
Peltola, M. A. (2012) · Frontiers in Physiology · doi:10.3389/fphys.2012.00148 · Cited by 300
Infants' Attention to Patterned Stimuli: Developmental Change From 3 to 12 Months of Age
Courage, M. L., Reynolds, G. D., & Richards, J. E. (2006) · Child Development · doi:10.1111/j.1467-8624.2006.00897.x · Cited by 244
“For offline analyses, algorithms developed by Cheung (1981) and Berntson, Quigley, Jang, and Boysen (1990) were used to identify artifacts, along with visual inspection of atypical beats in the ECG.”
MethodAnxiety, antisocial behavior, and heart rate regulation in adolescent males
Mezzacappa, E., Tremblay, R. E., Kindlon, D., Saul, J. P., Arseneault, L., Seguin, J., Pihl, R. O., & Earls, F. (1997) · Journal of Child Psychology and Psychiatry · doi:10.1111/j.1469-7610.1997.tb01531.x · Cited by 223
“These were manually corrected using accepted methods designed to maintain the integrity ofthe time series (Cheung, 1981).”
MethodThe Autonomic Differentiation of Emotions Revisited: Convergent and Discriminant Validation
Stemmler, G. (1989) · Psychophysiology · doi:10.1111/j.1469-8986.1989.tb03163.x · Cited by 189
Publication Guidelines for Heart Rate Studies in Man
Jennings, J. R., Bberg, W. K., Hutcheson, J. S., Obrist, P., Porges, S., & Turpin, G. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb03023.x · Cited by 179
HRVanalysis: A Free Software for Analyzing Cardiac Autonomic Activity
Pichot, V., Roche, F., Celle, S., Barthélémy, J.-C., & Chouchou, F. (2016) · Frontiers in Physiology · doi:10.3389/fphys.2016.00557 · Cited by 172
“First, false beats are detected using Cheung’s algorithm (Cheung, 1981): a high and low threshold are set for the relative variation in successive RR intervals ( + 32.5% and − 24.5%, respectively).”
InfluentialStuldreher, I. V., van Erp, J. B. F., & Brouwer, A.-M. (2023) · Sensors · doi:10.3390/s23063006 · Cited by 18
“Suspicious samples in the data were removed based on two criteria: (1) samples higher than 200 bpm or lower than 30 bpm because we consider such values unrealistic in the current setting and (2) samples more than 25% different from the value 1 s before; such changes in HR are considered unrealistic [32].”
Method
Metadata
- Authors
- Cheung, M. N.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1981-05
- Volume
- 18
- Issue
- 3
- Pages
- 341-346
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2059724372
- Cited by
- 75
- References
- 0
- FWCI
- 0.69
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.