Correction of EOG Artifacts in Event‐Related Potentials of the EEG: Aspects of Reliability and Validity
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Correction of EOG artifacts using a regression approach is evaluated in terms of reliability and validity. Transmission rates are estimated for eight EEG channels in 67 subjects. The trimmed group means of these rates are shown to provide reliable measures. Eye artifact correction based on these group means is superior to the conventional rejection in terms of reducing correlation between EOG and EEG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The 1972 Wald Lecture Robust Statistics: A Review
Huber, P. J. (1972) · The Annals of Mathematical Statistics · doi:10.1214/aoms/1177692459 · Cited by 649
Event-related potentials in schizophrenics
Roth, W. T., Horvath, T. B., Pfefferbaum, A., & Kopell, B. S. (1980) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(80)90299-0 · Cited by 214
Eye movement artifact in the CNV
Hillyard, S. A., & Galambos, R. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90185-9 · Cited by 211
Weerts, T. C., & Lang, P. J. (1973) · Biological Psychology · doi:10.1016/0301-0511(73)90010-0 · Cited by 199
McCallum, W. C., & Grey Walter, W. (1968) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(68)90172-7 · Cited by 190
Long‐Latency Evoked Potentials and Reaction Time
Roth, W. T., Ford, J. M., & Kopell, B. S. (1978) · Psychophysiology · doi:10.1111/j.1469-8986.1978.tb01328.x · Cited by 147
A spectral method for removing eye movement artifacts from the EEG
Whitton, J. L., Lue, F. A., & Moldofsky, H. (1978) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(78)90208-0 · Cited by 110
Differential Contributions of Blinks and Vertical Eye Movements as Artifacts in EEG Recording
Corby, J. C., & Kopell, B. S. (1972) · Psychophysiology · doi:10.1111/j.1469-8986.1972.tb00776.x · Cited by 105
A simple on-line technique for removing eye movement artifacts from the EEG
Girton, D. G., & Kamiya, J. (1973) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(73)90052-7 · Cited by 97
Distribution of eye movement and eyeblink potentials over the scalp.
Overton, D. A., & Shagass, C. (1969) · PubMed · Cited by 70
Methodological Issues in CNV Research
Hillyard, S. A. (1974) · Elsevier eBooks · doi:10.1016/b978-0-12-689402-8.50015-8 · Cited by 29
Cited by
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055
A Solution for Reliable and Valid Reduction of Ocular Artifacts, Applied to the P300 ERP
Semlitsch, H. V., Anderer, P., Schuster, P., & Presslich, O. (1986) · Psychophysiology · doi:10.1111/j.1469-8986.1986.tb00696.x · Cited by 2,020
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
ERP components in Go/Nogo tasks and their relation to inhibition
Falkenstein, M., Hoormann, J., & Hohnsbein, J. (1999) · Acta Psychologica · doi:10.1016/s0001-6918(99)00008-6 · Cited by 1,102
Metadata
- Authors
- Verleger, R., Gasser, T., & Möcks, J.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1982-07
- Volume
- 19
- Issue
- 4
- Pages
- 472-480
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2064289481
- Cited by
- 194
- References
- 11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.