Removal of the Ocular Artifact from the EEG: A Comparison of Time and Frequency Domain Methods with Simulated and Real Data
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Frequency‐dependent transfer from EOG to EEG may be insufficiently accounted for by simple time domain regression methods (Gasser, Sroka, & Möcks, 1986; Woestenburg, Verbaten, & Slangen, 1983). In contrast, a multiple‐lag time domain regression analysis, using lagged regression of EEG on EOG, must theoretically account for both frequency dependence and independence. Two data sets were constructed, in which the transfer from EOG to EEG was either frequency‐independent (constant gain) or frequency‐dependent. Subsequently, three different correction methods were applied: 1) a simple regression analysis in the time domain; 2) a multiple‐lag regression analysis in the time domain; and 3) a regression analysis in the frequency domain. The major results were that, for data set 1, the three methods constructed the original EEG equally well. With data set 2, reconstruction of the original EEG was achieved reasonably well with the frequency domain method and the time domain multiple‐lag method, but not with simple time domain regression. These three correction procedures were also applied to real data, consisting of concomitantly recorded EEG and high‐variance EOG series. No appreciable differences in outcome of the three methods were observed, and estimated transfer parameters suggested that these data were marked by weak frequency dependence only, which can be accounted for by simple time domain regression (and also by the other two methods).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for off-line removal of ocular artifact
Gratton, G., Coles, M. G. H., & Donchin, E. (1983) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(83)90135-9 · Cited by 5,055
Cited by
Removing electroencephalographic artifacts by blind source separation
Jung, T., Makeig, S., Humphries, C., Lee, T.-W., McKeown, M. J., Iragui, V. J., & Sejnowski, T. J. (2000) · Psychophysiology · doi:10.1017/s0048577200980259 · Cited by 3,334
Jung, T.-P., Makeig, S., Westerfield, M., Townsend, J., Courchesne, E., & Sejnowski, T. J. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00386-2 · Cited by 1,322
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
Removal of ocular artifact from the EEG: a review
Croft, R. J., & Barry, R. J. (2000) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/s0987-7053(00)00055-1 · Cited by 756
Removal of ocular artifacts from electro-encephalogram by adaptive filtering
He, P., Wilson, G., & Russell, C. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344717 · Cited by 364
Metadata
- Authors
- Kenemans, J. L., Molenaar, P. C. M., Verbaten, M. N., & Slangen, J. L.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1991-01
- Volume
- 28
- Issue
- 1
- Pages
- 114-121
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2063013586
- Cited by
- 149
- References
- 1
- FWCI
- 0.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Removal of the Ocular Artifact from the EEG: A Comparison of Time and Frequency Domain Methods with Simulated and Real Data. https://app.cochat.ai/papers/10.1111/j.1469-8986.1991.tb03397.x
- The paper
- Kenemans, J. L., Molenaar, P. C. M., Verbaten, M. N., & Slangen, J. L. (1991). Removal of the Ocular Artifact from the EEG: A Comparison of Time and Frequency Domain Methods with Simulated and Real Data. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1991.tb03397.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.