Guidelines for Reducing the Risk of Disease Transmission in the Psychophysiology Laboratory
Open accessThe DOI matches its Crossref record.
Abstract
The acquired immunodeficiency syndrome (AIDS) pandemic has highlighted the need for safeguards against the inadvertent transmission of infectious disease in the psychophysiology laboratory. These Guidelines identify factors contributing to the risk of bloodborne disease transmission to subjects or technicians, and recommend procedures to minimize such risk, given current knowledge and techniques. The lowest risk is associated with the application of devices, such as surface electrodes, to non‐abraded, intact skin. Such devices should be clean, but do not require disinfection. The potential risk of infection is higher when surface electrodes are applied to non‐intact skin. Abrasion, or other breaks in the skin, can allow seepage of blood products carrying such pathogens as hepatitis B virus and the human immunodeficiency virus that causes AIDS. Thus electrodes require high‐level disinfection before reuse on non‐intact skin. In addition, technicians should wear gloves during skin preparation and should abrade the skin no more than necessary, using only sterile, preferably non‐sharp materials. The highest risk is that associated with items that enter sterile tissue, such as subdermal electrodes and the needles and lancets sometimes used in skin preparation. Such items must be sterile at the time of use and must be handled with extreme caution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Picton, T. W., Bentin, S., Berg, P., Donchin, E., Hillyard, S. A., Johnson, R., Miller, G. A., Ritter, W., Ruchkin, D. S., Rugg, M. D., et al. (2000) · Psychophysiology · doi:10.1111/1469-8986.3720127 · Cited by 2,157
Self-citationPublication recommendations for electrodermal measurements
Society for Psychophysiological Research Ad Hoc Committee on Electrodermal Measures (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01384.x · Cited by 1,288
Committee report: Guidelines for human startle eyeblink electromyographic studies
Blumenthal, T. D., Cuthbert, B. N., Filion, D. L., Hackley, S., Lipp, O. V., & Van Boxtel, A. (2005) · Psychophysiology · doi:10.1111/j.1469-8986.2005.00271.x · Cited by 1,169
“Reusable electrodes should be cleaned thoroughly and disinfected before they are used with a different participant (see Putnam et al., 1992), avoiding removal of any portion of the AgCl layer.”
BackgroundScalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005
PIVIK, R. T., BROUGHTON, R. J., COPPOLA, R., DAVIDSON, R. J., FOX, N., & NUWER, M. R. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb02081.x · Cited by 676
Metadata
- Authors
- SPR Ad Hoc Committee on the Prevention of Disease Transmission, Putnam, L. E., Johnson, R., & Roth, W. T.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1992-03
- Volume
- 29
- Issue
- 2
- Pages
- 127-141
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2032706333
- Cited by
- 39
- References
- 0
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Guidelines for Reducing the Risk of Disease Transmission in the Psychophysiology Laboratory. https://app.cochat.ai/papers/10.1111/j.1469-8986.1992.tb01676.x
- The paper
- SPR Ad Hoc Committee on the Prevention of Disease Transmission, Putnam, L. E., Johnson, R., & Roth, W. T. (1992). Guidelines for Reducing the Risk of Disease Transmission in the Psychophysiology Laboratory. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1992.tb01676.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.