A Comparison between Two Methods for Assessing Heartbeat Perception
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this study two methods assessing heartbeat perception ability were compared. Subjects (N = 64) completed Schandry's (1981) mental tracking task and Störmer's (1988) heartbeat discrimination procedure (based on Whitehead, Drescher, Heiman, & Blackwell, 1977). In addition, subjects were tested on their ability to estimate the duration of time intervals. A high degree of correspondence was found between the two heartbeat perception tasks for the extreme groups of very good and very poor perceivers, but a low degree of correspondence emerged for the middle range of performance (overall r= .59, p<.001). Time estimation did not correlate significantly with either heartbeat detection procedure. Blood pressure measurements taken after the Schandry task and between Störmer test blocks showed that blood pressure amplitude was elevated among good perceivers on both heartbeat detection tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart beat perception and emotional experience
Schandry, R. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb02486.x · Cited by 1,335
Cited by
Knowing your own heart: Distinguishing interoceptive accuracy from interoceptive awareness
Garfinkel, S. N., Seth, A. K., Barrett, A. B., Suzuki, K., & Critchley, H. D. (2015) · Biological Psychology · doi:10.1016/j.biopsycho.2014.11.004 · Cited by 1,624
Tsakiris, M., Jiménez, A. T., & Costantini, M. (2011) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2010.2547 · Cited by 528
Discrepancies between dimensions of interoception in autism: implications for emotion and anxiety
Garfinkel, S. N., Tiley, C., O'Keeffe, S., Harrison, N. A., Seth, A. K., & Critchley, H. D. (2016) · Biological Psychology · doi:10.1016/j.biopsycho.2015.12.003 · Cited by 512
“…research demonstrates a relationship between objective performance on these two heartbeat tests (e.g. Garfinkel, et al., 2015; Hart, et al., 2013; Knoll & Hodapp, 1992), however this relationship is not always observed, especially in smaller samples (e.g. Phillips, Jones, Rieger, & Snell, 1999;…”
BackgroundHerbert, B. M., Herbert, C., & Pollatos, O. (2011) · Journal of Personality · doi:10.1111/j.1467-6494.2011.00717.x · Cited by 437
Towards a psychophysics of interoceptive processes: the measurement of heartbeat detection
Brener, J., & Ring, C. (2016) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2016.0015 · Cited by 307
Metadata
- Authors
- Knoll, J. F., & Hodapp, V.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1992-03
- Volume
- 29
- Issue
- 2
- Pages
- 218-222
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2127679681
- Cited by
- 106
- References
- 1
- FWCI
- 0.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Comparison between Two Methods for Assessing Heartbeat Perception. https://app.cochat.ai/papers/10.1111/j.1469-8986.1992.tb01689.x
- The paper
- Knoll, J. F., & Hodapp, V. (1992). A Comparison between Two Methods for Assessing Heartbeat Perception. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1992.tb01689.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.