Mismatch Negativity in Event‐Related Potentials to Auditory Stimuli as a Function of Varying Interstimulus Interval
The DOI matches its Crossref record.
Abstract
The mismatch negativity, isolated as a component of the event‐related brain potential elicited by deviant auditory stimuli, was suggested by Näätänen (1984) as an indirect measure of the inferred neuronal representation of standard stimuli. The purpose of the present study was to determine the duration of the neuronal representation by varying the interstimulus intervals of 1, 6, and 10 seconds within experimental blocks. Mismatch negativities were found to be elicited by deviant stimuli (1500‐Hz tones, sequential probability 10%) following standard stimuli (1000‐Hz tones) with interstimulus intervals of 1, 6, and 10 s as well. The results suggest a duration of neuronal representation of at least 10 s. The within‐block variation of interstimulus interval, the rather low temporal probability of deviants, and their large frequency deviance might explain the present results contradicting earlier findings that suggested a shorter duration of that neuronal representation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The mismatch negativity (MMN) in basic research of central auditory processing: A review
Näätänen, R., Paavilainen, P., Rinne, T., & Alho, K. (2007) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.04.026 · Cited by 2,644
“In young, healthy subjects, these traces can last for about 5–10 s, judging from the ISIs that still permit MMN elicitation (Bö ttcher-Gandor and Ullsperger, 1992, Näätänen et al., 1987a; Mäntysalo and Näätänen, 1987; Sams et al., 1993; see also Ritter et al., 2002), but the trace MMN to intensity…”
The mismatch negativity: a review of underlying mechanisms
Garrido, M. I., Kilner, J. M., Stephan, K. E., & Friston, K. J. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.11.029 · Cited by 1,441
“last at least 10 s in normal subjects (Böttcher-Gandor and Ullperger, 1992).”
BackgroundMultiple Time Scales of Adaptation in Auditory Cortex Neurons
Ulanovsky, N., Las, L., Farkas, D., & Nelken, I. (2004) · The Journal of Neuroscience · doi:10.1523/jneurosci.1905-04.2004 · Cited by 708
Mismatch Negativity: Different Water in the Same River
Picton, T. W., Alain, C., Otten, L., Ritter, W., & Achim, A. (2000) · Audiology and Neurotology · doi:10.1159/000013875 · Cited by 578
Interpreting the Mismatch Negativity
Winkler, I. (2007) · Journal of Psychophysiology · doi:10.1027/0269-8803.21.34.147 · Cited by 568
Metadata
- Authors
- Bottcher‐Gandor, C., & Ullsperger, P.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1992-09
- Volume
- 29
- Issue
- 5
- Pages
- 546-550
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W1975087891
- Cited by
- 142
- References
- 0
- FWCI
- 1.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mismatch Negativity in Event‐Related Potentials to Auditory Stimuli as a Function of Varying Interstimulus Interval. https://app.cochat.ai/papers/10.1111/j.1469-8986.1992.tb02028.x
- The paper
- Bottcher‐Gandor, C., & Ullsperger, P. (1992). Mismatch Negativity in Event‐Related Potentials to Auditory Stimuli as a Function of Varying Interstimulus Interval. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1992.tb02028.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.