Comparison of Impedance Cardiographic Measurements using Band and Spot Electrodes
The DOI matches its Crossref record.
Abstract
The comprehensive assessment of cardiac function using impedance cardiography has led to increasingly widespread use of the technique in psychophysiology. Disposable adhesive band electrodes have been the most widely used electrode type, but spot electrode configurations present attractive alternatives in terms of convenience and subject comfort. The present study was designed to evaluate whether one such spot electrode configuration yielded the same information as the more standard band electrodes for cardiac output and systolic time interval measurement. Male and female healthy adult subjects (N=20) were tested. Comparisons between spot and band electrodes were made for the absolute magnitude of cardiac output and systolic time intervals, as well as for responses to the highly reproducible effects of bicycle exercise. Consistent with previous findings, systolic time interval measurements were unaffected by electrode type. However, for cardiac output measurements, differences between spot and band electrode measurements were found. Under resting conditions, the absolute magnitudes of cardiac output values measured using spot electrodes were smaller than for band electrodes. Subtle, yet significant differences were also found for cardiac output responses to exercise, with spot electrodes indicating greater increases in cardiac output than band electrodes. At the same time, anticipated gender differences found for cardiac output at rest and in response to exercise were unaffected by electrode type. Overall, these findings suggest that when comparing the results of studies that have utilized different impedance electrode types, it would be prudent to remain alert to the possibility of confounding influences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardiovascular, electrodermal, and respiratory response patterns to fear‐ and sadness‐inducing films
Kreibig, S. D., Wilhelm, F. H., Roth, W. T., & Gross, J. J. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2007.00550.x · Cited by 495
BERNTSON, G. G., CACIOPPO, J. T., BINKLEY, P. F., UCHINO, B. N., QUIGLEY, K. S., & FIELDSTONE, A. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb02352.x · Cited by 443
CACIOPPO, J. T., BERNTSON, G. G., BINKLEY, P. F., QUIGLEY, K. S., UCHINO, B. N., & FIELDSTONE, A. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb02351.x · Cited by 389
A synergistic mindsets intervention protects adolescents from stress
Yeager, D. S., Bryan, C. J., Gross, J. J., Murray, J. S., Krettek Cobb, D., H. F. Santos, P., Gravelding, H., Johnson, M., & Jamieson, J. P. (2022) · Nature · doi:10.1038/s41586-022-04907-7 · Cited by 225
CACIOPPO, J. T., UCHINO, B. N., & BERNTSON, G. G. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb02449.x · Cited by 223
Metadata
- Authors
- Sherwood, A., Royal, S. A., Hutcheson, J. S., & Turner, J. R.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1992-11
- Volume
- 29
- Issue
- 6
- Pages
- 734-741
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2064415598
- Cited by
- 63
- References
- 0
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of Impedance Cardiographic Measurements using Band and Spot Electrodes. https://app.cochat.ai/papers/10.1111/j.1469-8986.1992.tb02051.x
- The paper
- Sherwood, A., Royal, S. A., Hutcheson, J. S., & Turner, J. R. (1992). Comparison of Impedance Cardiographic Measurements using Band and Spot Electrodes. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1992.tb02051.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.