Assessment of posture and motion by multichannel piezoresistive accelerometer recordings
The DOI matches its Crossref record.
Abstract
Modern assessment of posture and motion involves the use of wide bandwidth piezoresistive accelerometers. The direct current (DC) component allows for assessment of slow motion and change in position referring to the gravitational axis; the alternating current (AC) component, calibrated in g, represents acceleration along the sensitive axis of the device. A method study was designed to evaluate the division in DC and AC components, reliabilities, discrimination between conditions, and detection of types of physical activities. Recordings were made in 26 student participants for eight conditions: sitting, standing, lying supine, sitting and typing on a PC keyboard, walking, climbing stairs, walking downstairs, and cycling. This procedure was repeated in reversed order. A classification of physical activities according to the eight conditions (first trial) and based on four parameters, that is DC components trunk, thigh, and lower leg and AC component trunk, was correct in almost 100% of patterns, when applied to the second trial.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Karantonis, D. M., Narayanan, M. R., Mathie, M., Lovell, N. H., & Celler, B. G. (2006) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2005.856864 · Cited by 1,236
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Activity identification using body-mounted sensors—a review of classification techniques
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., Howard, D., Meijer, K., & Crompton, R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/4/r01 · Cited by 600
LI, G., & BUCKLE, P. (1999) · Ergonomics · doi:10.1080/001401399185388 · Cited by 556
Preece, S. J., Goulermas, J. Y., Kenney, L. P. J., & Howard, D. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2006190 · Cited by 551
“[16] used mean DC mean AC in a hierarchical classification to differentiate between a range of static postures and movements.”
BackgroundMethod
Metadata
- Authors
- FAHRENBERG, J., FOERSTER, F., SMEJA, M., & MÜLLER, W.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 1997-09
- Volume
- 34
- Issue
- 5
- Pages
- 607-612
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W1997778582
- Cited by
- 141
- References
- 0
- FWCI
- 6.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of posture and motion by multichannel piezoresistive accelerometer recordings. https://app.cochat.ai/papers/10.1111/j.1469-8986.1997.tb01747.x
- The paper
- FAHRENBERG, J., FOERSTER, F., SMEJA, M., & MÜLLER, W. (1997). Assessment of posture and motion by multichannel piezoresistive accelerometer recordings. Psychophysiology. https://doi.org/10.1111/j.1469-8986.1997.tb01747.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.