Where to Q in PEP
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The onset of ventricular depolarization defines the start of the preejection period (PEP), which is commonly used as an index of myocardial contractility and sympathetic control of the heart. Although the fiducial point for this onset has traditionally been the onset of the Q wave of the electrocardiogram, other measurement points have also been used in the literature, including the peak of the Q wave (i.e., the onset of the R wave). Conceptual, physiological, and empirical considerations addressing the reliability and validity of these alternative metrics support the application of the Q‐wave peak/R‐wave onset as the fiducial point for PEP measures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cardiac Electrophysiology: From Cell to Bedside
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-12-1069_5 · Cited by 2,385
Methodological Guidelines for Impedance Cardiography
Sherwood(Chair), A., Allen, M. T., Fahrenberg, J., Kelsey, R. M., Lovallo, W. R., & van Doornen, L. J. P. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb02171.x · Cited by 1,169 · cited 3×
“The second system was a Minnesota model 304B Impedance Cardiograph, with standard tetrapolar circumferential band electrodes ( Sherwood et al., 1990 ) and internal EKG derivation.”
BackgroundMethodInfluentialBERNTSON, G. G., CACIOPPO, J. T., BINKLEY, P. F., UCHINO, B. N., QUIGLEY, K. S., & FIELDSTONE, A. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb02352.x · Cited by 443 · cited 3×
“The interscorer differences observed for Qonset were not trivial, but approximate the magnitude of experimental effects of stressors (e.g., on PEP, see Berntson et al., 1994 ).”
BackgroundMethodSelf-citationHemodynamics of Blood Pressure Responses During Active and Passive Coping
Sherwood, A., Dolan, C. A., & Light, K. C. (1990) · Psychophysiology · doi:10.1111/j.1469-8986.1990.tb03189.x · Cited by 414
CACIOPPO, J. T., BERNTSON, G. G., BINKLEY, P. F., QUIGLEY, K. S., UCHINO, B. N., & FIELDSTONE, A. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb02351.x · Cited by 389
Self-citationCardiovascular Indices of Peripheral and Central Sympathetic Activation
Schächinger, H., Weinbacher, M., Kiss, A., Ritz, R., & Langewitz, W. (2001) · Psychosomatic Medicine · doi:10.1097/00006842-200109000-00012 · Cited by 176 · cited 1×
“PEP reflects myocardial contractility and has been validated, with caveats, as an index of sympathetic cardiac control (Berntson et al., 1994; Schachinger, Weinbacher, Kiss, Ritz, & Langewitz, 2001 ).”
MethodKelsey, R. M., Reiff, S., Wiens, S., Schneider, T. R., Mezzacappa, E. S., & Guethlein, W. (1998) · Psychophysiology · doi:10.1017/s0048577298001310 · Cited by 64 · cited 1×
“Some studies employ the peak of the Q wave (onset of the R wave) as the fiducial point ( Kelsey et al., 1998 ), whereas the Society for Psychophysiological Research committee report on impedance cardiography recommends the onset of the Q wave (Qonset), although it acknowledges that the onset of the R wave may be neces…”
MethodIntra- and Interobserver Variations in the Measurement of Systolic Time Intervals
Ishikawa, K., Ishikawa, M., Morihara, H., Yanagtsawa, A., Muramatsu, J., Sawayama, T., & Maeda, K. (1982) · CHEST Journal · doi:10.1378/chest.81.3.341 · Cited by 5 · cited 1×
“There has been little systematic examination of measurement issues associated with the selection of the fiducial point for ventricular activation, although sizeable interscorer measurement errors (3–6 ms) of Qonset have been documented, even among trained cardiologists (Murray & McLaughlin, 1995; Ishikawa et al., 1982…”
Background
Cited by
Karalunas, S. L., Fair, D., Musser, E. D., Aykes, K., Iyer, S. P., & Nigg, J. T. (2014) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2014.763 · Cited by 340
RetractedTask difficulty effects on cardiac activity
Richter, M., Friedrich, A., & Gendolla, G. H. E. (2008) · Psychophysiology · doi:10.1111/j.1469-8986.2008.00688.x · Cited by 283
Feeling good: Autonomic nervous system responding in five positive emotions.
Shiota, M. N., Neufeld, S. L., Yeung, W. H., Moser, S. E., & Perea, E. F. (2011) · Emotion · doi:10.1037/a0024278 · Cited by 261
Lozano, D. L., Norman, G., Knox, D., Wood, B. L., Miller, B. D., Emery, C. F., & Berntson, G. G. (2007) · Psychophysiology · doi:10.1111/j.1469-8986.2006.00468.x · Cited by 241
Self-citationMusser, E. D., Backs, R. W., Schmitt, C. F., Ablow, J. C., Measelle, J. R., & Nigg, J. T. (2011) · Journal of Abnormal Child Psychology · doi:10.1007/s10802-011-9499-1 · Cited by 179
“PEP was indexed as the time interval in milliseconds from the onset of the Q-wave to the B point of the dZ/dt wave, using the method outlined by (Berntson et al. 2004).”
Method
Metadata
- Authors
- Berntson, G. G., Lozano, D. L., Chen, Y., & Cacioppo, J. T.
- Venue
- Psychophysiology
- Publisher
- Wiley
- Published
- 2004-01-09
- Volume
- 41
- Issue
- 2
- Pages
- 333-337
- ISSN
- 0048-5772 (ISSN-L)
- 1469-8986
- OpenAlex
- W2072486834
- Cited by
- 206
- References
- 8
- FWCI
- 1.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.