Fetal crown‐rump length measurement by ultrasound in normal pregnancy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary. Fetal crown‐rump length (CRL) was determined by ultrasound in 105 healthy pregnant women. Each fetus was measured two to four times between the 7th and 14th week, giving a total of 300 observations. The descriptive curve of CRL as a function of age was very similar to those published by others. The longitudinally collected observations showed that CRL in female fetuses was significantly smaller compared with that in male fetuses (P<0·01). There was no demonstrable effect of maternal age, height or parity on fetal CRL. Measurement of CRL enables assessment of gestational age to within ±4–6 days (95% confidence interval), with greatest precision at CRL measurements of 31–40 mm. The discrepancy between ultrasound age as estimated from a CRL measurement and menstrual age may be a variable of prognostic significance in threatened abortion and maternal diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robinson, H. P. (1973) · BMJ · doi:10.1136/bmj.4.5883.28 · Cited by 392
Cited by
Endocrine Control of Body Composition in Infancy, Childhood, and Puberty
Veldhuis, J. D., Roemmich, J. N., Richmond, E. J., Rogol, A. D., Lovejoy, J. C., Sheffield-Moore, M., Mauras, N., & Bowers, C. Y. (2005) · Endocrine Reviews · doi:10.1210/er.2003-0038 · Cited by 452
“forthee....towhom% nosoundisdissonantwhichtellsoflife”% —coleridge
McNay, M., & Fleming, J. E. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00129-x · Cited by 425
Developmental Stages in Human Embryos: Revised and New Measurements
O'Rahilly, R., & Müller, F. (2010) · Cells Tissues Organs · doi:10.1159/000289817 · Cited by 407
Early growth delay in diabetic pregnancy: relation to psychomotor development at age 4
Petersen, M. B., Pedersen, S. A., Greisen, G., Pedersen, J. F., & Molsted-Pedersen, L. (1988) · BMJ · doi:10.1136/bmj.296.6622.598 · Cited by 354
Self-citationUpdated and revised nomenclature for description of early pregnancy events
Farquharson, R. G., Jauniaux, E., & Exalto, N. (2005) · Human Reproduction · doi:10.1093/humrep/dei167 · Cited by 226
“As early ultrasound measurements of the fetus (crown–rump length, CRL) are reproducible (Pedersen, 1982) and more accurate than the use of the LMP, there is a need in publications to define GA based on LMP and/or ultrasound measurements.”
Method
Metadata
- Authors
- PEDERSEN, J. F.
- Venue
- BJOG: An International Journal of Obstetrics & Gynaecology
- Publisher
- Wiley
- Published
- 1982-11
- Volume
- 89
- Issue
- 11
- Pages
- 926-930
- ISSN
- 0306-5456 (ISSN-L)
- 1470-0328
- 1471-0528
- OpenAlex
- W2039504224
- Cited by
- 79
- References
- 1
- FWCI
- 4.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fetal crown‐rump length measurement by ultrasound in normal pregnancy. https://app.cochat.ai/papers/10.1111/j.1471-0528.1982.tb05059.x
- The paper
- PEDERSEN, J. F. (1982). Fetal crown‐rump length measurement by ultrasound in normal pregnancy. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.1982.tb05059.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.