Screening for congenital heart disease prenatally. Results of a 2½‐year study in the South East Thames Region
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objective To assess the efficacy of four chamber view examination, during routine obstetric scanning, in the prenatal detection of fetuses with congenital heart disease. Design Prospective observational study. Setting Ten obstetric ultrasound units in the South East Thames Region. Subjects All pregnant women attending for routine obstetric ultrasound examination. Intervention Ultrasonographers performing routine ultrasound examinations were taught to obtain, and correctly interpret, the four chamber view of the fetal heart. When this view could not be achieved adequately, an attempt was made to identify a reason for failure and, if possible, to arrange a repeat scan. All suspected abnormalities were referred to a specialized unit. Main outcome measures Numbers of true abnormalities detected or overlooked, and the number in whom abnormality was suspected incorrectly. Results Over a 2.5‐year period, 69% of the known number of cardiac lesions associated with an abnormality of the four chamber view were detected prenatally during the routine obstetric scan, 10% were identified as a result of referal for other high‐risk factors and 21% were overlooked. The overall positive predictive value in the 10 obstetric units was 36%. Conclusions Prenatal screening for some forms of major congenital heart disease is possible by including examination of the four chamber view of the fetal heart in routine obstetric scans. However, there are important limiting factors that will influence the success of abnormality detection and must be taken into account if screening is to be effective nationwide.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Saari-Kemppainen, A., Karjalainen, O., Ylostalo, P., & Heinonen, O. P. (1990) · The Lancet · doi:10.1016/0140-6736(90)91941-3 · Cited by 359
Kleinman, C. S., Hobbins, J. C., Jaffe, C. C., Lynch, D. C., & Talner, N. S. (1980) · Pediatrics · doi:10.1542/peds.65.6.1059 · Cited by 283
Congenital Heart Disease: Incidence and Inheritance
Hoffman, J. I. E. (1990) · Pediatric Clinics of North America · doi:10.1016/s0031-3955(16)36830-4 · Cited by 278
Prenatal screening for congenital heart disease.
Allan, L. D., Crawford, D. C., Chita, S. K., & Tynan, M. J. (1986) · BMJ · doi:10.1136/bmj.292.6537.1717 · Cited by 211
Self-citationSpectrum of congenital heart disease detected echocardiographically in prenatal life.
Allan, L. D., Crawford, D. C., Anderson, R. H., & Tynan, M. J. (1985) · Heart · doi:10.1136/hrt.54.5.523 · Cited by 131
Self-citationThe accuracy of fetal echocardiography in the diagnosis of congenital heart disease
Allan, L. D., Chita, S. K., Sharland, G. K., Fagg, N. L. K., Anderson, R. H., & Crawford, D. C. (1989) · International Journal of Cardiology · doi:10.1016/0167-5273(89)90218-0 · Cited by 77
Self-citation
Cited by
ISUOG Practice Guidelines (updated): sonographic screening examination of the fetal heart
Carvalho, J., Allan, L., Chaoui, R., Copel, J., DeVore, G., Hecher, K., Lee, W., Munoz, H., Paladini, D., Tutschek, B., et al. (2013) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.12403 · Cited by 681
Self-citationProspective diagnosis of 1,006 consecutive cases of congenital heart disease in the fetus
Allan, L. D., Sharland, G. K., Milburn, A., Lockhart, S. M., Groves, A. M. M., Anderson, R. H., Cook, A. C., & Nuala, L. K. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90391-3 · Cited by 491
Self-citationImproving the effectiveness of routine prenatal screening for major congenital heart defects
Carvalho, J. S., Mavrides, E., Shinebourne, E. A., Campbell, S., & Thilaganathan, B. (2002) · Heart · doi:10.1136/heart.88.4.387 · Cited by 362
Bull, C. (1999) · The Lancet · doi:10.1016/s0140-6736(99)01167-8 · Cited by 356
Tegnander, E., Williams, W., Johansen, O. J., Blaas, H. ‐. K., & Eik‐Nes, S. H. (2006) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.2710 · Cited by 308
Metadata
- Authors
- SHARLAND, G. K., & ALLAN, L. D.
- Venue
- BJOG: An International Journal of Obstetrics & Gynaecology
- Publisher
- Wiley
- Published
- 1992-03
- Volume
- 99
- Issue
- 3
- Pages
- 220-225
- ISSN
- 0306-5456 (ISSN-L)
- 1470-0328
- 1471-0528
- OpenAlex
- W2131280680
- Cited by
- 207
- References
- 6
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.