Comparison of host response to polypropylene and non‐cross‐linked porcine small intestine serosal‐derived collagen implants in a rat model
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Objective To compare the host response, architectural integration and tensile strength of polypropylene and porcine small intestine submucosa‐derived implants in a rat model. Design Experimental study. Setting Center for Surgical Technologies, Faculty of Medicine, Katholieke Universiteit Leuven, Belgium. Sample Forty‐eight adult male Wistar rats weighing 220–250 g randomised to receive either implant. Methods Full thickness abdominal wall defects were primarily repaired with polypropylene mesh (Marlex) (MX group) or porcine small intestine submucosa (Surgisis) (SIS group). Animals were sacrificed at 7, 14, 30 and 90 days after implantation. Main outcome measures The presence of herniation, infection and intra‐peritoneal adhesions. Change in thickness and tensile strength of implant. Histopathological and immunohistochemical appearances of inflammatory response and collagen deposition. Results Implants from the SIS group showed a short term increase in thickness in the first 14 days. Formation of adhesions was significantly more intense in the MX group at 30 days, and more extensive in the SIS group at 90 days. Tensile strength increased over time in both groups but was significantly lower in the SIS group than the MX group at 30 days. Implants in the MX group showed a more pronounced inflammatory response and more pronounced new vessel formation than the SIS group. Collagen formation was initially more fibrous and better organised in the MX group but became greater in the SIS group at 90 days. Conclusions Biologically derived implant material induced a less pronounced inflammatory response and differences in collagen deposition. At 30 days tensile strength was weaker in the biological implant group but was equivalent by 90 days. These differences may have implications for the in vivo performance of the materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Singer, A. J., & Clark, R. A. F. (1999) · New England Journal of Medicine · doi:10.1056/nejm199909023411006 · Cited by 6,106
Epidemiology of surgically managed pelvic organ prolapse and urinary incontinence
OLSEN, A., SMITH, V, BERGSTROM, J., COLLING, J., & CLARK, A. (1997) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(97)00058-6 · Cited by 3,335
Cited by
Extracellular matrix-based biomaterial scaffolds and the host response
Aamodt, J. M., & Grainger, D. W. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.003 · Cited by 509
The open abdomen in trauma and non-trauma patients: WSES guidelines
Coccolini, F., Roberts, D., Ansaloni, L., Ivatury, R., Gamberini, E., Kluger, Y., Moore, E. E., Coimbra, R., Kirkpatrick, A. W., Pereira, B. M., et al. (2018) · World Journal of Emergency Surgery · doi:10.1186/s13017-018-0167-4 · Cited by 354
Functional skeletal muscle formation with a biologic scaffold
Valentin, J. E., Turner, N. J., Gilbert, T. W., & Badylak, S. F. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.06.039 · Cited by 272
The effect of source animal age upon extracellular matrix scaffold properties
Tottey, S., Johnson, S. A., Crapo, P. M., Reing, J. E., Zhang, L., Jiang, H., Medberry, C. J., Reines, B., & Badylak, S. F. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.09.006 · Cited by 138
“Single-layer SIS-ECM samples in this study and multilayer SIS-ECM samples previously reported by other groups had a peak force per unit width within an order of magnitude of each other [35].”
Elastin-like protein matrix reinforced with collagen microfibers for soft tissue repair
Caves, J. M., Cui, W., Wen, J., Kumar, V. A., Haller, C. A., & Chaikof, E. L. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.009 · Cited by 97
“Adhesions were characterized by documenting the visceral tissues involved, and grading tenacity graded on a 0 to III scale (0 = represents no adhesions; I = adhesions that can be easily separated; II = mild adhesions that are more difficult to separate; and III = dense adhesions which can only be surgically divided [2…”
Metadata
- Authors
- Konstantinovic, M. L., Lagae, P., Zheng, F., Verbeken, E. K., De Ridder, D., & Deprest, J. A.
- Venue
- BJOG: An International Journal of Obstetrics & Gynaecology
- Publisher
- Wiley
- Published
- 2005-09-22
- Volume
- 112
- Issue
- 11
- Pages
- 1554-1560
- ISSN
- 0306-5456 (ISSN-L)
- 1470-0328
- 1471-0528
- OpenAlex
- W2101128134
- Cited by
- 114
- References
- 2
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of host response to polypropylene and non‐cross‐linked porcine small intestine serosal‐derived collagen implants in a rat model. https://app.cochat.ai/papers/10.1111/j.1471-0528.2005.00688.x
- The paper
- Konstantinovic, M. L., Lagae, P., Zheng, F., Verbeken, E. K., De Ridder, D., & Deprest, J. A. (2005). Comparison of host response to polypropylene and non‐cross‐linked porcine small intestine serosal‐derived collagen implants in a rat model. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.2005.00688.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.