CoChat

Systematic review of methodology used in ultrasound studies aimed at creating charts of fetal size

Ioannou, C, Talbot, K, Ohuma, E, Sarris, I, Villar, J, Conde‐Agudelo, A, Papageorghiou, AT · 2012 · BJOG: An International Journal of Obstetrics & Gynaecology
Cited by 151

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Please cite this paper as: Ioannou C, Talbot K, Ohuma E, Sarris I, Villar J, Conde‐Agudelo A, Papageorghiou A. Systematic review of methodology used in ultrasound studies aimed at creating charts of fetal size. BJOG 2012;119:1425–1439. Background Reliable ultrasound charts are necessary for the prenatal assessment of fetal size, yet there is a wide variation of methodologies for the creation of such charts. Objective To evaluate the methodological quality of studies of fetal biometry using a set of predefined quality criteria of study design, statistical analysis and reporting methods. Search strategy Electronic searches in MEDLINE, EMBASE and CINAHL, and references of retrieved articles. Selection criteria Observational studies whose primary aim was to create ultrasound size charts for bi‐parietal diameter, head circumference, abdominal circumference and femur length in fetuses from singleton pregnancies. Data collection and analysis Studies were scored against a predefined set of independently agreed methodological criteria and an overall quality score was given to each study. Multiple regression analysis between quality scores and study characteristics was performed. Main results Eighty‐three studies met the inclusion criteria. The highest potential for bias was noted in the following fields: ‘Inclusion/exclusion criteria’, as none of the studies defined a rigorous set of antenatal or fetal conditions which should be excluded from analysis; ‘Ultrasound quality control measures’, as no study demonstrated a comprehensive quality assurance strategy; and ‘Sample size calculation’, which was apparent in six studies only. On multiple regression analysis, there was a positive correlation between quality scores and year of publication: quality has improved with time, yet considerable heterogeneity in study methodology is still observed today. Conclusions There is considerable methodological heterogeneity in studies of fetal biometry. Standardisation of methodologies is necessary in order to make correct interpretations and comparisons between different charts. A checklist of recommended methodologies is proposed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1471-0528.2012.03451.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 151

Metadata

Authors
Ioannou, C., Talbot, K., Ohuma, E., Sarris, I., Villar, J., Conde‐Agudelo, A., & Papageorghiou, A.
Venue
BJOG: An International Journal of Obstetrics & Gynaecology
Publisher
Wiley
Published
2012-08-13
Volume
119
Issue
12
Pages
1425-1439
ISSN
  • 0306-5456 (ISSN-L)
  • 1470-0328
  • 1471-0528
OpenAlex
W2131644368
Cited by
151
References
1
FWCI
2.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Systematic review of methodology used in ultrasound studies aimed at creating charts of fetal size. https://app.cochat.ai/papers/10.1111/j.1471-0528.2012.03451.x
The paper
Ioannou, C., Talbot, K., Ohuma, E., Sarris, I., Villar, J., Conde‐Agudelo, A., & Papageorghiou, A. (2012). Systematic review of methodology used in ultrasound studies aimed at creating charts of fetal size. BJOG: An International Journal of Obstetrics & Gynaecology. https://doi.org/10.1111/j.1471-0528.2012.03451.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.