Ambulatory blood pressure monitoring and cardiovascular function tests in multiple system atrophy
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Summary— Cardiovascular tests (CT) of autonomic function and non‐invasive ambulatory blood pressure (BP) and heart rate (HR) monitoring were performed in 17 patients with multiple system atrophy (MSA) (mean age 61 ± 9 years) and in 12 healthy subjects matched for sex and age. CT showed severe autonomic dysfunction with orthostatic hypotension (OH) in eight patients with MSA (47%) (Group I). The remaining nine out of the 17 patients didn't show BP abnormalities during CT but an impaired HR reflex response was found (Group II). BP monitoring showed a reversed circadian BP rhythm in Group I with higher night‐time than day‐time values, a blunted circadian BP pattern in Group II and a normal day‐night BP reduction in controls. Day‐night HR reduction was poor in Group II and absent in Group I. Post‐prandial hypotension was evaluated after a standard meal. In Group I systolic/diastolic BP fell within 30 minutes after meal (from 135 ± 16/89 ± 13 to 118 ± 17/73 ± 12 mmHg; p < 0.05) and after two hours had not returned to basal levels. In Group II a reduction of only systolic BP was found within 45 minutes after meal and persisted for one hour. OH clinically identifies a subgroup of MSA patients with a more severe BP dysregulation characterized by severe post‐prandial hypotension and reversed circadian BP rhythm. CT and ambulatory BP monitoring are useful tools in identifying early stage of cardiovascular autonomic impairment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The circadian blood pressure pattern in ambulatory normal subjects
Weber, M. A., Drayer, J. I. M., Nakamura, D. K., & Wyle, F. A. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90314-x · Cited by 128
Cited by
Druschky, A., Hilz, M. J., Platsch, G., Radespiel-Tröger, M., Druschky, K., Kuwert, T., & Neundörfer, B. (2000) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(00)00279-3 · Cited by 221
Loss of nocturnal blood pressure fall in various extrapyramidal syndromes
Schmidt, C., Berg, D., Herting, Prieur, S., Junghanns, S., Schweitzer, K., Globas, C., Schöls, L., Reichmann, H., & Ziemssen, T. (2009) · Movement Disorders · doi:10.1002/mds.22767 · Cited by 113
Ageing, the autonomic nervous system and arrhythmia: From brain to heart
Chadda, K. R., Ajijola, O. A., Vaseghi, M., Shivkumar, K., Huang, C. L.-H., & Jeevaratnam, K. (2018) · Ageing Research Reviews · doi:10.1016/j.arr.2018.09.005 · Cited by 77
The potential prognostic role of cardiovascular autonomic failure in α‐synucleinopathies
Fanciulli, A., Strano, S., Colosimo, C., Caltagirone, C., Spalletta, G., & Pontieri, F. E. (2013) · European Journal of Neurology · doi:10.1111/j.1468-1331.2012.03819.x · Cited by 77
Fanciulli, A., Strano, S., Ndayisaba, J. P., Goebel, G., Gioffrè, L., Rizzo, M., Colosimo, C., Caltagirone, C., Poewe, W., Wenning, G. K., et al. (2014) · Journal of Neurology · doi:10.1007/s00415-014-7339-2 · Cited by 67
Metadata
- Authors
- Frongillo, D., Stocchi, F., Buccolini, P., Stecconi, P., Viselli, F., Ruggieri, S., & Cannata, D.
- Venue
- Fundamental & Clinical Pharmacology
- Publisher
- Wiley
- Published
- 1995-03-04
- Volume
- 9
- Issue
- 2
- Pages
- 187-196
- ISSN
- 0767-3981 (ISSN-L)
- 1472-8206
- OpenAlex
- W2165598172
- Cited by
- 17
- References
- 1
- FWCI
- 0.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.