Total body bone mineral in vivo by dual photon absorptiometry. I. Measurement procedures
The DOI matches its Crossref record.
Abstract
Summary. A dual photon scanner using a 1 Ci 153 Gd source, a NaI detector, traditional electronics and a desktop computer, was constructed. Software for the computation of the total body bone mineral (TBBM) was developed. Non‐linear influences such as deadtime due to high count rates, patient scatter and Compton effects were investigated and correction algorithms were introduced in order to obtain exponential attenuation. System precision was measured on a bone‐aluminium standard (CV=2·6%) and system linearity was assessed on aluminium pieces (r=0·999, SEE=3·0%). Short‐term precision in vivo was tested on 15 healthy subjects scanned twice with a 2‐month interval (CV=2·4%). Long‐term reproducibility in vivo was tested on two healthy subjects scanned eight times with 1‐month intervals (CV=1·9% and 3·2%). The influence of patient orientation was investigated on two skeletons. No significant difference was found between anatomical and random orientation. It was concluded that the precision errors were small, therefore making the method applicable not only in cross‐sectional studies but also in longitudinal studies designed to investigate the loss or gain of total bone mass in patients suffering from calcium metabolic disorders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mazess, R., Barden, H., Bisek, J., & Hanson, J. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.6.1106 · Cited by 1,476
Self-citationDual-energy X-ray absorptiometry body composition model: review of physical concepts
Pietrobelli, A., Formica, C., Wang, Z., & Heymsfield, S. B. (1996) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1996.271.6.e941 · Cited by 594
Human Body Composition: Advances in Models and Methods
B. Heymsfield, S., Wang, Z., Baumgartner, R. N., & Ross, R. (1997) · Annual Review of Nutrition · doi:10.1146/annurev.nutr.17.1.527 · Cited by 527
Does Calcium Supplementation Prevent Postmenopausal Bone Loss?
Rus, B., Thomsen, K., & Christiansen, C. (1987) · New England Journal of Medicine · doi:10.1056/nejm198701223160401 · Cited by 523
Self-citationValidation of body composition by dual energy X‐ray absorptiometry (DEXA)
Haarbo, J., Gotfredsen, A., Hassager, C., & Christiansen, C. (1991) · Clinical Physiology · doi:10.1111/j.1475-097x.1991.tb00662.x · Cited by 419
Self-citation
Metadata
- Authors
- Gotfredsen, A., Borg, J., Christiansen, C., & Mazess, R. B.
- Venue
- Clinical Physiology
- Publisher
- Wiley
- Published
- 1984-08
- Volume
- 4
- Issue
- 4
- Pages
- 343-355
- ISSN
- 0144-5979 (ISSN-L)
- 1365-2281
- OpenAlex
- W2112088567
- Cited by
- 83
- References
- 0
- FWCI
- 16.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Total body bone mineral in vivo by dual photon absorptiometry. I. Measurement procedures. https://app.cochat.ai/papers/10.1111/j.1475-097x.1984.tb00809.x
- The paper
- Gotfredsen, A., Borg, J., Christiansen, C., & Mazess, R. B. (1984). Total body bone mineral in vivo by dual photon absorptiometry. I. Measurement procedures. Clinical Physiology. https://doi.org/10.1111/j.1475-097x.1984.tb00809.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.