The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Validation of body composition by dual energy X‐ray absorptiometry (DEXA)
Abstract
Summary. The present study validates the use of dual energy X‐ray absorptiometry (DEXA) for measurement of body composition. The precision error was expressed as the SD (CV%) for fat mass, FAT%, lean tissue mass, and total body bone mineral: 1·1 kg (6·4%), 1·6% (5·7%), 1·4 kg (3·1%), and 0·03 kg (1·2%), respectively. The accuracy study in vitro used (1) mixtures of water and alcohol, (2) mixtures of ox muscle and lard, and (3) dried bones. In the clinically relevant range of values there were only small influences on DEXA measurements of variations in amount and composition of the soft tissue equivalents. The accuracy study in vivo compared the components of body composition measured recently by DEXA and earlier by dual photon absorptiometry, counting of naturally occurring total body 40 K, and body density by underwater weighing in 25 healthy adult subjects. We found agreement between fat percentage (and lean body mass) by DEXA and the three established measurements modalities; mean differences were (‐5·3 to ‐0·4%) and (‐0·7 to 2·5 kg) for fat percentage and lean body mass, respectively. We conclude that DEXA provides a new method of measuring body composition with precision and accuracy errors, which are compatible with the application of DEXA in group research studies and probably also in clinical measurements of the single subject.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lapidus, L., Bengtsson, C., Larsson, B., Pennert, K., Rybo, E., & Sjöström, L. (1984) · BMJ · doi:10.1136/bmj.289.6454.1257 · Cited by 1,660
DENSITOMETRIC ANALYSIS OF BODY COMPOSITION: REVISION OF SOME QUANTITATIVE ASSUMPTIONS*
Brožek, J., Grande, F., Anderson, J. T., & Keys, A. (1963) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1963.tb17079.x · Cited by 1,531
Mazess, R., Barden, H., Bisek, J., & Hanson, J. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.6.1106 · Cited by 1,476
Methods for the assessment of human body composition: traditional and new
Lukaski, H. C. (1987) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/46.4.537 · Cited by 1,152
Evans, D. J., Hoffman, R. G., Kalkhoff, R. K., & Kissebah, A. H. (1984) · Metabolism · doi:10.1016/0026-0495(84)90164-1 · Cited by 390
Performance evaluation of a dual-energy X-ray bone densitometer
Mazess, R., Collick, B., Trempe, J., Barden, H., & Hanson, J. (1989) · Calcified Tissue International · doi:10.1007/bf02556569 · Cited by 352
Heymsfield, S. B., Wang, J., Heshka, S., Kehayias, J. J., & Pierson, R. N. (1989) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/49.6.1283 · Cited by 277
WAHNER, H. W., DUNN, W. L., BROWN, M. L., MORIN, R. L., & RIGGS, B. L. (1988) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(12)65502-5 · Cited by 229
Quantitative Digital Radiography Versus Dual Photon Absorptiometry of the Lumbar Spine*
KELLY, T. L., SLOVIK, D. M., SCHOENFELD, D. A., & NEER, R. M. (1988) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-67-4-839 · Cited by 214
Total body composition by dual-photon (153Gd) absorptiometry
Mazess, R. B., Peppler, W. W., & Gibbons, M. (1984) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/40.4.834 · Cited by 153
Cited by
Carr, A., Samaras, K., Thorisdottir, A., Kaufmann, G. R., Chisholm, D. J., & Cooper, D. A. (1999) · The Lancet · doi:10.1016/s0140-6736(98)08468-2 · Cited by 1,495
Changes in fat-free mass during significant weight loss: a systematic review
Chaston, T. B., Dixon, J. B., & O'Brien, P. E. (2007) · International Journal of Obesity · doi:10.1038/sj.ijo.0803483 · Cited by 493
Association of Body Fat Distribution and Cardiovascular Risk Factors in Children and Adolescents
Daniels, S. R., Morrison, J. A., Sprecher, D. L., Khoury, P., & Kimball, T. R. (1999) · Circulation · doi:10.1161/01.cir.99.4.541 · Cited by 444
Postmenopausal hormone replacement therapy prevents central distribution of body fat after menopause
Haarbo, J., Marslew, U., Gotfredsen, A., & Christiansen, C. (1991) · Metabolism · doi:10.1016/0026-0495(91)90037-w · Cited by 441
Self-citationVisser, M., Fuerst, T., Lang, T., Salamone, L., Harris, T. B., Health, F. T., Absorptiometry, A., & Group, B. C. W. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.4.1513 · Cited by 422
Metadata
- Authors
- Haarbo, J., Gotfredsen, A., Hassager, C., & Christiansen, C.
- Venue
- Clinical Physiology
- Publisher
- Wiley
- Published
- 1991-07
- Volume
- 11
- Issue
- 4
- Pages
- 331-341
- ISSN
- 0144-5979 (ISSN-L)
- 1365-2281
- OpenAlex
- W2031639163
- Cited by
- 419
- References
- 21
- FWCI
- 5.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Validation of body composition by dual energy X‐ray absorptiometry (DEXA). https://app.cochat.ai/papers/10.1111/j.1475-097x.1991.tb00662.x
- The paper
- Haarbo, J., Gotfredsen, A., Hassager, C., & Christiansen, C. (1991). Validation of body composition by dual energy X‐ray absorptiometry (DEXA). Clinical Physiology. https://doi.org/10.1111/j.1475-097x.1991.tb00662.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.