Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 236

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Assessment of the composition of major body regions by dual‐energy X‐ray absorptiometry (DEXA), with special reference to limb muscle mass

Fuller, N. J., Laskey, M. A., Elia, M.·1992·Clinical Physiology

Abstract

Summary Dual‐energy X‐ray absorptiometry (DEXA) has been used to assess and compare the composition of whole body and major body regions in 12 female (weight, 56.9 ± 6–2 kg; BMI, 17.25 kg m‐2) and 16 male (weight, 73.1 ± 9–6 kg; BMI, 20.28 kg m‐2) healthy subjects. Standard deviations (and % coefficients of variation) of the differences between repeated measurements of fat ranged from 0.11 kg (9.0%) for arms to 0.42 kg (30%) for whole body; for arm bone mineral, 0.01 kg (2.0%), and for fat‐free soft tissue of the whole body, 0.42 kg (0.8%). Limb muscle mass was estimated using a new theoretical model of body composition, and the corresponding precision ranged from 015 kg (3.8%) to 0.27 kg (1.5%) for arms and total limb muscle mass, respectively. Proportions of each region consisting of fat were greater in females than in males (range, 20.31% vs. 16.18%), respectively, but the ratio of trunk to leg fat was lower (34:49% vs. 46:38%, respectively). Regional proportions of bone were similar between the sexes (all in the range 2.9–5.6%, for both females and males). Mean total limb muscle masses were 14.2 kg (arms, 2.8 kg; legs, 11.4 kg) for females and 22.2 kg (arms, 4.8 kg; legs, 17.4 kg) for males, which were 33.6% and 36.0% of fat‐free mass, respectively. The correlation coefficients between limb muscle (DEXA) and other indices of muscle mass were: for DEXA vs. total body potassium, 0.90 (SEE 1.1kg muscle mass) to 0.94 (1.6 kg); and for DEXA vs. anthropometry, 0.43 (1.2 kg) to 0.85 (1.3 kg). Those for limb volume (DEXA) vs. anthropometric volume, 0.91 (0.78 1) to 0.94 (1.91 1). It is concluded that DEXA enables the valid and reproducible estimation of fat, fat‐free soft tissue, bone, and limb muscle mass.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1475-097x.1992.tb00831.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 236

Metadata

Authors
Fuller, N. J., Laskey, M. A., & Elia, M.
Venue
Clinical Physiology
Publisher
Wiley
Published
1992-05
Volume
12
Issue
3
Pages
253-266
ISSN
  • 0144-5979 (ISSN-L)
  • 1365-2281
OpenAlex
W2081610069
Cited by
236
References
1
FWCI
3.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of the composition of major body regions by dual‐energy X‐ray absorptiometry (DEXA), with special reference to limb muscle mass. https://app.cochat.ai/papers/10.1111/j.1475-097x.1992.tb00831.x
The paper
Fuller, N. J., Laskey, M. A., & Elia, M. (1992). Assessment of the composition of major body regions by dual‐energy X‐ray absorptiometry (DEXA), with special reference to limb muscle mass. Clinical Physiology. https://doi.org/10.1111/j.1475-097x.1992.tb00831.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.