Cardiac output and blood pressure during active and passive standing
The DOI matches its Crossref record.
Abstract
Summary. The present study compared the haemodynamic pattern of active and passive standing. We used non‐invasive techniques with beat‐to‐beat evaluation of blood pressure, heart rate and stroke volume. Seven healthy subjects, aged 24–41 (mean 30) years were examined. Finger blood pressure was continuously recorded by volume clamp technique (Finapres ®), and simultaneous beat‐to‐beat beat stroke volume was obtained, using an ultrasound Doppler technique, from the product of the valvular area and the aortic flow velocity time integral in the ascending aorta from the suprasternal notch. Measurements were performed at rest, during active standing and following passive tilt (60°). Active standing caused a transient but greater reduction of blood pressure and a higher increase of heart rate than passive tilt during the first 30 s (δ mean blood pressure: ‐39 ± 10 vs. ‐16 ± 7 mmHg, δ heart rate: 35 ± 8 vs. 12 ± 7 beats m‐1 (active standing vs. passive tilt; P < 0.01). There was a significantly larger increase in cardiac output during active standing (37 ± 24 vs. 0 ± 15%, P < 0.01) and a more marked decrease in total peripheral resistance (‐58 ± 11 vs. ‐16 ± 17%, P < 0.01). A precipitous rise in intra‐abdominal pressure (43 ± 22 mmHg) could be observed upon rising only in active standing. This was interpreted as an indication of translocation of blood to the thorax. There was no significant difference in haemodynamic changes during the later stage of standing (1–7 min) between both manoeuvres. These results suggest that active standing causes a marked blood pressure reduction in the initial phase which seems to reflect systemic vasodilatation caused by activation of cardiopulmonary baroreflexes, probably due to a rapid shift of blood from the splanchnic vessels in addition to the shift from muscular vessels associated with abdominal and calf muscle contraction. Moreover, the ultrasound Doppler technique was found to be a more adequate method for rapid beat‐to‐beat evaluation of cardiac output during orthostatic manoeuvres.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Initial orthostatic hypotension: review of a forgotten condition
Wieling, W., Krediet, C. T. P., van Dijk, N., Linzer, M., & Tschakovsky, M. E. (2007) · Clinical Science · doi:10.1042/cs20060091 · Cited by 374
Barbieri, R., Matten, E. C., Alabi, A. A., & Brown, E. N. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00482.2003 · Cited by 307
Norcliffe‐Kaufmann, L., Kaufmann, H., Palma, J., Shibao, C. A., Biaggioni, I., Peltier, A. C., Singer, W., Low, P. A., Goldstein, D. S., Gibbons, C. H., et al. (2018) · Annals of Neurology · doi:10.1002/ana.25170 · Cited by 242
“The HR changes were measured in response to tilt (ie, passive standing) and not in response to active standing, which may be more widely used in the clinical setting, although it should be expected to be similar.(43) A blunted HR response to standing has also been described in patients with OH due to diabetic autonomi…”
BackgroundCheshire, W. P., Freeman, R., Gibbons, C. H., Cortelli, P., Wenning, G. K., Hilz, M. J., Spies, J. M., Lipp, A., Sandroni, P., Wada, N., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2020.11.024 · Cited by 189
van Lieshout, J. J., ten Harkel, A. D. J., & Wieling, W. (2000) · Clinical Autonomic Research · doi:10.1007/bf02291388 · Cited by 144
“Orthostatic circulatory responses before treatment In normal humans, standing up from the supine position causes a decrease of 30% to 40% in SV. The subsequent decrease in CO remains limited by a reflex increase in HR, and mean BP either does not change or increases slightly through reflex vasoconstriction (Fig. 1) […”
Background
Metadata
- Authors
- Tanaka, H., Sjöberg, B. J., & Thulesius, O.
- Venue
- Clinical Physiology
- Publisher
- Wiley
- Published
- 1996-03
- Volume
- 16
- Issue
- 2
- Pages
- 157-170
- ISSN
- 0144-5979 (ISSN-L)
- 1365-2281
- OpenAlex
- W2140503445
- Cited by
- 115
- References
- 0
- FWCI
- 0.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cardiac output and blood pressure during active and passive standing. https://app.cochat.ai/papers/10.1111/j.1475-097x.1996.tb00565.x
- The paper
- Tanaka, H., Sjöberg, B. J., & Thulesius, O. (1996). Cardiac output and blood pressure during active and passive standing. Clinical Physiology. https://doi.org/10.1111/j.1475-097x.1996.tb00565.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.