Reliability of knee extension and flexion measurements using the Con‐Trex isokinetic dynamometer
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Summary: The aim of this study was to evaluate the reliability of isokinetic and isometric assessments of the knee extensor and the flexor muscle function using the Con‐Trex isokinetic dynamometer. Thirty healthy subjects (15 males, 15 females) were tested and retested 7 days later for maximal strength (isokinetic peak torque, work, power and angle of peak torque as well as isometric maximal voluntary contraction torque and rate of torque development) and fatigue (per cent loss and linear slope of torque and work across a series of 20 contractions). For both the knee extensor and the flexor muscle groups, all strength data – except angle of peak torque – demonstrated moderate‐to‐high reliability, with intraclass correlation coefficients (ICC) higher than 0·86. The highest reliability was observed for concentric peak torque of the knee extensor muscles (ICC = 0·99). Test–retest reliability of fatigue variables was moderate for the knee extensor (ICC range 0·84–0·89) and insufficient‐to‐moderate for the knee flexor muscles (ICC range 0·78–0·81). The more reliable index of muscle fatigue was the linear slope of the decline in work output. These findings establish the reliability of isokinetic and isometric measurements using the Con‐Trex machine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779 · cited 2×
“Relative reliability concerns the degree to which individuals maintain their position in a sample with repeated measurements (Atkinson & Nevill, 1998).”
BackgroundVincent, W. J. (1994) · Cited by 1,016
Valovich-mcLeod, T. C., Shultz, S. J., Gansneder, B. M., Perrin, D. H., & Drouin, J. M. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0933-0 · Cited by 839 · cited 2×
“machines has been the focus of a series of manuscripts (Feiring et al., 1990; Bandy & McLaughlin, 1993; Bemben & Johnson, 1993; Brown et al., 1993; Li et al., 1996; Drouin et al., 2004; Lund et al., 2005).”
BackgroundMethodForce-velocity relations and fiber composition in human knee extensor muscles
Thorstensson, A., Grimby, G., & Karlsson, J. (1976) · Journal of Applied Physiology · doi:10.1152/jappl.1976.40.1.12 · Cited by 585 · cited 1×
“For the isometric trials, the knee joint was fixed at an angle of 60 of flexion, which has been demonstrated to be the angle of maximal isometric force generation (Thorstensson et al., 1976).”
MethodPhysiological tests for elite athletes
Gore, C. J. (2000) · Cited by 524
Isokinetic Evaluation of Muscular Performance
Kannus, P. (1994) · International Journal of Sports Medicine · doi:10.1055/s-2007-1021104 · Cited by 444 · cited 1×
“…of contractions – is another feature that can be assessed using isokinetic techniques, usually at a relatively fast concentric velocity over 20–50 consecutive maximal-effort repetitions (Thorstensson & Karlsson, 1976; Kannus et al., 1992; Kannus, 1994; Emery et al., 1999; Pincivero et al., 2001).”
BackgroundIsokinetic exercise and assessment
(1993) · Choice Reviews Online · doi:10.5860/choice.31-1579 · Cited by 366 · cited 2×
“Isokinetic muscle strength is typically measured as peak torque, average work and power (Perrin, 1993; Brown, 2000; Wrigley & Strauss, 2000).”
BackgroundMethodTest-Retest Reliability of the Biodex Isokinetic Dynamometer
Feiring, D. C., Ellenbecker, T. S., & Derscheid, G. L. (1990) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.1990.11.7.298 · Cited by 359 · cited 2×
“machines has been the focus of a series of manuscripts (Feiring et al., 1990; Bandy & McLaughlin, 1993; Bemben & Johnson, 1993; Brown et al., 1993; Li et al., 1996; Drouin et al., 2004; Lund et al., 2005).”
BackgroundMethodFatiguability and Fibre Composition of Human Skeletal Muscle
Thorstensson, A., & Karlsson, J. (1976) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1976.tb10316.x · Cited by 328 · cited 2×
“Peak torque and work losses were then calculated as the per cent difference between postfatigue and prefatigue data (Thorstensson & Karlsson, 1976).”
BackgroundMethodLi, R. C., Wu, Y., Maffulli, N., Chan, K.-M., & Chan, J. L. C. (1996) · British Journal of Sports Medicine · doi:10.1136/bjsm.30.2.156 · Cited by 202 · cited 4×
“machines has been the focus of a series of manuscripts (Feiring et al., 1990; Bandy & McLaughlin, 1993; Bemben & Johnson, 1993; Brown et al., 1993; Li et al., 1996; Drouin et al., 2004; Lund et al., 2005).”
BackgroundMethodInfluentialReliability and Repeatability of Methods for Measuring Muscle in Physiotherapy
Stokes, M. J. (1985) · Physiotherapy Practice · doi:10.3109/09593988509163853 · Cited by 180 · cited 1×
“To interpret the CV values, we used the arbitrary suggestions made by Stokes (1985) with an analytical goal of 15% or below.”
MethodLund, H., Søndergaard, K., Zachariassen, T., Christensen, R., Bülow, P., Henriksen, M., Bartels, E. M., Danneskiold‐Samsøe, B., & Bliddal, H. (2005) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2004.00593.x · Cited by 173 · cited 3×
“machines has been the focus of a series of manuscripts (Feiring et al., 1990; Bandy & McLaughlin, 1993; Bemben & Johnson, 1993; Brown et al., 1993; Li et al., 1996; Drouin et al., 2004; Lund et al., 2005).”
BackgroundMethodIsokinetics in Human Performance
Snyder-Mackler, L. (2000) · Medicine and Science in Sports and Exercise · doi:10.1097/00005768-200012000-00034 · Cited by 146 · cited 3×
“large number of parameters, but we retained only those commonly used in isokinetic studies, namely the peak torque, the average work, the average power and the angle of peak torque (Brown et al., 1992; Perrin, 1993; Brown, 2000; Wrigley & Strauss, 2000).”
BackgroundMethodIsokinetics in Human Performance
Brown, L. R. (2000) · Cited by 137
Reliability of Measurements of Concentric and Eccentric Isokinetic Loading
Tredinnick, T. J., & Duncan, P. W. (1988) · Physical Therapy · doi:10.1093/ptj/68.5.656 · Cited by 136 · cited 2×
“…studies have demonstrated acceptable intra and intersession reliability for various kinds of isokinetic machines, such as the Biodex (Brown et al., 1993; Lund et al., 2005), Cybex (Bandy & McLaughlin, 1993; Li et al., 1996), Kin Com (Tredinnick & Duncan, 1988) and Merac (Capranica et al., 1998).”
BackgroundForce-Velocity Relationship and Stretch-Shortening Cycle Function in Sprint and Endurance Athletes
Harrison, A. J., Keane, S. P., & Coglan, J. (2004) · The Journal of Strength and Conditioning Research · doi:10.1519/00124278-200408000-00014 · Cited by 125
Wilhite, M. R., Cohen, E. R., & Wilhite, S. C. (1992) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1992.15.4.175 · Cited by 117 · cited 1×
“Concentric measurements involved three continuous, reciprocal (maximal) knee extensions and flexions, which were performed at three preset constant angular velocities, in the following order: 60, 120, 180 s)1 (slow to fast) (Wilhite et al., 1992).”
MethodSkeletal muscle collagen content in humans after high-force eccentric contractions
Mackey, A. L., Donnelly, A. E., Turpeenniemi-Hujanen, T., & Roper, H. P. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01174.2003 · Cited by 105 · cited 3×
“Several scientific studies have used this device to assess static (isometric) and dynamic (eccentric and concentric) function of both the knee extensor and the flexor muscles (Cotte & Ferret, 2003; Bardis et al., 2004; Harrison et al., 2004; Mackey et al., 2004; Koller et al., 2006; Kilgallon et al., 2007).”
MethodProgressive resistance training temporarily alters hamstring torque–angle relationship
Kilgallon, M., Donnelly, A., & Shafat, A. (2005) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.2005.00491.x · Cited by 83 · cited 2×
“Several scientific studies have used this device to assess static (isometric) and dynamic (eccentric and concentric) function of both the knee extensor and the flexor muscles (Cotte & Ferret, 2003; Bardis et al., 2004; Harrison et al., 2004; Mackey et al., 2004; Koller et al., 2006; Kilgallon et al., 2007).”
MethodAssessment of the reliability of high-intensity quadriceps femoris muscle fatigue
Pincivero, D. M., GEAR, W. S., & Sterner, R. L. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200102000-00025 · Cited by 73 · cited 3×
“…of contractions – is another feature that can be assessed using isokinetic techniques, usually at a relatively fast concentric velocity over 20–50 consecutive maximal-effort repetitions (Thorstensson & Karlsson, 1976; Kannus et al., 1992; Kannus, 1994; Emery et al., 1999; Pincivero et al., 2001).”
BackgroundMethodResultIntramachine and Intermachine Reliability for Selected Dynamic Muscle Performance Tests
Bandy, W. D., & McLaughlin, S. (1993) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1993.18.5.609 · Cited by 58 · cited 6×
“To our knowledge, there are nowadays three main manufacturers vending isokinetic devices throughout the world: CSMI solutions (Stoughton, MA, USA) for Humac Norm (Cybex), Biodex Medical System (Shirley, NY, USA) for Biodex system 3 and CMV AG for Con-Trex MJ.”
BackgroundMethodInfluentialDecrease in eccentric hamstring strength in runners in the Tirol Speed Marathon
Koller, A., Sumann, G., Schobersberger, W., Hoertnagl, H., & Haid, C. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.028175 · Cited by 30
Comparative study of two isokinetics dynamometers: CYBEX NORM vs CON-TREX MJ
Cotte, T., & Ferret, J. M. (2003) · Isokinetics and Exercise Science · doi:10.3233/ies-2003-0111 · Cited by 29 · cited 2×
“Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer”
MethodBardis, C., Kalamara, E., Loucaides, G., Michaelides, M., & Tsaklis, P. (2004) · Isokinetics and Exercise Science · doi:10.3233/ies-2004-0155 · Cited by 24 · cited 2×
“Several scientific studies have used this device to assess static (isometric) and dynamic (eccentric and concentric) function of both the knee extensor and the flexor muscles (Cotte & Ferret, 2003; Bardis et al., 2004; Harrison et al., 2004; Mackey et al., 2004; Koller et al., 2006; Kilgallon et al., 2007).”
MethodWalter (1998) · doi:10.1002/(sici)1097-0258(19980115)17:1<101::aid-sim727>3.0.co;2-e · cited 2×
“1Neuromuscular Research Laboratory, Schulthess Clinic, Zurich, Switzerland, 2Occupational Physiology Laboratory, National Institute for Research and Security, Nancy, France, and 3Performance Expertise Centre, Faculty of Sport Sciences, University of Burgundy, Dijon, France”
BackgroundMethod
Cited by
Maltais, F., Decramer, M., Casaburi, R., Barreiro, E., Burelle, Y., Debigaré, R., Dekhuijzen, P. N. R., Franssen, F., Gayan-Ramirez, G., Gea, J., et al. (2014) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201402-0373st · Cited by 1,090
Sprint Acceleration Mechanics: The Major Role of Hamstrings in Horizontal Force Production
Morin, J.-B., Gimenez, P., Edouard, P., Arnal, P., Jiménez-Reyes, P., Samozino, P., Brughelli, M., & Mendiguchia, J. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00404 · Cited by 370
Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer
Impellizzeri, F. M., Bizzini, M., Rampinini, E., Cereda, F., & Maffiuletti, N. A. (2008) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2007.00786.x · Cited by 279
Self-citationOpar, D. A., Piatkowski, T., Williams, M. D., & Shield, A. J. (2013) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2013.4837 · Cited by 263
Undheim, M. B., Cosgrave, C., King, E., Strike, S., Marshall, B., Falvey, É., & Franklyn-Miller, A. (2015) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093962 · Cited by 260
Metadata
- Authors
- Maffiuletti, N. A., Bizzini, M., Desbrosses, K., Babault, N., & Munzinger, U.
- Venue
- Clinical Physiology and Functional Imaging
- Publisher
- Wiley
- Published
- 2007-08-21
- Volume
- 27
- Issue
- 6
- Pages
- 346-353
- ISSN
- 1475-0961 (ISSN-L)
- 1475-097X
- OpenAlex
- W2126891279
- Cited by
- 235
- References
- 26
- FWCI
- 5.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.