The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer
Abstract
Summary: The main aim of this study was to examine the absolute and relative reliability of some commonly used strength imbalance indices such as concentric hamstring‐to‐concentric quadriceps ratio, eccentric hamstring‐to‐concentric quadriceps ratio and bilateral concentric and eccentric strength ratios. An additional aim was to examine the reliability of the peak torque and work of the knee extensor and flexor muscles measured using the Cybex NORM dynamometer. Eighteen physically active healthy subjects (mean ± standard deviation, age 23 ± 3 years, height 176 ± 5 cm, body mass 74 ± 8 kg) were tested three times with 96 h between sessions. Peak torque, average work, unilateral and bilateral ratios were determined at 60, 120, 180 and −60° s−1. Low (0·34) to moderate (0·87) relative reliability (intraclass correlation coefficient, ICC) was found for strength imbalance ratios with eccentric hamstring‐to‐concentric quadriceps ratio showing the greater ICC (>0·80). High ICC values (0·90–0·98) were found for peak torque and average work. Absolute reliability (standard error of measurement) ranged from 3·2% to 8·7% for strength imbalance ratios and from 4·3% to 7·7% for peak torque and average work measurements. This study established the reliability of the most common strength imbalance ratios and of absolute isokinetic muscle strength assessed using the Cybex NORM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
QUANTIFYING TEST-RETEST RELIABILITY USING THE INTRACLASS CORRELATION COEFFICIENT AND THE SEM
WEIR, J. P. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200502000-00038 · Cited by 4,842
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Vincent, W. J. (1994) · Cited by 1,016
Knapik, J. J., Bauman, C. L., Jones, B. H., Harris, J. M., & Vaughan, L. (1991) · The American Journal of Sports Medicine · doi:10.1177/036354659101900113 · Cited by 697
Hamstring Muscle Strain Recurrence and Strength Performance Disorders
Croisier, J.-L., Forthomme, B., Namurois, M.-H., Vanderthommen, M., & Crielaard, J.-M. (2002) · The American Journal of Sports Medicine · doi:10.1177/03635465020300020901 · Cited by 603
Isokinetic Strength and Anaerobic Power of Elite, Subelite and Amateur French Soccer Players
Cometti, G., Maffiuletti, N. A., Pousson, M., Chatard, J.-C., & Maffulli, N. (2001) · International Journal of Sports Medicine · doi:10.1055/s-2001-11331 · Cited by 562
Self-citationA New Concept For Isokinetic Hamstring: Quadriceps Muscle Strength Ratio
Aagaard, P., Simonsen, E. B., Magnusson, S. P., Larsson, B., & Dyhre-Poulsen, P. (1998) · The American Journal of Sports Medicine · doi:10.1177/03635465980260021201 · Cited by 509
Stratford, P. W., & Goldsmith, C. H. (1997) · Physical Therapy · doi:10.1093/ptj/77.7.745 · Cited by 455
Cited by
Eccentric Hamstring Strength and Hamstring Injury Risk in Australian Footballers
Opar, D. A., Williams, M. D., Timmins, R. G., Hickey, J., Duhig, S. J., & Shield, A. J. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000465 · Cited by 390
Opar, D. A., Piatkowski, T., Williams, M. D., & Shield, A. J. (2013) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2013.4837 · Cited by 263
Chen, C.-L., Chen, C.-Y., Liaw, M.-Y., Chung, C.-Y., Wang, C.-J., & Hong, W.-H. (2013) · Osteoporosis International · doi:10.1007/s00198-012-2137-0 · Cited by 74
Chen, C.-L., Hong, W.-H., Cheng, H.-Y. K., Liaw, M.-Y., Chung, C.-Y., & Chen, C.-Y. (2012) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2012.01.017 · Cited by 68
Metadata
- Authors
- Impellizzeri, F. M., Bizzini, M., Rampinini, E., Cereda, F., & Maffiuletti, N. A.
- Venue
- Clinical Physiology and Functional Imaging
- Publisher
- Wiley
- Published
- 2007-12-11
- Volume
- 28
- Issue
- 2
- Pages
- 113-119
- ISSN
- 1475-0961 (ISSN-L)
- 1475-097X
- OpenAlex
- W2139830386
- Cited by
- 279
- References
- 40
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer. https://app.cochat.ai/papers/10.1111/j.1475-097x.2007.00786.x
- The paper
- Impellizzeri, F. M., Bizzini, M., Rampinini, E., Cereda, F., & Maffiuletti, N. A. (2008). Reliability of isokinetic strength imbalance ratios measured using the Cybex NORM dynamometer. Clinical Physiology and Functional Imaging. https://doi.org/10.1111/j.1475-097x.2007.00786.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.