CoChat

Reproducibility and sensitivity of muscle reoxygenation and oxygen uptake recovery kinetics following running exercise in the field

Buchheit, Martin, Ufland, Pierre, Haydar, Bachar, Laursen, Paul B., Ahmaidi, Said · 2011 · Clinical Physiology and Functional Imaging
Cited by 62

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Summary: The purpose of this study was to assess the reliability of postexercise near‐infrared spectroscopy (NIRS)‐derived measurements and their sensitivity to different exercise intensities in the field. Seventeen athletes (24·1 ± 5·6 year) repeated, on three occasions, two 2‐min submaximal shuttle‐runs at 40% and 60% of VIFT (final speed of the 30–15 intermittent fitness test) and a 50‐m shuttle‐run sprint (Sprint), with (OCC) or without (CON) repeated transient arterial occlusions of the medial gastrocnemius during the postexercise period. NIRS variables (i.e. oxyhaemoglobin [HbO 2], deoxyhaemoglobin [HHb] and their difference [Hb diff]) were measured continuously for 3 min after each exercise. Half‐recovery (½Rec) and mean response (MRT; monoexponential curve fitting) times of muscle reoxygenation and muscle oxygen uptake () recovery were calculated. Reliability was assessed using the typical error of measurement, expressed as a coefficient of variation (CV). Postexercise recovery of muscle reoxygenation revealed CVs ranging from 16·8% to 37·3%; CV for recovery ranged from 6·2% to 20·9%, with no substantial differences shown between NIRS variables and exercise intensities. While running, intensity did not affect MRT or ½Rec for muscle reoxygenation, and differences were found for recovery (e.g. [Hb diff]‐ MRT = 28·7 ± 5·2, 34·2 ± 5·1 and 37·3 ± 6·2 s for 40%, 60% and Sprint, respectively, P<0·01). To conclude, the kinetics of postexercise NIRS measurements showed CV values ranging from 6% to 37%, with no substantial differences between exercise intensities or NIRS‐derived variables. However, exercise intensity did influence recovery kinetics, but not that of muscle reoxygenation in an occlusion‐free condition.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1475-097x.2011.01020.x

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 62

Metadata

Authors
Buchheit, M., Ufland, P., Haydar, B., Laursen, P. B., & Ahmaidi, S.
Venue
Clinical Physiology and Functional Imaging
Publisher
Wiley
Published
2011-03-21
Volume
31
Issue
5
Pages
337-346
ISSN
  • 1475-0961 (ISSN-L)
  • 1475-097X
OpenAlex
W2101819959
Cited by
62
References
8
FWCI
13.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.