Computational assessment of drug‐induced effects on the electrocardiogram: from ion channel to body surface potentials
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Background and Purpose: Understanding drug effects on the heart is key to safety pharmacology assessment and anti‐arrhythmic therapy development. Here our goal is to demonstrate the ability of computational models to simulate the effect of drug action on the electrical activity of the heart, at the level of the ion‐channel, cell, heart and ECG body surface potential. Experimental Approach: We use the state‐of‐the‐art mathematical models governing the electrical activity of the heart. A drug model is introduced using an ion channel conductance block for the hERG and fast sodium channels, depending on the IC50 value and the drug dose. We simulate the ECG measurements at the body surface and compare biomarkers under different drug actions. Key Results: Introducing a 50% hERG‐channel current block results in 8% prolongation of the APD90 and 6% QT interval prolongation, hERG block does not affect the QRS interval. Introducing 50% fast sodium current block prolongs the QRS and the QT intervals by 12% and 5% respectively, and delays activation times, whereas APD90 is not affected. Conclusions and Implications: Both potassium and sodium blocks prolong the QT interval, but the underlying mechanism is different: for potassium it is due to APD prolongation; while for sodium it is due to a reduction of electrical wave velocity. This study shows the applicability of in silico models for the investigation of drug effects on the heart, from the ion channel to the ECG‐based biomarkers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Drug induced QT prolongation and torsades de pointes
Yap, Y. G., & Camm, A. J. (2003) · Heart · doi:10.1136/heart.89.11.1363 · Cited by 958 · cited 1×
“The simulations allowed an investigation into the role of I CaL conductance in modulating the action of hERG channel block on ventricular activity and ECG.”
BackgroundVerification of cardiac tissue electrophysiology simulators using an N -version benchmark
Niederer, S. A., Kerfoot, E., Benson, A. P., Bernabeu, M. O., Bernus, O., Bradley, C., Cherry, E. M., Clayton, R., Fenton, F. H., Garny, A., et al. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0139 · Cited by 275
Cited by
The ‘Digital Twin’ to enable the vision of precision cardiology
Corral-Acero, J., Margara, F., Marciniak, M., Rodero, C., Loncaric, F., Feng, Y., Gilbert, A., Fernandes, J. F., Bukhari, H. A., Wajdan, A., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehaa159 · Cited by 932
Self-citationChaste: An Open Source C++ Library for Computational Physiology and Biology
Mirams, G. R., Arthurs, C. J., Bernabeu, M. O., Bordas, R., Cooper, J., Corrias, A., Davit, Y., Dunn, S.-J., Fletcher, A. G., Harvey, D. G., et al. (2013) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1002970 · Cited by 423
Self-citationEvolution of strategies to improve preclinical cardiac safety testing
Gintant, G., Sager, P. T., & Stockbridge, N. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2015.34 · Cited by 407
In silico clinical trials: how computer simulation will transform the biomedical industry
Viceconti, M., Henney, A., & Morley-Fletcher, E. (2016) · International Journal of Clinical Trials · doi:10.18203/2349-3259.ijct20161408 · Cited by 289
Lyon, A., Mincholé, A., Martínez, J. P., Laguna, P., & Rodriguez, B. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0821 · Cited by 228
“They allow personalized simulations of the ECG, 89 allowing the interpretation of the ECG signals (13) (14) (15) as well as the generation of 90 synthetic data for training and validation purposes.”
BackgroundSelf-citationRecent developments in using mechanistic cardiac modelling for drug safety evaluation
Davies, M. R., Wang, K., Mirams, G. R., Caruso, A., Noble, D., Walz, A., Lavé, T., Schuler, F., Singer, T., & Polonchuk, L. (2016) · Drug Discovery Today · doi:10.1016/j.drudis.2016.02.003 · Cited by 66
Self-citationValidation and Trustworthiness of Multiscale Models of Cardiac Electrophysiology
Pathmanathan, P., & Gray, R. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00106 · Cited by 63
“The drug concentration at which Torsades de Pointes is induced in the simulated ECG is the proposed biomarker, and the predictive ability of this biomarker is tested using data for 12 drugs with well-characterized risk.”
BackgroundMethodInfluentialSelf-citationMultiscale Modeling in the Clinic: Drug Design and Development
Clancy, C. E., An, G., Cannon, W. R., Liu, Y., May, E. E., Ortoleva, P., Popel, A. S., Sluka, J. P., Su, J., Vicini, P., et al. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1563-0 · Cited by 62
Mishra, H., Polak, S., Jamei, M., & Rostami‐Hodjegan, A. (2014) · CPT: Pharmacometrics & Systems Pharmacology · doi:10.1038/psp.2014.26 · Cited by 24
Metadata
- Authors
- Zemzemi, N., Bernabeu, M. O., Saiz, J., Cooper, J., Pathmanathan, P., Mirams, G. R., Pitt‐Francis, J., & Rodriguez, B.
- Venue
- British Journal of Pharmacology
- Publisher
- Wiley
- Published
- 2013-01-16
- Volume
- 168
- Issue
- 3
- Pages
- 718-733
- ISSN
- 0007-1188 (ISSN-L)
- 1476-5381
- OpenAlex
- W1912682098
- Cited by
- 109
- References
- 3
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.