The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Non‐invasive assessment of liver fibrosis by stiffness measurement in patients with chronic hepatitis B
Abstract
Background: The need for new non‐invasive tools to assess liver fibrosis in chronic liver diseases has been largely advocated. Liver stiffness measurement (LSM) using transient elastography (FibroScan®, Echosens™) has been shown to be correlated to liver fibrosis in various chronic liver diseases. This study aims to assess its diagnosis accuracy in patients with chronic hepatitis B. Patients and methods: We prospectively enrolled 202 patients with chronic hepatitis B in a multicentre study. Patients underwent liver biopsy (LB) and LSM. METAVIR and Ishak liver fibrosis stages were assessed by two pathologists. Results: LSM or LB was considered unreliable in 29 patients. Statistical analysis was conducted in 173 patients. LSM was significantly (P<0.001) correlated with METAVIR (r=0.65) and Ishak fibrosis stage (0.65). The area under receiver‐operating characteristic curves were 0.81 (95% confidence intervals, 0.73–0.86) for F≥2, 0.93 (0.88–0.96) for F≥3 and 0.93 (0.82–0.98) for F=4. Optimal LSM cut‐off values were 7.2 and 11.0 kPa for F≥2 and F=4, respectively, by maximizing the sum D of sensitivity and specificity, and 7.2 and 18.2 kPa by maximizing the diagnosis accuracy. Conclusion: In conclusion, LSM appears to be reliable for detection of significant fibrosis or cirrhosis in HBV patients and cut‐off values are only slightly different from those observed in HCV patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Histological grading and staging of chronic hepatitis
Ishak, K., Baptista, A., Bianchi, L., Callea, F., De Groote, J., Gudat, F., Denk, H., Desmet, V., Korb, G., MacSween, R. N. M., et al. (1995) · Journal of Hepatology · doi:10.1016/0168-8278(95)80226-6 · Cited by 5,029
Wai, C.-T., Greenson, J. K., Fontana, R. J., Kalbfleisch, J. D., Marrero, J. A., Conjeevaram, H. S., & Lok, A. S.-F. (2003) · Hepatology · doi:10.1053/jhep.2003.50346 · Cited by 4,406
An Algorithm for the Grading of Activity in Chronic Hepatitis C
Bedossa, P., & Poynard, T. (1996) · Hepatology · doi:10.1002/hep.510240201 · Cited by 4,088
Self-citationTransient elastography: a new noninvasive method for assessment of hepatic fibrosis
Sandrin, L., Fourquet, B., Hasquenoph, J.-M., Yon, S., Fournier, C., Mal, F., Christidis, C., Ziol, M., Poulet, B., Kazemi, F., et al. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2003.07.001 · Cited by 2,738
Self-citationCastéra, L., Vergniol, J., Foucher, J., Le Bail, B., Chanteloup, E., Haaser, M., Darriet, M., Couzigou, P., & de Lédinghen, V. (2005) · Gastroenterology · doi:10.1053/j.gastro.2004.11.018 · Cited by 2,487
Self-citationSampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376
Self-citationSampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection
Regev, A., Berho, M. E., Jeffers, L. J., Milikowski, C., Molina, E. G., Pyrsopoulos, N., Feng, Z.-Z., Reddy, K. R., & Schiff, E. R. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04396-4 · Cited by 2,093
Bravo, A. A., Sheth, S. G., & Chopra, S. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440706 · Cited by 2,041
Ziol, M., Handra-Luca, A., Kettaneh, A., Christidis, C., Mal, F., Kazemi, F., de Lédinghen, V., Marcellin, P., Dhumeaux, D., Trinchet, J.-C., et al. (2005) · Hepatology · doi:10.1002/hep.20506 · Cited by 1,470
Self-citationDiagnosis of cirrhosis by transient elastography (FibroScan): a prospective study
Foucher, J. (2006) · Gut · doi:10.1136/gut.2005.069153 · Cited by 1,284
Cited by
EASL Clinical Practice Guidelines: Management of chronic hepatitis B virus infection
European Association for the Study of the Liver (2012) · Journal of Hepatology · doi:10.1016/j.jhep.2012.02.010 · Cited by 2,925
(2015) · Journal of Hepatology · doi:10.1016/j.jhep.2015.04.006 · Cited by 1,875
Non-invasive evaluation of liver fibrosis using transient elastography
Castera, L., Forns, X., & Alberti, A. (2008) · Journal of Hepatology · doi:10.1016/j.jhep.2008.02.008 · Cited by 1,430
EASL Clinical Practice Guidelines: Management of chronic hepatitis B
European Association for the Study of the Liver (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2008.10.001 · Cited by 1,347
Pitfalls of Liver Stiffness Measurement: A 5-Year Prospective Study of 13,369 Examinations
Castéra, L., Foucher, J., Bernard, P.-H., Carvalho, F., Allaix, D., Merrouche, W., Couzigou, P., & de Lédinghen, V. (2010) · Hepatology · doi:10.1002/hep.23425 · Cited by 1,159
Self-citation
Metadata
- Authors
- Marcellin, P., Ziol, M., Bedossa, P., Douvin, C., Poupon, R., De Lédinghen, V., & Beaugrand, M.
- Venue
- Liver International
- Publisher
- Wiley
- Published
- 2009-01-06
- Volume
- 29
- Issue
- 2
- Pages
- 242-247
- ISSN
- 0106-9543 (ISSN-L)
- 1478-3223
- 1478-3231
- OpenAlex
- W2131692102
- Cited by
- 535
- References
- 32
- FWCI
- 38.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non‐invasive assessment of liver fibrosis by stiffness measurement in patients with chronic hepatitis B. https://app.cochat.ai/papers/10.1111/j.1478-3231.2008.01802.x
- The paper
- Marcellin, P., Ziol, M., Bedossa, P., Douvin, C., Poupon, R., De Lédinghen, V., & Beaugrand, M. (2009). Non‐invasive assessment of liver fibrosis by stiffness measurement in patients with chronic hepatitis B. Liver International. https://doi.org/10.1111/j.1478-3231.2008.01802.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.