Boursier, Jérôme, Vergniol, Julien, Sawadogo, Apollinaire, Dakka, Taoufiq, Michalak, Sophie, Gallois, Yves, Le Tallec, Véronique, Oberti, Frédéric, Fouchard‐Hubert, Isabelle, Dib, Nina, Rousselet, Marie Christine, Konaté, Anselme, Amrani, Naïma, De Ledinghen, Victor, Calès, Paul · 2009 · Liver International
Cited by 118

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Background and aims: Blood tests and liver stiffness evaluation (LSE) by ultrasonographic elastometry are accurate tools for diagnosing liver fibrosis. We evaluated whether their synchronous combination in new scores could improve the diagnostic accuracy and reduce liver biopsy requirement in algorithm. Methods: Three hundred and ninety patients with chronic liver disease of miscellaneous causes were included. Five blood fibrosis tests were evaluated: APRI, FIB‐4, Hepascore, Fibrotest and FibroMeter. The reference was fibrosis Metavir staging. Results: Diagnosis of significant fibrosis (Metavir F≥2). The most accurate synchronous combination was FibroMeter+LSE, which provided a significantly higher area under the receiver operating characteristic curve (0.892) than LSE alone (0.867, P=0.011) or Fibrometer (0.834, P<10−3). An algorithm using the FibroMeter+LSE combination and then a liver biopsy in indeterminate cases had 91.9% diagnostic accuracy and required significantly fewer biopsies (20.2%) than previously published Bordeaux algorithm (28.6%, P=0.02) or sequential algorithm for fibrosis evaluation (SAFE) (55.7%, P<10−3). The Angers algorithm performance was not significantly different between viral hepatitis and other causes. Diagnosis of cirrhosis. The most accurate synchronous combination was LSE+FibroMeter, which provided ≥90% predictive values for cirrhosis in 90.6% of patients vs 87.4% for LSE (P=0.02) and 57.9% for FibroMeter (P<10−3). An algorithm including the LSE+FibroMeter combination, and then a liver biopsy in indeterminate cases, had a significantly higher diagnostic accuracy than the SAFE algorithm (91.0 vs 79.8%, P<10−3), and required significantly fewer biopsies than the Bordeaux algorithm (9.3 vs 25.3%, P<10−3). Conclusion: The synchronous combination of a blood test plus LSE improves the accuracy of the non‐invasive diagnosis of liver fibrosis and, consequently, markedly decreases the biopsy requirement in the diagnostic algorithm, notably to <10% in cirrhosis diagnosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1478-3231.2009.02101.x

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 118

Metadata

Authors
Boursier, J., Vergniol, J., Sawadogo, A., Dakka, T., Michalak, S., Gallois, Y., Le Tallec, V., Oberti, F., Fouchard‐Hubert, I., Dib, N., Rousselet, M. C., Konaté, A., Amrani, N., De Ledinghen, V., & Calès, P.
Venue
Liver International
Publisher
Wiley
Published
2009-10
Volume
29
Issue
10
Pages
1507-1515
ISSN
  • 0106-9543 (ISSN-L)
  • 1478-3223
  • 1478-3231
OpenAlex
W2101673499
Cited by
118
References
3
FWCI
9.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The combination of a blood test and Fibroscan improves the non‐invasive diagnosis of liver fibrosis. https://app.cochat.ai/papers/10.1111/j.1478-3231.2009.02101.x
The paper
Boursier, J., Vergniol, J., Sawadogo, A., Dakka, T., Michalak, S., Gallois, Y., Le Tallec, V., Oberti, F., Fouchard‐Hubert, I., Dib, N., Rousselet, M. C., Konaté, A., Amrani, N., De Ledinghen, V., & Calès, P. (2009). The combination of a blood test and Fibroscan improves the non‐invasive diagnosis of liver fibrosis. Liver International. https://doi.org/10.1111/j.1478-3231.2009.02101.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.