Feasibility of liver transient elastography with FibroScan® using a new probe for obese patients: Transient elastography in obese patients

De Lédinghen, Victor, Vergniol, Julien, Foucher, Juliette, El-Hajbi, Farid, Merrouche, Wassil, Rigalleau, Vincent·2010·Liver International

Abstract

BACKGROUND & AIMS: Liver stiffness measurement (LSM) failure when using transient elastography occurs in 2-10% of patients, and is generally related to obesity. The aim of this prospective study was to assess the feasibility of LSM when using a new XL probe on patients with a body mass index (BMI) > or =30 kg/m(2). METHODS: For each patient, LSM was performed using both M probe (currently available and dedicated to patients with standard morphology) and XL probe (dedicated to overweighed patients). A blood sample was taken to assess usual biological variables and simple readily available fibrosis blood tests. RESULTS: Ninety-nine patients were included (27 men, mean age 52 years, mean BMI 40.5 kg/m(2)). LSM was successful (10 valid measurements) in 45% of the cases with the M probe, vs 76% of the cases with the XL probe (P<0.001). Fifty-nine percent of those who could not be measured (<10 valid measurements) using the M probe could successfully be measured using the XL probe. In the 44 patients successfully measured with both probes, LSM was correlated with the platelet count, prothrombin time, gamma-glutamyltransferase, aspartate aminotransferase, fasting glucose, AST platelet ratio index, Forns score and FIB-4. CONCLUSION: The new XL probe allows providing a higher rate of LSM than the M probe in patients with an increased BMI and shows promising results for the evaluation of liver fibrosis.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1478-3231.2010.02258.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 205

Metadata

Authors
De Lédinghen, V., Vergniol, J., Foucher, J., El-Hajbi, F., Merrouche, W., & Rigalleau, V.
Venue
Liver International
Publisher
Wiley
Published
2010-02-05
Volume
30
Issue
7
Pages
1043-1048
ISSN
  • 0106-9543 (ISSN-L)
  • 1478-3223
  • 1478-3231
OpenAlex
W1897424852
Cited by
205
References
2
FWCI
14.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility of liver transient elastography with FibroScan® using a new probe for obese patients: Transient elastography in obese patients. https://app.cochat.ai/papers/10.1111/j.1478-3231.2010.02258.x
The paper
De Lédinghen, V., Vergniol, J., Foucher, J., El-Hajbi, F., Merrouche, W., & Rigalleau, V. (2010). Feasibility of liver transient elastography with FibroScan® using a new probe for obese patients: Transient elastography in obese patients. Liver International. https://doi.org/10.1111/j.1478-3231.2010.02258.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.