Inadequacy of Dipstick Proteinuria in Hypertensive Pregnancy
The DOI matches its Crossref record.
Abstract
EDITORIAL COMMENT": It is absolutely essential with regard to patient management to know whether an antenatal patient with hypertension and/or generalized oedema has proteinuria. There is always the problem of contamination of urine and hence the need for a careful mid‐stream specimen or a catheter specimen of urine rather than sending a patient home who has significant proteinuria and hence the risk of developing severe preeclampsia or eclampsia. A useful method to obtain a quick answer is to acidify the urine and boil in a test tube and allow to stand in a rack for 30 minutes when the amount of protein deposited can be assessed in terms of the whole volume of the specimen. When the protein is ‘solid'there is no visible urine above the precipitate while with ‘half‐solid protein'the latter occupies one‐half of the total urine depth. Qualitatively protein ‘half‐solid'corresponds to 10–12 g/JL Although dipsticks are used widely in all antenatal clinics there is still a place for boiling urine to decide whether or not a patient requires admission to hospital as she certainly does when she has hypertension associated with significant proteinuria. After the woman has been admitted to hospital a 24‐hour urine specimen should be collected to quantify the proteinuria. Authors' Response to Editorial Comment: We agree entirely that one cannot overestimate the importance of detecting true proteinuria in hypertensive pregnant women. The thrust of our manuscript was to emphasize the inherent inaccuracies in dipstick testing when compared with 24‐hour‐urine protein quantitation as the gold standard. On the basis of this work alone we would not recommend routine use of boiling urine ‐ to our knowledge no study has compared the relative accuracy of dipstick testing and boiling precipitation methods in pregnant women and it is widely recognized that both methods have their false negatives and false positives. Some authorities believe that “bedside ” precipitation techniques are outdated, stating that ‘old screening methods such as boiling the urine or detecting urine turbidity by eye after adding salicylsulphonic acid or trichloroacetic acid are much less reliable than the test strip’ (Mallich NP, Short CD. The clinical approach to haematuria and proteinuria, in: Cameron S, Davison AM, Grundfeld JP, Kerr D, Ritz E (eds). Oxford Textbook of Clinical Nephrology. Oxford Medical Publications. Oxford 1992: 227–228. The message we wish to convey from this research is that once proteinuria has been ‘detected’ by a screening method (in this study dipstick testing) 24‐hour‐urine protein estimation is generally required to be certain about the significance of the screening test. Here we also agree with the Editorial Comment. Hopefully an accurate, reproducible and more convenient system of detecting proteinuria in pregnancy will be developed in the years to come. Summary: The objective of this study was to determine the accuracy of ward urinalysis and the sensitivity of dipstick testing in the assessment of proteinuria in hypertensive pregnant women. Subjects were 230 consecutive hypertensive pregnant women who were admitted to hospital over a 2‐year period. Routine ward urinalyses for protein, obtained on a mid‐stream sample before and after a 24‐hour urine collection for quantitating proteinuria, were compared with the 24‐hour urine protein excretion. As a control for dipstick accuracy, urinalysis was also performed on a mixed aliquot of each of the 24‐hour samples by a single observer experienced in urinalysis. True proteinuria was considered as > 300 mg/day. The positive predictive value for urinalysis ranged from 38% (for the precollection test) to 60% (for tests on the aliquot). Negative predictive values were 86–88%. The false negative rates at ‘nil’ or ‘trace’ proteinuria ranged from 8–18%. The false positive rates at 3+ (3 g/L) or 4+ (≥ 20 g/L) ranged from 0–17%, at 2+ (1 g/L) from 18–50% and at 1+(0.3 g/L) from 67–83%. Best results for urinalysis were obtained on the aliquot testing but even under these ideal circumstances there was a high false positive rate (67%) at 1+ (0.3 g/L) urinalysis level. These studies show that in routine clinical practice ‘nil’ or ‘trace’ proteinuria will miss significant proteinuria in approximately 1 out of 8 hypertensive pregnant women while 3+(3 g/L) or 4+(520 g/L) will rarely be a false positive. At urinalysis of 1+ or 2+ a 24‐hour urine collection is required to be certain about the presence or absence of proteinuria. Research studies should demand 24‐hour urine protein quantitation and not rely solely upon urinalysis results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Steegers, E. A., von Dadelszen, P., Duvekot, J. J., & Pijnenborg, R. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60279-6 · Cited by 2,850
Carroli, G., Rooney, C., & Villar, J. (2001) · Paediatric and Perinatal Epidemiology · doi:10.1046/j.1365-3016.2001.0150s1001.x · Cited by 622
RETIRED: Diagnosis, Evaluation, and Management of the Hypertensive Disorders of Pregnancy
Magee, L. A., Helewa, M., Rey, E., Cardew, S., Côté, A.-M., Douglas, M. J., Firoz, T., Gibson, P. S., Gruslin A., A., Lange, I., et al. (2008) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(16)32776-1 · Cited by 578
SOMANZ guidelines for the management of hypertensive disorders of pregnancy 2014
Lowe, S. A., Bowyer, L., Lust, K., McMahon, L. P., Morton, M., North, R. A., Paech, M., & Said, J. M. (2015) · Australian and New Zealand Journal of Obstetrics and Gynaecology · doi:10.1111/ajo.12399 · Cited by 299
Côté, A.-M., Brown, M. A., Lam, E., Dadelszen, P. V., Firoz, T., Liston, R. M., & Magee, L. A. (2008) · BMJ · doi:10.1136/bmj.39532.543947.be · Cited by 235
Self-citation
Metadata
- Authors
- Brown, M. A., & Buddie, M. L.
- Venue
- Australian and New Zealand Journal of Obstetrics and Gynaecology
- Publisher
- Wiley
- Published
- 1995-11
- Volume
- 35
- Issue
- 4
- Pages
- 366-369
- ISSN
- 0004-8666 (ISSN-L)
- 1479-828X
- OpenAlex
- W2036494924
- Cited by
- 86
- References
- 0
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Inadequacy of Dipstick Proteinuria in Hypertensive Pregnancy. https://app.cochat.ai/papers/10.1111/j.1479-828x.1995.tb02143.x
- The paper
- Brown, M. A., & Buddie, M. L. (1995). Inadequacy of Dipstick Proteinuria in Hypertensive Pregnancy. Australian and New Zealand Journal of Obstetrics and Gynaecology. https://doi.org/10.1111/j.1479-828x.1995.tb02143.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.