Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 235

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Diagnostic accuracy of urinary spot protein:creatinine ratio for proteinuria in hypertensive pregnant women: systematic review

Open access
Côté, Anne-Marie, Brown, Mark A, Lam, Elaine, Dadelszen, Peter von, Firoz, Tabassum, Liston, Robert M, Magee, Laura A·2008·BMJ

Abstract

OBJECTIVE: To review the spot protein:creatinine ratio and albumin:creatinine ratio as diagnostic tests for significant proteinuria in hypertensive pregnant women. DESIGN: Systematic review. DATA SOURCES: Medline and Embase, the Cochrane Library, reference lists, and experts. Review methods Literature search (1980-2007) for articles of the spot protein:creatinine ratio or albumin:creatinine ratio in hypertensive pregnancy, with 24 hour proteinuria as the comparator. RESULTS: 13 studies concerned the spot protein:creatinine ratio (1214 women with primarily gestational hypertension). Nine studies reported sensitivity and specificity for eight cut-off points, median 24 mg/mmol (range 17-57 mg/mmol; 0.15-0.50 mg/mg). Laboratory assays were not well described. Diagnostic test characteristics were recalculated for a cut-off point of 30 mg/mmol. No significant heterogeneity in cut-off points was found between studies over a range of proteinuria. Pooled values gave a sensitivity of 83.6% (95% confidence interval 77.5% to 89.7%), specificity of 76.3% (72.6% to 80.0%), positive likelihood ratio of 3.53 (2.83 to 4.49), and negative likelihood ratio of 0.21 (0.13 to 0.31) (nine studies, 1003 women). Two studies of the spot albumin:creatinine ratio (225 women) found optimal cut-off points of 2 mg/mmol for proteinuria of 0.3 g/day or more and 27 mg/mmol for albuminuria. CONCLUSION: The spot protein:creatinine ratio is a reasonable "rule-out" test for detecting proteinuria of 0.3 g/day or more in hypertensive pregnancy. Information on use of the albumin:creatinine ratio in these women is insufficient.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.39532.543947.be

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 235

Metadata

Authors
Côté, A.-M., Brown, M. A., Lam, E., Dadelszen, P. V., Firoz, T., Liston, R. M., & Magee, L. A.
Venue
BMJ
Publisher
BMJ
Published
2008-04-10
Volume
336
Issue
7651
Pages
1003-1006
ISSN
  • 1756-1833 (ISSN-L)
  • 0959-8138
OpenAlex
W1998442968
Cited by
235
References
4
FWCI
2.16
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Diagnostic accuracy of urinary spot protein:creatinine ratio for proteinuria in hypertensive pregnant women: systematic review. https://app.cochat.ai/papers/10.1136/bmj.39532.543947.be
The paper
Côté, A.-M., Brown, M. A., Lam, E., Dadelszen, P. V., Firoz, T., Liston, R. M., & Magee, L. A. (2008). Diagnostic accuracy of urinary spot protein:creatinine ratio for proteinuria in hypertensive pregnant women: systematic review. BMJ. https://doi.org/10.1136/bmj.39532.543947.be

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.