Urine protein profiling with surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
BACKGROUND In the last few years there has been an increasing interest in exploring the human proteome. In particular, efforts have focused on developing strategies to generate reproducible protein maps of normal cells, tissues, and biologic fluids, from which studies can then compare protein expression between different groups (e.g., healthy individuals vs. those with a specific pathologic state). METHODS Various extrinsic factors (instrument settings, matrix composition, urine storage post void, freeze-thaw cycles) and intrinsic factors (blood in urine, urine dilution, first-void vs. midstream urine) were analyzed with respect to their impact on urine protein profiling using surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS). RESULTS Extrinsic factors that critically influenced reproducibility and peak detection of urine protein profiling were matrix composition and instrument settings, while freeze-thaw cycles had minimal impact. Midstream urines samples did not undergo changes in their protein profile when stored for three days at 4 degrees C. Intrinsic factors that influenced normal urine protein profiling were blood in the urine and urine dilution. Female first-void urine had a significantly different ratio of proteins present compared to a midstream urine sample. Limitations of the SELDI-TOF-MS technique included ion suppression and quantification of individual proteins when protein composition was complex. CONCLUSION SELDI-TOF-MS offers a unique platform for high throughput urine protein profiling; however, standardization of analysis conditions is critical, and both extrinsic and intrinsic factors must be taken into account for accurate data interpretation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Contribution of Human α-Defensin 1, 2, and 3 to the Anti-HIV-1 Activity of CD8 Antiviral Factor
Zhang, L., Yu, W., He, T., Yu, J., Caffrey, R. E., Dalmasso, E. A., Fu, S., Pham, T., Mei, J., Ho, J. J., et al. (2002) · Science · doi:10.1126/science.1076185 · Cited by 468
RetractedQuantitative analysis of complex protein mixtures using isotope-coded affinity tags
Gygi, S. P., Rist, B., Gerber, S. A., Turecek, F., Gelb, M. H., & Aebersold, R. (1999) · Nature Biotechnology · doi:10.1038/13690 · Cited by 4,683 · cited 1×
“While this technique provides information about the protein content of the samples, little information about their relative abundance can be obtained unless the proteins/peptides are labeled first by isotope-coded affinity tags [8, 9] or other protein/peptide labeling techniques.”
Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers.
Hillenkamp, F., Karas, M., Beavis, R. C., & Chait, B. T. (1991) · Analytical Chemistry · doi:10.1021/ac00024a716 · Cited by 1,930 · cited 1×
“Matrix allows for efficient ionization and vaporization of proteins [10].”
BackgroundHanash, S. (2003) · Nature · doi:10.1038/nature01514 · Cited by 900
Quantitative proteome analysis by solid-phase isotope tagging and mass spectrometry
Zhou, H., Ranish, J. A., Watts, J. D., & Aebersold, R. (2002) · Nature Biotechnology · doi:10.1038/nbt0502-512 · Cited by 384
Thongboonkerd, V., Mcleish, K. R., Arthur, J. M., & Klein, J. B. (2002) · Kidney International · doi:10.1111/j.1523-1755.2002.kid565.x · Cited by 359 · cited 1×
“In recent literature, Thongboonkerd et al [5] identified 67 protein forms of 47 unique proteins in normal urine by 2-DE.”
BackgroundSpahr, C. S., Davis, M. T., McGinley, M. D., Robinson, J. H., Bures, E. J., Beierle, J., Mort, J., Courchesne, P. L., Chen, K., Wahl, R. C., et al. (2001) · PROTEOMICS · doi:10.1002/1615-9861(200101)1:1<93::aid-prot93>3.0.co;2-3 · Cited by 309
Renal handling of albumin: A critical review of basic concepts and perspective
Russo, L. M., Bakris, G. L., & Comper, W. D. (2002) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2002.32764 · Cited by 209
Knepper, M. A. (2002) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000014782.37591.c7 · Cited by 118
Toward Proteomics in Uroscopy: Urinary Protein Profiles after Radiocontrast Medium Administration
Hampel, D. J., Sansome, C., SHA, M., Brodsky, S. V., Lawson, W. E., & Goligorsky, M. S. (2001) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1251026 · Cited by 104
Schultz, C. J., Dalton, R. N., Turner, C., Neil, H. A. W., Dunger, D. B., & For The Oxford Regional Prospective Study Group (2000) · Diabetic Medicine · doi:10.1046/j.1464-5491.2000.00200.x · Cited by 96
Cutillas, P. R., Norden, A. G. W., Cramer, R., Burlingame, A. L., & Unwin, R. J. (2003) · Clinical Science · doi:10.1042/cs20020342 · Cited by 87
Stability of Common Analytes in Urine Refrigerated for 24 h before Automated Analysis by Test Strips
Froom, P., Bieganiec, B., Ehrenrich, Z., & Barak, M. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.9.1384 · Cited by 56
Sodium loading changes urinary protein excretion: a proteomic analysis
Thongboonkerd, V., Klein, J. B., Pierce, W. M. J., Jevans, A. W., & Arthur, J. M. (2003) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00140.2002 · Cited by 50
The Antimicrobial Defense Mechanism of the Female Urethra: A Reassessment
Kunin, C. M., Evans, C. D., Bartholomew, D. A., & Bates, D. G. (2002) · The Journal of Urology · doi:10.1016/s0022-5347(05)64649-6 · Cited by 40
Innanen, V. T., Groom, B. M., & de Campos, F. M. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.6.1093 · Cited by 26
Postexercise Proteinuria in Childhood and Adolescence
Poortmans, J.-R., Geudvert, C., Schorokoff, K., & Plaen, P. D. (1996) · International Journal of Sports Medicine · doi:10.1055/s-2007-972876 · Cited by 21
Cited by
Human body fluid proteome analysis
Hu, S., Loo, J. A., & Wong, D. T. (2006) · PROTEOMICS · doi:10.1002/pmic.200600284 · Cited by 533
Decramer, S., de Peredo, A. G., Breuil, B., Mischak, H., Monsarrat, B., Bascands, J.-L., & Schanstra, J. P. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r800001-mcp200 · Cited by 450
Discovery of Urinary Biomarkers
Pisitkun, T., Johnstone, R., & Knepper, M. A. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r600004-mcp200 · Cited by 405
Biospecimen Reporting for Improved Study Quality (BRISQ)
Moore, H. M., Kelly, A. B., Jewell, S. D., McShane, L. M., Clark, D. P., Greenspan, R., Hayes, D. F., Hainaut, P., Kim, P., Mansfield, E., et al. (2011) · Journal of Proteome Research · doi:10.1021/pr200021n · Cited by 337
Coombes, K. R., Tsavachidis, S., Morris, J. S., Baggerly, K. A., Hung, M., & Kuerer, H. M. (2005) · PROTEOMICS · doi:10.1002/pmic.200401261 · Cited by 328
Metadata
- Authors
- Schaub, S., Wilkins, J., Weiler, T., Sangster, K., Rush, D., & Nickerson, P.
- Venue
- Kidney International
- Publisher
- Elsevier BV
- Published
- 2004-01
- Volume
- 65
- Issue
- 1
- Pages
- 323-332
- ISSN
- 0085-2538 (ISSN-L)
- OpenAlex
- W2051674059
- Cited by
- 328
- References
- 17
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.