Hemodialysis-associated hypotension as an independent risk factor for two-year mortality in hemodialysis patients
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
BACKGROUND The relationship between blood pressure (BP) and mortality in hemodialysis patients has remained controversial. Some studies suggested that a lower pre- or postdialysis BP was associated with excess mortality, while others showed poorer outcome in patients with uncontrolled hypertension. We conducted a multicenter prospective cohort study to evaluate the impact of hemodialysis-associated hypotension on mortality. METHODS We recruited 1244 patients (685 males; mean age, 60 +/- 13 years) who underwent hemodialysis in 28 units during the two-year study period beginning in December 1999. Pre-, intra-, and postdialysis BP, and BP upon standing soon after hemodialysis, were measured in all patients at entry. Logistic regression analysis was used to assess the effect on mortality of pre-, intra-, and postdialysis BP, a fall in BP during hemodialysis, and a fall in BP upon standing soon after hemodialysis. RESULTS During the study period, 149 patients died. Logistic models identified the lowest intradialysis systolic blood pressure (SBP) and degree of fall in SBP upon standing soon after hemodialysis as significant factors affecting mortality, but not pre- or postdialysis SBP and diastolic BP. The adjusted odds ratio for death was 0.79 (95% CI 0.64-0.98) when the lowest intradialysis SBP was analyzed in increments of 20 mm Hg, and was 0.82 (95% CI 0.67-0.98) when the fall in SBP upon standing soon after hemodialysis was analyzed in increments of 10 mm Hg. CONCLUSION These results suggest that intradialysis hypotension and orthostatic hypotension after hemodialysis are significant and independent factors affecting mortality in hemodialysis patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Survival as an index of adequacy of dialysis
Charra, B., Calemard, E., Ruffet, M., Chazot, C., Terrat, J.-C., Vanel, T., & Laurent, G. (1992) · Kidney International · doi:10.1038/ki.1992.191 · Cited by 756
“U” curve association of blood pressure and mortality in hemodialysis patients
Zager, P. G., Nikolic, J., Brown, R. H., Campbell, M. A., Hunt, W. C., Peterson, D., Van Stone, J., Levey, A., Meyer, K. B., Klag, M. J., et al. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.00005.x · Cited by 662
Oxford Textbook of Clinical Nephrology: Three-Volume Pack
(2015) · doi:10.1093/med/9780199592548.001.0001 · Cited by 511
Port, F. K., Hulbert-Shearon, T. E., Wolfe, R. A., Bloembergen, W. E., Golper, T. A., Agodoa, L. Y. C., & Young, E. W. (1999) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(99)70188-5 · Cited by 451
Association Between Pulse Pressure and Mortality in Patients Undergoing Maintenance Hemodialysis
Klassen, P. S. (2002) · JAMA · doi:10.1001/jama.287.12.1548 · Cited by 392
Dialysis hypotension: A hemodynamic analysis
Daugirdas, J. T. (1991) · Kidney International · doi:10.1038/ki.1991.28 · Cited by 334
Tozawa, M., Iseki, K., Iseki, C., & Takishita, S. (2002) · Kidney International · doi:10.1046/j.1523-1755.2002.00173.x · Cited by 199
Iseki, K., Miyasato, F., Tokuyama, K., Nishime, K., Uehara, H., Shiohira, Y., Sunagawa, H., Yoshihara, K., Yoshi, S., Toma, S., et al. (1997) · Kidney International · doi:10.1038/ki.1997.165 · Cited by 167
Survival and predictors of death in dialysed diabetic patients
Koch, M., Thomas, B., Tschöpe, W., & Ritz, E. (1993) · Diabetologia · doi:10.1007/bf02374508 · Cited by 146
Report on the annual statistical survey of the Japanese Society for Dialysis Therapy in 1996
Shinzato, T., Nakai, S., Akiba, T., Yamagami, S., Yamazaki, C., Kitaoka, T., Kubo, K., Maeda, K., & Morii, H. (1999) · Kidney International · doi:10.1046/j.1523-1755.1999.00297.x · Cited by 111
Cited by
Dialysis Dose and Intradialytic Hypotension: Results from the HEMO Study
Mc Causland, F. R., Brunelli, S. M., & Waikar, S. S. (2013) · American Journal of Nephrology · doi:10.1159/000355958 · Cited by 2,690
The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2019)
Umemura, S., Arima, H., Arima, S., Asayama, K., Dohi, Y., Hirooka, Y., Horio, T., Hoshide, S., Ikeda, S., Ishimitsu, T., et al. (2019) · Hypertension Research · doi:10.1038/s41440-019-0284-9 · Cited by 1,880
on behalf of The Japanese Society of Hypertension Committee for Guidelines for the Management of Hypertension, Ogihara, T., Kikuchi, K., Matsuoka, H., Fujita, T., Higaki, J., Horiuchi, M., Imai, Y., Imaizumi, T., Ito, S., et al. (2014) · Hypertension Research · doi:10.1038/hr.2014.68 · Cited by 1,385
Hemodialysis-Induced Cardiac Injury: Determinants and Associated Outcomes
Burton, J. O., Jefferies, H. J., Selby, N. M., & McIntyre, C. W. (2009) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03900808 · Cited by 686
Rapid fluid removal during dialysis is associated with cardiovascular morbidity and mortality
Flythe, J. E., Kimmel, S. E., & Brunelli, S. M. (2011) · Kidney International · doi:10.1038/ki.2010.383 · Cited by 501
Heerspink, H. J. L., Ninomiya, T., Zoungas, S., de Zeeuw, D., Grobbee, D. E., Jardine, M. J., Gallagher, M., Roberts, M. A., Cass, A., Neal, B., et al. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60212-9 · Cited by 430
Intradialytic Hypotension and Risk of Cardiovascular Disease
Stefánsson, B. V., Brunelli, S. M., Cabrera, C., Rosenbaum, D., Anum, E., Ramakrishnan, K., Jensen, D. E., & Stålhammar, N.-O. (2014) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.02680314 · Cited by 333
Flythe, J. E., Chang, T. I., Gallagher, M. P., Lindley, E., Madero, M., Sarafidis, P. A., Unruh, M. L., Wang, A. Y.-M., Weiner, D. E., Cheung, M., et al. (2020) · Kidney International · doi:10.1016/j.kint.2020.01.046 · Cited by 278
Clinical practice guideline exercise and lifestyle in chronic kidney disease
Baker, L. A., March, D. S., Wilkinson, T. J., Billany, R. E., Bishop, N. C., Castle, E. M., Chilcot, J., Davies, M. D., Graham-Brown, M. P. M., Greenwood, S. A., et al. (2022) · BMC Nephrology · doi:10.1186/s12882-021-02618-1 · Cited by 248
Intradialytic Hypotension and Vascular Access Thrombosis
Chang, T. I., Paik, J., Greene, T., Desai, M., Bech, F., Cheung, A. K., & Chertow, G. M. (2011) · Journal of the American Society of Nephrology · doi:10.1681/asn.2010101119 · Cited by 219
“0001 Dialysis session minimum (mmHg) SBP (SD) 126 (18) 122 (18) 119 (17) 108 (16) 0.”
Inrig, J. K., Patel, U. D., Toto, R. D., & Szczech, L. A. (2009) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2009.05.012 · Cited by 195
“While intradialytic hypotension is a common well-recognized complication of HD associated with adverse outcomes(1), intradialytic increases in BP can occur in up to 15% of prevalent HD patients and is also associated with adverse short-term outcomes.”
BackgroundDiabetes and end-stage renal disease; a review article on new concepts.
Ghaderian, S. B., Hayati, F., Shayanpour, S., & Mousavi, S. S. B. (2015) · PubMed · doi:10.12861/jrip.2015.07 · Cited by 192
Relationship between Hypotension and Cerebral Ischemia during Hemodialysis
MacEwen, C., Sutherland, S., Daly, J., Pugh, C., & Tarassenko, L. (2017) · Journal of the American Society of Nephrology · doi:10.1681/asn.2016060704 · Cited by 189
Davenport, A., Cox, C., & Thuraisingham, R. (2008) · Kidney International · doi:10.1038/sj.ki.5002745 · Cited by 189
A systematic review of the clinical effects of reducing dialysate fluid temperature
Selby, N. M., & McIntyre, C. W. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfl126 · Cited by 184
“It is also recognized that a fall in blood pressure during dialysis predicts mortality [ 2 ].”
BackgroundNeurological complications of chronic kidney disease
Krishnan, A. V., & Kiernan, M. C. (2009) · Nature Reviews Neurology · doi:10.1038/nrneurol.2009.138 · Cited by 182
Effects of hemodialysis on cardiac function
McIntyre, C. W. (2009) · Kidney International · doi:10.1038/ki.2009.207 · Cited by 175
Chou, J. A., Streja, E., Nguyen, D. V., Rhee, C. M., Obi, Y., Inrig, J. K., Amin, A., Kovesdy, C. P., Sim, J. J., & Kalantar-Zadeh, K. (2018) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfx037 · Cited by 167
“Nadir-based definitions of IDH were more strongly associated with mortality rather than the change in intradialytic SBP (DiSBP), whereas previous studies [6, 16, 17] showed mixed associations with DiSBP and frequency of IDH with mortality.”
BackgroundResultZhao, Y., & Chen, Y. (2020) · Seminars in Dialysis · doi:10.1111/sdi.12861 · Cited by 35
Construction of nursing‐sensitive quality indicators for haemodialysis using Delphi method
Gao, J., Liu, X., Che, W., & Xin, X. (2018) · Journal of Clinical Nursing · doi:10.1111/jocn.14607 · Cited by 29
Metadata
- Authors
- Shoji, T., Tsubakihara, Y., Fujii, M., & Imai, E.
- Venue
- Kidney International
- Publisher
- Elsevier BV
- Published
- 2004-09
- Volume
- 66
- Issue
- 3
- Pages
- 1212-1220
- ISSN
- 0085-2538 (ISSN-L)
- OpenAlex
- W2089177095
- Cited by
- 653
- References
- 12
- FWCI
- 7.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.