The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Extending the applicability of the Raman carbonaceous‐material geothermometer using data from contact metamorphic rocks
Abstract
The degree of graphitization of carbonaceous material (CM) has been widely used as an indicator of metamorphic grade. Previous work has demonstrated that peak metamorphic temperature (T) of regional metamorphic rocks can be estimated by an area ratio (R2) of peaks recognized in Raman spectra of CM. The applicability of this method to low‐pressure (<3 kbar) contact metamorphism was tested using Raman spectroscopic analyses of samples from two contact‐metamorphic aureoles in Japan (Daimonji and Kasuga areas). A suitable measurement procedure allows the dependence of the geothermometer on sample type (thin section, chip) and incident angle of laser beam relative to the c‐axes of CM to be tested. Two important general results are: (i) in addition to standard thin sections, chips are also suitable for spectral analysis; and (ii) the incident angle of the laser beam does not significantly affect the temperature estimation, i.e. spectral measurements for the geothermometer can be carried out irrespective of the crystallographic orientation. A laser wavelength of 532 nm was used in this study compared with 514.5 nm in an independent previous study. A comparison shows that the use of a 532‐nm laser results in a slightly, but systematically larger R2 ratio than that of a 514.5‐nm laser. Taking this effect into account, our results show that there is a slight but distinct difference between the R2–T correlations shown by contact and regional metamorphic rocks: the former are slightly better‐crystallized (have slightly lower R2 values) than the latter at the same temperature. This difference is interpreted as due to the degree of associated deformation. Despite the slight difference, the results of this study coincide within the estimated errors of ±50 °C with those of the previously proposed Raman CM geothermometer, thus demonstrating the applicability of this method to contact metamorphism. To facilitate more precise temperature estimates in regions of contact metamorphism, a new calibration for analyses using a 532‐nm laser is derived. Another important observation is that the R2 ratio of metamorphosed CM in pelitic and psammitic rocks is highly heterogeneous with respect to a single sample. To obtain a reliable temperature estimate, the average R2 value must be determined by using a substantial number of measurements (usually N > 50) that adequately reflects the range of sample heterogeneity. Using this procedure (with 532‐nm laser) and adapting our new calibration, the errors of the Raman CM geothermometer for contact metamorphic rocks decrease to ∼±30 °C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Carslaw, H. S., & Jaeger, J. C. (1947) · International Linear Collider · Cited by 19,877
Tranter, C. J. (1959) · Journal of the Mechanics and Physics of Solids · doi:10.1016/0022-5096(59)90029-8 · Cited by 18,388
Tuinstra, F., & Koenig, J. L. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1674108 · Cited by 10,717
Studying disorder in graphite-based systems by Raman spectroscopy
Pimenta, M. A., Dresselhaus, G., Dresselhaus, M. S., Cançado, L. G., Jorio, A., & Saito, R. (2007) · Phys. Chem. Chem. Phys. · doi:10.1039/b613962k · Cited by 4,623
First- and second-order Raman scattering from finite-size crystals of graphite
Nemanich, R. J., & Solin, S. A. (1979) · Physical Review B · doi:10.1103/physrevb.20.392 · Cited by 2,109
(1993) · Medical Entomology and Zoology · Cited by 2,074
Raman spectroscopy of carbon materials: structural basis of observed spectra
Wang, Y., Alsmeyer, D. C., & McCreery, R. L. (1990) · Chemistry of Materials · doi:10.1021/cm00011a018 · Cited by 1,727
Creep of Crystals: High-Temperature Deformation Processes in Metals, Ceramics and Minerals
Poirier, J.-P. (1985) · Cambridge University Press eBooks · doi:10.1017/cbo9780511564451 · Cited by 1,445
Raman spectra of carbonaceous material in metasediments: a new geothermometer
Beyssac, O., Goffé, B., Chopin, C., & Rouzaud, J. N. (2002) · Journal of Metamorphic Geology · doi:10.1046/j.1525-1314.2002.00408.x · Cited by 1,247
Origin of dispersive effects of the RamanDband in carbon materials
Matthews, M. J., Pimenta, M. A., Dresselhaus, G., Dresselhaus, M. S., & Endo, M. (1999) · Physical Review B · doi:10.1103/physrevb.59.r6585 · Cited by 999
Cited by
Kouketsu, Y., Mizukami, T., Mori, H., Endo, S., Aoya, M., Hara, H., Nakamura, D., & Wallis, S. (2014) · Island Arc · doi:10.1111/iar.12057 · Cited by 461
Self-citationHenry, D. G., Jarvis, I., Gillmore, G., & Stephenson, M. (2019) · Earth-Science Reviews · doi:10.1016/j.earscirev.2019.102936 · Cited by 324
Grobe, A., von Hagke, C., Littke, R., Dunkl, I., Wübbeler, F., Muchez, P., & Urai, J. L. (2019) · Solid Earth · doi:10.5194/se-10-149-2019 · Cited by 71
Grobe, A., Urai, J. L., Littke, R., & Lünsdorf, N. K. (2016) · International Journal of Coal Geology · doi:10.1016/j.coal.2016.02.007 · Cited by 21
Metadata
- Authors
- AOYA, M., KOUKETSU, Y., ENDO, S., SHIMIZU, H., MIZUKAMI, T., NAKAMURA, D., & WALLIS, S.
- Venue
- Journal of Metamorphic Geology
- Publisher
- Wiley
- Published
- 2010-08-25
- Volume
- 28
- Issue
- 9
- Pages
- 895-914
- ISSN
- 0263-4929 (ISSN-L)
- 1525-1314
- OpenAlex
- W2111375088
- Cited by
- 296
- References
- 38
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Extending the applicability of the Raman carbonaceous‐material geothermometer using data from contact metamorphic rocks. https://app.cochat.ai/papers/10.1111/j.1525-1314.2010.00896.x
- The paper
- AOYA, M., KOUKETSU, Y., ENDO, S., SHIMIZU, H., MIZUKAMI, T., NAKAMURA, D., & WALLIS, S. (2010). Extending the applicability of the Raman carbonaceous‐material geothermometer using data from contact metamorphic rocks. Journal of Metamorphic Geology. https://doi.org/10.1111/j.1525-1314.2010.00896.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.