Multi‐Field Surface Electrode for Selective Electrical Stimulation
The DOI matches its Crossref record.
Abstract
We designed a 24‐field array and an on‐line control box that selects which and how many of 24 fields will conduct electrical charge during functional electrical stimulation. The array was made using a conductive microfiber textile, silver two‐component adhesive, and the conductive ink imprint on the polycarbonate. The control box comprised 24 switches that corresponded one‐to‐one to the fields on the array. Each field could be made conductive or nonconductive by simple pressing of the corresponding push‐button type switch on the control box. We present here representative results of the selectivity of the new electrode measured in three tetraplegic patients during functional electrical stimulation of the forearm. The task was to generate finger flexion and extension with minimal interference of the wrist movement during lateral and palmar grasps. Therapists determined the appropriate pattern that lead to effective grasping, lasting on average 5 min per stimulation channel in the first session. This optimal conductive pattern (size and shape) provided effective finger flexion and extension with minimal wrist flexion/extension and ulnar/radial deviations (<10 degrees). The optimal size and shape of the electrode in all cases had a branched pattern. The selection of the optimal stimulation site was achieved without moving the electrode. The size and shape were reproducible in the same subject from session to session, yet were different from subject to subject. The optimal electrode size and shape changed when subjects pronated and supinated their forearm. The control box includes a program that can dynamically change the number and sites of the conductive fields; hence, it is feasible to use this during functional movements. Subjects learned how to determine the optimal electrode pattern; hence, these electrodes could be effective for home usage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrical stimulation for the suppression of pathological tremor
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0803-6 · Cited by 129
Self-citationRupp, R., Rohm, M., Schneiders, M., Kreilinger, A., & Muller-Putz, G. R. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2395253 · Cited by 84
“[29] A.”
On the Use of Fixed‐Intensity Functional Electrical Stimulation for Attenuating Essential Tremor
Bó, A. P. L., Azevedo‐Coste, C., Geny, C., Poignet, P., & Fattal, C. (2014) · Artificial Organs · doi:10.1111/aor.12261 · Cited by 40
Biomechanical loading as an alternative treatment for tremor: a review of two approaches
Rocon, E., Gallego, J. Á., Belda-Lois, J. M., Benito-León, J., & Pons, J. L. (2012) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.107 · Cited by 26
Metadata
- Authors
- Popović‐Bijelić, A., Bijelić, G., Jorgovanović, N., Bojanić, D., Popović, M. B., & Popović, D. B.
- Venue
- Artificial Organs
- Publisher
- Wiley
- Published
- 2005-05-31
- Volume
- 29
- Issue
- 6
- Pages
- 448-452
- ISSN
- 0160-564X (ISSN-L)
- 1525-1594
- OpenAlex
- W2112941570
- Cited by
- 97
- References
- 0
- FWCI
- 1.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multi‐Field Surface Electrode for Selective Electrical Stimulation. https://app.cochat.ai/papers/10.1111/j.1525-1594.2005.29075.x
- The paper
- Popović‐Bijelić, A., Bijelić, G., Jorgovanović, N., Bojanić, D., Popović, M. B., & Popović, D. B. (2005). Multi‐Field Surface Electrode for Selective Electrical Stimulation. Artificial Organs. https://doi.org/10.1111/j.1525-1594.2005.29075.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.