CoChat

Electrical stimulation for the suppression of pathological tremor

Popović Maneski, Lana, Jorgovanović, Nikola, Ilić, Vojin, Došen, Strahinja, Keller, Thierry, Popović, Mirjana B., Popović, Dejan B. · 2011 · Medical & Biological Engineering & Computing

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

Pathological tremor is manifested as an involuntary oscillation of one or more body parts. Tremor greatly decreases the quality of life and often prevents the patient from performing daily activities. We hypothesized that sensors-driven multichannel electrical stimulation could stabilize affected joints by activating the antagonistic muscles during involuntary activation of agonist muscles and vice versa (out-of-phase stimulation). Here, we present the new system (hardware and software) and the testing of its operation. The hardware consists of a multichannel stimulator and inertial sensors for feedback. The software implements adaptive sensors-driven control for the out-of-phase stimulation. The system was initially applied to healthy persons at the wrist and elbow joints to test the efficiency of the hardware and software solutions. Predefined rhythmic stimulation resulted in tremulous movement, which subjects could not prevent; yet, they were still able to functionally use their hand. The system was then applied to seven patients with Parkinson's disease and essential tremor for minimization of the wrist joint tremor. In six patients, the adaptive out-of-phase stimulation resulted in a significant decrease in the amplitude of tremor (67 ± 13%). In one patient, the stimulation did not result in the expected reduction of tremor.

Overview

Integrity signals

Registry

Crossref · 10.1007/s11517-011-0803-6

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 20 references

Cited by

See all 130

Metadata

Authors
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B.
Affiliations
  • University of Novi Sad (RS)
  • Tecnalia (ES)
  • University of Belgrade (RS)
Venue
Medical & Biological Engineering & Computing
Published
2011-07-14
Volume
49
Issue
10
Pages
1187-1193
ISSN
  • 0140-0118 (ISSN-L)
  • 1741-0444
OpenAlex
W1995477441
Cited by
129
References
20
Citations by year
2026: 2 · 2025: 9 · 2024: 8 · 2023: 8 · 2022: 14 · 2021: 13 · 2020: 7 · 2019: 10 · 2018: 8 · 2017: 9 · 2016: 10 · 2015: 10 · 2014: 7 · 2013: 8 · 2012: 3
FWCI
4.26
Type
journal article
Language
en
Open access
closed
Licence
www.springer.com/tdm (tdm)
Locations
  • Medical & Biological Engineering & Computing (publishedVersion)
  • PubMed (publishedVersion)
  • TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
  • VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
Topics
  • Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
  • Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
Keywords
pathological tremor, electrical stimulation, inertial sensors, adaptive control, Parkinson's disease, essential tremor, tremor suppression
MeSH terms
Adult, Aged, Electric Stimulation Therapy, Equipment Design, Female, Humans, Male, Middle Aged, Parkinson Disease, Software Design, Tremor, Treatment Outcome, Upper Extremity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electrical stimulation for the suppression of pathological tremor. https://app.cochat.ai/papers/10.1007/s11517-011-0803-6
The paper
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011). Electrical stimulation for the suppression of pathological tremor. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-011-0803-6

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.