Electrical stimulation for the suppression of pathological tremor
The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
Pathological tremor is manifested as an involuntary oscillation of one or more body parts. Tremor greatly decreases the quality of life and often prevents the patient from performing daily activities. We hypothesized that sensors-driven multichannel electrical stimulation could stabilize affected joints by activating the antagonistic muscles during involuntary activation of agonist muscles and vice versa (out-of-phase stimulation). Here, we present the new system (hardware and software) and the testing of its operation. The hardware consists of a multichannel stimulator and inertial sensors for feedback. The software implements adaptive sensors-driven control for the out-of-phase stimulation. The system was initially applied to healthy persons at the wrist and elbow joints to test the efficiency of the hardware and software solutions. Predefined rhythmic stimulation resulted in tremulous movement, which subjects could not prevent; yet, they were still able to functionally use their hand. The system was then applied to seven patients with Parkinson's disease and essential tremor for minimization of the wrist joint tremor. In six patients, the adaptive out-of-phase stimulation resulted in a significant decrease in the amplitude of tremor (67 ± 13%). In one patient, the stimulation did not result in the expected reduction of tremor.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Of the above systems, several were demonstrated with individuals with tremor [17–20, 27–32] resulting in ~ 20–88% tremor attenuation levels”
From Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor (2019) · cites this paper as [30]
In the citing paper
“This system was tested on seven patients (three ET and four PD); although one of them did not respond to the stimulation, the remaining six showed an average tremor suppression of 67.0 ± 13.0%.”
From A Review on Wearable Technologies for Tremor Suppression (2021) · cites this paper as [66]
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 1×
“A tremor is an involuntary, rhythmic oscillation of a body part [4].”
BackgroundMechanism of action of deep brain stimulation.
Benazzouz, A., & Hallett, M. (2000) · PubMed · Cited by 350
Design and Validation of a Rehabilitation Robotic Exoskeleton for Tremor Assessment and Suppression
Rocon, E., Belda-Lois, J. M., Ruiz, A. F., Manto, M., Moreno, J. C., & Pons, J. L. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.903917 · Cited by 349 · cited 1×
“It has been shown that tremor can be mechanically suppressed using external skeletons in form of anthropomorphic robots [16, 17].”
BackgroundAttenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150 · cited 1×
“The first FES system that was designed to suppress tremor was proposed 20 years ago [6, 15 ].”
MethodTremor disorders. Diagnosis and management.
Anouti, A., & Koller, W. C. (1995) · PubMed Central · Cited by 135
Malešević, N., Popović‐Maneski, L., Schwirtlich, L. B., & Popović, D. B. (2010) · Muscle & Nerve · doi:10.1002/mus.21736 · Cited by 124
Self-citationMulti‐Field Surface Electrode for Selective Electrical Stimulation
Popović‐Bijelić, A., Bijelić, G., Jorgovanović, N., Bojanić, D., Popović, M. B., & Popović, D. B. (2005) · Artificial Organs · doi:10.1111/j.1525-1594.2005.29075.x · Cited by 97
Self-citationAttenuation of pathological tremors by functional electrical stimulation II: Clinical evaluation
Javidan, M., Elek, J., & Prochazka, A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368522 · Cited by 80 · cited 1×
“The first FES system that was designed to suppress tremor was proposed 20 years ago [6, 15].”
BackgroundAutomatic determination of the optimal shape of a surface electrode: Selective stimulation
Popović, D. B., & Popović, M. B. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.12.003 · Cited by 78
Self-citationMechanical suppression of essential tremor
Rocon, E., Manto, M., Pons, J., Camut, S., & Belda, J. M. (2007) · The Cerebellum · doi:10.1080/14734220601103037 · Cited by 68
Cited by
A multi-pad electrode based functional electrical stimulation system for restoration of grasp
Malešević, N. M., Maneski, L. Z., Ilić, V., Jorgovanović, N., Bijelić, G., Keller, T., & Popović, D. B. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-66 · Cited by 178
Self-citationBioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 183
Online tremor suppression using electromyography and low-level electrical stimulation
Dosen, S., Muceli, S., Dideriksen, J. L., Romero, J. P., Rocon, E., Pons, J., & Farina, D. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328296 · Cited by 120
Self-citationEvancho, A. M., Tyler, W. J., & McGregor, K. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1151218 · Cited by 111
Electrical stimulation of afferent pathways for the suppression of pathological tremor
Dideriksen, J. L., Laine, C. M., Dosen, S., Muceli, S., Rocon, E., Pons, J. L., Benito-Leon, J., & Farina, D. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00178 · Cited by 67
“…the use of external devices to suppress tremor by mechanical loading (Pledgie et al., 2000; Rocon et al., 2007) or electrical stimulation (Javidan et al., 1992; Prochazka et al., 1992; Gillard et al., 1999; Popović Maneski et al., 2011; Gallego et al., 2013; Bó et al., 2014; Dosen et al., 2015).”
BackgroundMethodSelf-citation
Metadata
- Authors
- Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B.
- Affiliations
- University of Novi Sad (RS)
- Tecnalia (ES)
- University of Belgrade (RS)
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2011-07-14
- Volume
- 49
- Issue
- 10
- Pages
- 1187-1193
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W1995477441
- Semantic Scholar
- 98ef177506afc865c5ce90349226e364b294c17b
- Cited by
- 129
- References
- 20
- Citations by year
- 2026: 2 · 2025: 9 · 2024: 8 · 2023: 8 · 2022: 14 · 2021: 13 · 2020: 7 · 2019: 10 · 2018: 8 · 2017: 9 · 2016: 10 · 2015: 10 · 2014: 7 · 2013: 8 · 2012: 3
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- TECNALIA Publications (Fundación TECNALIA Research & Innovation) (submittedVersion, public-domain)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Topics
- Health Sciences › Medicine › Clinical Neurology › Deep Brain Stimulation and Movement Disorders
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
- Keywords
- pathological tremor, electrical stimulation, inertial sensors, adaptive control, Parkinson's disease, essential tremor, tremor suppression
- MeSH terms
- Adult, Aged, Electric Stimulation Therapy, Equipment Design, Female, Humans, Male, Middle Aged, Parkinson Disease, Software Design, Tremor, Treatment Outcome, Upper Extremity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical stimulation for the suppression of pathological tremor. https://app.cochat.ai/papers/10.1007/s11517-011-0803-6
- The paper
- Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011). Electrical stimulation for the suppression of pathological tremor. Medical & Biological Engineering & Computing. https://doi.org/10.1007/s11517-011-0803-6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.