CoChat

Intra‐Aortic Balloon Counterpulsation in the Treatment of Infarction‐Related Cardiogenic Shock—Review of the Current Evidence

Buerke, Michael, Prondzinsky, Roland, Lemm, Henning, Dietz, Sebastian, Buerke, Ute, Ebelt, Henning, Bushnaq, Hasan, Silber, Rolf‐Edgar, Werdan, Karl · 2012 · Artificial Organs
Cited by 36

The DOI matches its Crossref record.

Abstract

The European ST‐elevated myocardial infarction (STEMI) guideline suggested the intra‐aortic balloon pump (IABP) with a recommendation level I and a level of evidence C as an effective measure in combination with balloon angioplasty in patients with cardiogenic shock (CS), stent implantation, and inotropic and vasopressor support. Similarly, upon mechanical complication due to myocardial infarction (MI), the guideline suggests that in patients with a ventricular septal defect or in most patients with acute mitral regurgitation, preoperative IABP implantation is indicated for circulatory support. The American College of Cardiology/American Heart Association STEMI guideline recommends the use of the IABP with a recommendation level I and a level of evidence B if CS does not respond rapidly to pharmacological treatment. The guideline notes that the IABP is a stabilizing measure for angiography and early revascularization. Even in MI complications, the use of preoperative IABP is recommended before surgery. Within this overview, we summarize the current evidence on IABP use in patients with CS complicated by MI. From our Cochrane data analysis, we conclude that in CS due to acute MI (AMI) treated with adjuvant systemic fibrinolysis, the IABP should be implanted. In patients with CS following AMI, treated with primary percutaneous coronary intervention (PCI), the IABP can be implanted, although data are not distinctive (i.e., indicating positive and negative effects). In the future, randomized controlled trials are needed to determine the use of IABP in CS patients treated with PCI. When patients with CS are transferred to a PCI center with or without thrombolysis, patients should receive mechanical support with an IABP. To treat mechanical MI complications—in particular ventricular septal defect—patients should be treated with an IABP to stabilize their hemodynamic situation prior to cardiac surgery. Similar recommendations are given in the German Austrian guidelines on treatment of infarction‐related CS patients (http://www.awmf.org/leitlinien/detail/ll/019‐013.html)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1525-1594.2011.01408.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 36

Metadata

Authors
Buerke, M., Prondzinsky, R., Lemm, H., Dietz, S., Buerke, U., Ebelt, H., Bushnaq, H., Silber, R., & Werdan, K.
Venue
Artificial Organs
Publisher
Wiley
Published
2012-05-21
Volume
36
Issue
6
Pages
505-511
ISSN
  • 0160-564X (ISSN-L)
  • 1525-1594
OpenAlex
W2125966821
Cited by
36
References
0
FWCI
2.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intra‐Aortic Balloon Counterpulsation in the Treatment of Infarction‐Related Cardiogenic Shock—Review of the Current Evidence. https://app.cochat.ai/papers/10.1111/j.1525-1594.2011.01408.x
The paper
Buerke, M., Prondzinsky, R., Lemm, H., Dietz, S., Buerke, U., Ebelt, H., Bushnaq, H., Silber, R., & Werdan, K. (2012). Intra‐Aortic Balloon Counterpulsation in the Treatment of Infarction‐Related Cardiogenic Shock—Review of the Current Evidence. Artificial Organs. https://doi.org/10.1111/j.1525-1594.2011.01408.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.