Summary: Purpose: We reviewed the literature to determine whether an analysis of published data could clarify the relationship between antiepileptic drug (AED) polytherapy and adverse affects (AE). We highlight the problems encountered. Methods: We made a Medline‐search for articles published between 1974 and 1994 reporting the number of AE and doses or serum levels of every AED, per patient or treatment group, and used the PDD/DDD ratio to calculate AED load per patient from doses or the OSL/AToxL ratio to do so from serum levels of individual drugs. The PDD/DDD is the sum of ratios of the actual prescribed daily doses divided by the published average therapeutic dose of each drug. The OSL/AToxL is the sum of each observed serum level divided by its average toxic level. Results: We retrieved 118 trial reports. Most had to be excluded because of incomplete reporting of concomitant medication or AE. The data of the 15 articles selected for further analysis indicate a relationship between drug load and number of AE. We noted no relationship between the number of AEDs administered and AE. In add‐on studies, the difference in neurotoxicity between the active and placebo arm may be obscured if the relative increase in drug load is small, as exemplified by the study of McGuire et al. (35). Conclusions: Articles reporting add‐on trials of new AEDs generally do not provide detailed information about the basic medication to which the new AED is added, which makes calculation of total drug load impossible. Furthermore, often only frequency of AE is reported, not severity or development of tolerance, making it difficult to judge the impact of AE. However, despite the paucity of available information, we present some evidence that toxicity in AED polytherapy may be related to total drug load, rather than to the number of drugs administered. Therefore, the present trend to reject polytherapy for fear of increased toxicity is not warranted, which removes one of the objections to initiating specific research to prove or disprove the value of AED combinations as long as the drug load is appropriate.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1528-1157.1997.tb01142.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 162

Metadata

Authors
Deckers, C. L. P., Hekster, Y. A., Keyser, A., Meinardi, H., & Renier, W. O.
Venue
Epilepsia
Publisher
Wiley
Published
1997-05
Volume
38
Issue
5
Pages
570-575
ISSN
  • 0013-9580 (ISSN-L)
  • 1528-1167
OpenAlex
W2120308827
Cited by
162
References
1
FWCI
3.54
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reappraisal of Polytherapy in Epilepsy: A Critical Review of Drug Load and Adverse Effects. https://app.cochat.ai/papers/10.1111/j.1528-1157.1997.tb01142.x
The paper
Deckers, C. L. P., Hekster, Y. A., Keyser, A., Meinardi, H., & Renier, W. O. (1997). Reappraisal of Polytherapy in Epilepsy: A Critical Review of Drug Load and Adverse Effects. Epilepsia. https://doi.org/10.1111/j.1528-1157.1997.tb01142.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.