The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Real‐Time Automated Detection and Quantitative Analysis of Seizures and Short‐Term Prediction of Clinical Onset
Abstract
Summary:Purpose:We describe an algorithm for rapid realtime detection, quantitation, localization of seizures, and prediction of their clinical onset. Methods:Advanced digital signal processing techniques used in time‐frequency localization, image processing, and identification of time‐varying stochastic systems were used to develop the algorithm, which operates in generic or adaptable “modes.” The “generic mode” was tested on (a) 125 partial seizures (each contained in a 10‐min segment) involving the mesial temporal regions and recorded using depth electrodes from 16 subjects, and (b) 205 ten‐minute segments of randomly selected interictal (nonseizure) data. The performance of the algorithm was compared with expert visual analysis, the current “gold standard.” Results:The generic algorithm achieved perfect sensitivity and specificity (no false‐positive and no false‐negative detections) over the entire data set. Seizure intensity, a novel measure that seems clinically relevant, ranged between 35.7 and 6129. Detection was sufficiently rapid to allow prediction of clinical onset in 92% of seizures by a mean of 15.5 s. Conclusions:This algorithm, which was implemented with a personal computer, represents a definitive step toward rapid and accurate detection and prediction of seizures. It may also enable development of intelligent devices for automated seizure warning and treatment and stimulate new study of the dynamics of seizures and of the epileptic brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Effects of Vagal Stimulation on Experimentally Induced Seizures in Rats
Woodbury, D. M., & Woodbury, J. W. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05852.x · Cited by 369
Cited by
Epileptic Seizures May Begin Hours in Advance of Clinical Onset
Litt, B., Esteller, R., Echauz, J., D'Alessandro, M., Shor, R., Henry, T., Pennell, P., Epstein, C., Bakay, R., Dichter, M., et al. (2001) · Neuron · doi:10.1016/s0896-6273(01)00262-8 · Cited by 641
Seizure prediction with spectral power of EEG using cost-sensitive support vector machines
Park, Y., Luo, L., Parhi, K. K., & Netoff, T. (2011) · Epilepsia · doi:10.1111/j.1528-1167.2011.03138.x · Cited by 398
Epileptic seizure prediction and control
Iasemidis, L. D. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.810705 · Cited by 363
Metadata
- Authors
- Osorio, I., Frei, M. G., & Wilkinson, S. B.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 1998-06
- Volume
- 39
- Issue
- 6
- Pages
- 615-627
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W1994024039
- Cited by
- 318
- References
- 2
- FWCI
- 5.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real‐Time Automated Detection and Quantitative Analysis of Seizures and Short‐Term Prediction of Clinical Onset. https://app.cochat.ai/papers/10.1111/j.1528-1157.1998.tb01430.x
- The paper
- Osorio, I., Frei, M. G., & Wilkinson, S. B. (1998). Real‐Time Automated Detection and Quantitative Analysis of Seizures and Short‐Term Prediction of Clinical Onset. Epilepsia. https://doi.org/10.1111/j.1528-1157.1998.tb01430.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.