Effects of Vagal Stimulation on Experimentally Induced Seizures in Rats
Abstract
Summary: Repetitive stimulation of the vagus nerve inhibits chemically induced seizures in dogs. We report here the results and conclusions from studies designed to answer some of the immediate questions raised by this finding. (1) Maximal stimulation of vagal C fibers at frequencies greater than 4 Hz prevents or reduces chemically and electrically induced seizures in young male rats. (2) Antiepileptic potency is directly related to the fraction of vagal C fibers stimulated. (3) Vagal stimulation shortens but does not shut down a chemical seizure once it has begun. (4) In rats, optimal stimulus frequency is approximately 10–20 Hz; duration of stimulus, 0.5‐1 ms; and stimulus strength, 0.2‐0.5 mA/mm 2 of nerve cross‐section. These results, when taken together with similar results obtained from dogs, monkeys, and humans, strongly suggest that periodic stimulation of the vagus nerve using appropriate stimulation parameters is a powerful method for preventing seizures. The data from the literature suggest that the antiepileptic actions of vagal stimulation are largely mediated by widespread release of GAB A and glycine in the brainstem and cerebral cortex. The probable pathway is via projections from the nucleus of the solitary tract to the reticular formation and thence by diffuse projections to the cortex and other areas. Intermittent vagal stimulation has the potentiality of reducing the number and/or the intensity of seizures in patients with intractable epilepsy. These results indicate that feasibility studies in humans should be continued and expanded.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Peripheral activation of vagal lung afferents, in theory, activates central parasympathetic representations and deactivates sympathetic-related regions and neurotransmitter systems at higher levels.
“such activation will, in theory, activate central parasympathetic representations and deactivate sympathetic-related regions and neurotransmitter systems at higher levels”
From Fear and the Defense Cascade (2015) · cites this paper as [150]
Cited by
Sorted by citations
Streeter, C. C., Gerbarg, P. L., Saper, R. B., Ciraulo, D. A., & Brown, R. P. (2012) · Medical Hypotheses · doi:10.1016/j.mehy.2012.01.021 · Cited by 694 · see citing works
Ben‐Menachem, E., Mañon‐Espaillat, R., Ristanovic, R., Wilder, B. J., Stefan, H., Mirza, W., Tarver, W. B., Wernicke, J. F., & First International Vagus Nerve Stimulation Study Group (1994) · Epilepsia · doi:10.1111/j.1528-1157.1994.tb02482.x · Cited by 683 · see citing works
Vagus-nerve stimulation for the treatment of epilepsy
Ben-Menachem, E. (2002) · The Lancet Neurology · doi:10.1016/s1474-4422(02)00220-x · Cited by 560 · see citing works
Prospective Long‐Term Study of Vagus Nerve Stimulation for the Treatment of Refractory Seizures
DeGiorgio, C. M., Schachter, S. C., Handforth, A., Salinsky, M., Thompson, J., Uthman, B., Reed, R., Collin, S., Tecoma, E., Morris, G. L., et al. (2000) · Epilepsia · doi:10.1111/j.1528-1157.2000.tb00325.x · Cited by 479 · see citing works
Kozlowska, K., Walker, P., McLean, L., & Carrive, P. (2015) · Harvard Review of Psychiatry · doi:10.1097/hrp.0000000000000065 · Cited by 468 · see citing works
Ben‐Menachem, E., Revesz, D., Simon, B. J., & Silberstein, S. (2015) · European Journal of Neurology · doi:10.1111/ene.12629 · Cited by 344 · see citing works
Vagus nerve stimulation: Surgical technique of implantation and revision and related morbidity
Giordano, F., Zicca, A., Barba, C., Guerrini, R., & Genitori, L. (2017) · Epilepsia · doi:10.1111/epi.13678 · Cited by 258 · see citing works
Role of the vagus nerve in the development and treatment of diet‐induced obesity
de Lartigue, G. (2016) · The Journal of Physiology · doi:10.1113/jp271538 · Cited by 238 · see citing works
Vagal nerve stimulation for treatment-resistant depression
Carreno, F. R., & Frazer, A. (2017) · Neurotherapeutics · doi:10.1007/s13311-017-0537-8 · Cited by 208 · see citing works
Considerations for Safety with Chronically Implanted Nerve Electrodes
Agnew, W. F., & McCreery, D. B. (1990) · Epilepsia · doi:10.1111/j.1528-1157.1990.tb05845.x · Cited by 184 · see citing works
Vagus Nerve Stimulation for Epilepsy and Depression
Milby, A. H., Halpern, C. H., & Baltuch, G. H. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.10.071 · Cited by 141 · see citing works
Furmaga, H., Shah, A., & Frazer, A. (2011) · Biological Psychiatry · doi:10.1016/j.biopsych.2011.07.020 · Cited by 116 · see citing works
Vagus nerve stimulation for intractable epilepsy: a review
McLachlan, R. S. (1997) · Journal of Clinical Neurophysiology · doi:10.1097/00004691-199709000-00002 · Cited by 89 · see citing works
Olofsson, P. S., Levine, Y. A., Caravaca, A., Chavan, S. S., Pavlov, V. A., Faltys, M., & Tracey, K. J. (2015) · Bioelectronic Medicine · doi:10.15424/bioelectronmed.2015.00006 · Cited by 81 · see citing works
Vagus nerve stimulation modulates hippocampal inflammation caused by continuous stress in rats
Namgung, U., Kim, K.-J., Jo, B.-G., & Park, J.-M. (2022) · Journal of Neuroinflammation · doi:10.1186/s12974-022-02396-z · Cited by 59 · see citing works
Clinical experience with a helical bipolar stimulating lead
TARVER, W. B., GEORGE, R. E., MASCHINO, S. E., HOLDER, L. K., & WERNICKE, J. F. (1992) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1992.tb02933.x · Cited by 46 · see citing works
Sackeim, H. A., Dibué, M., Bunker, M. T., & Rush, A. J. (2020) · Neuropsychiatric Disease and Treatment · doi:10.2147/ndt.s286977 · Cited by 15 · see citing works
Vagus nerve stimulation: Introduction and technical aspects
Pisapia, J., & Baltuch, G. (2015) · Neuromodulation in Psychiatry · doi:10.1002/9781118801086.ch17 · Cited by 11 · see citing works
- Authors
- Woodbury, D. M., & Woodbury, J. W.
- Affiliations
- University of Utah (US)
- Corresponding author
- Woodbury, Dixon M.
- Venue
- Epilepsia
- Publisher
- Wiley
- Published
- 1990-06
- Volume
- 31
- Issue
- s2
- Pages
- S7-19
- ISSN
- 0013-9580 (ISSN-L)
- 1528-1167
- OpenAlex
- W2059355906
- Cited by
- 369
- References
- 0
- Citations by year
- 2026: 2 · 2025: 11 · 2024: 13 · 2023: 11 · 2022: 15 · 2021: 10 · 2020: 15 · 2019: 12 · 2018: 15 · 2017: 10 · 2016: 13 · 2015: 22 · 2014: 10 · 2013: 13 · 2012: 15
- FWCI
- 4.81
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Epilepsia (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5k06ns013838-29)
- National Institute of Neurological Disorders and Stroke (5 KO6-NS-13838)
- Topics
- Life Sciences › Neuroscience › Neurology › Vagus Nerve Stimulation Research
- Health Sciences › Medicine › Psychiatry and Mental health › Epilepsy research and treatment
- Health Sciences › Medicine › Neurology › Neurological disorders and treatments
- Keywords
- vagus nerve stimulation, seizure prevention, antiepileptic effect, stimulation frequency, seizure induction, GABA release, glycine release, nucleus tractus solitarius, reticular formation, drug-resistant epilepsy
- MeSH terms
- Action Potentials, Animals, Electric Stimulation, Electric Stimulation Therapy, Heart Rate, Male, Neural Conduction, Neural Pathways, Pentylenetetrazole, Respiration, Seizures, Vagus Nerve, 3-Mercaptopropionic Acid, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review